Engineered for rigorous switching tasks, the Phoenix Contact REL-IR4/120AC/4X21/EX 2909744 PHOENIX CONTACT Single relay handles auxiliary load management and circuit isolation in automated processing facilities. These components are standard elements in control architectures, ensuring that changing logical states translate accurately into physical operations.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Type of electric connection (EF003961): Plug-in connection
- Complete with socket (EF003359): No
- With detachable clamps (EF003340): No
- With LED indication (EF005950): Yes
- Rated control supply voltage AC 50 Hz (EF003978): 93.6 V
- Rated control supply voltage AC 60 Hz (EF003979): 93.6 V
- Voltage type for actuating (EF008242): AC
- Drive, polarization (EF003355): Polarity free
- Drive, switching attitude (EF003356): Mono stable
- Number of contacts as normally closed contact (EF008255): 0
- Number of contacts as normally open contact (EF008256): 0
- Number of contacts as change-over contact (EF008257): 4
- Type of switch contact (EF003358): Single contact
- With forced-guided contacts (EF003357): No
- Material of contact surface (EF004020): Untreated
- Nominal current (EF000001): 0.013 A
More info
▲Key Commercial Data
| Orderkey | 2909744 |
|---|---|
| Packing unit | 10 pc |
| Note | Made to Order (non-returnable) |
| GTIN | 4055626379937 |
| Weight per Piece (excluding packing) | 34.800 g |
| Custom tariff number | 85364900 |
| Country of origin | PL (Poland) |
Ambient conditions
| Ambient temperature (operation) | -40 °C ... 55 °C |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Coil side
| Nominal input voltage UN | 120 V AC |
|---|---|
| Input voltage range in reference to UN | see diagram |
| Mains frequency | 50/60 Hz |
| Typical input current at UN | 13 mA |
| Typical response time | 5 ms ... 15 ms (depending on phase relation) |
| Typical release time range | 5 ms ... 20 ms (depending on phase relation) |
| Status display | Yellow LED |
| Power dissipation for nominal condition | 1.56 W |
Contact side
| Contact type | 4 PDTs |
|---|---|
| Type of switch contact | Single contact |
| Contact material | AgNi |
| Maximum switching voltage | 250 V AC/DC |
| Minimum switching voltage | 5 V (At 24 mA) |
| Min. switching current | 5 mA (at 24 V) |
| Maximum inrush current | 16 A (20 ms, N/O contact) |
| Limiting continuous current | 6 A |
| Interrupting rating (ohmic load) max. | 144 W (at 24 V DC) |
| 124 W (at 48 V DC) | |
| 108 W (at 60 V DC) | |
| 52 W (at 110 V DC) | |
| 48 W (at 220 V DC) | |
| 1500 VA (for 250 V AC) | |
| Switching capacity min. | 0.12 W |
| Switching capacity | 2 A (at 24 V, DC13) |
| 0.22 A (at 120 V, DC13) | |
| 0.11 A (at 250 V, DC13) | |
| 1.5 A (at 24 V, AC15) | |
| 1.5 A (at 120 V, AC15) | |
| 1 A (at 240 V, AC15) | |
| Switching capacity according to IEC 60947-5-1 | 2 A (at 24 V, DC13) |
| 0.22 A (at 120 V, DC13) | |
| 0.11 A (at 250 V, DC13) | |
| 1.5 A (at 24 V, AC15) | |
| 1.5 A (at 120 V, AC15) | |
| 1 A (at 240 V, AC15) | |
| Motor load according to UL 508 | 1/3 HP, 240 V AC |
General
| Test voltage relay winding/relay contact | 2.5 kVrms(50 Hz, 1 min.) |
|---|---|
| Test voltage PDT/PDT | 2 kVrms(50 Hz, 1 min.) |
| Operating mode | 100% operating factor |
| Degree of protection | RT III |
| Mechanical service life | approx. 2x 107cycles |
| Mounting position | any |
Standards and Regulations
| Standards/regulations | IEC 60664 |
|---|---|
| IEC 61810 | |
| Rated insulation voltage | 250 V AC |
| Rated surge voltage | 2.5 kV |
| Insulation | Basic insulation |
| Degree of pollution | 2 |
| Overvoltage category | II |
Environmental Product Compliance
| China RoHS | Environmentally Friendly Use Period = 50 |
|---|---|