View larger
REL-FO/L-24DC/2X21 1308296 PHOENIX CONTACT Plug-in miniature relay, FASTON connection, 2 switched contacts, ..
REL-FO/L-24DC/2X21
1308296
PHOENIX CONTACT
10 Pcs.
Automation > Switching relay
Industrial Relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Electromechanical relays such as the REL-FO/L-24DC/2X21 1308296 PHOENIX CONTACT Plug-in miniature relay, FASTON connection, 2 switched contacts provide reliable galvanic isolation and multi-circuit switching in heavy industrial automation equipment. They are regularly deployed to manage control signals, interlock machinery, and interface processor boards with external actuators.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- General: The outputs are not suitable for switching different outer conductors.
- Product type: Single relay
- Product family: ESSENTIAL edition
- Operating mode: 100% operating factor
- Mechanical service life: approx. 5x 10 7 cycles
- Relay type: Electromechanical relay
- Overvoltage category: II
- Pollution degree: 3
- Maximum power dissipation for nominal condition: 0.58 W
- Test voltage (Winding/contact): 5 kV rms (50 Hz, 1 min., winding/contact)
- Test voltage (Changeover contact/changeover contact): 3 kV rms (50 Hz, 1 min., changeover contact/changeover contact)
- Test voltage (): 1 kV rms (50 Hz, 1 min., open contact)
- Rated surge voltage: 2.5 kV
- Coil side Nominal input voltage U N: 24 V DC
- Input voltage range: 16.8 V DC ... 26.4 V DC
- Drive and function: monostable
More info
▲| General | Do not use to separate SELV/PELV circuits from other circuits, because safe isolation is not guaranteed. (applies to the optocoupler variants) |
| General | The outputs are not suitable for switching different outer conductors. |
| General | The system installer must ensure the touch protection of the product (at voltages > 25 V AC/60 V DC). The product is a built-in device without protection against direct contact. |
| Product type | Single relay |
| Product family | ESSENTIAL edition |
| Operating mode | 100% operating factor |
| Mechanical service life | approx. 5x 107cycles |
| Relay type | Electromechanical relay |
| Insulation characteristics: Air clearances and creepage distances between the power circuits | |
| Insulation | Basic insulation |
| Overvoltage category | II |
| Pollution degree | 3 |
| Maximum power dissipation for nominal condition | 0.58 W |
| Test voltage (Winding/contact) | 5 kVrms(50 Hz, 1 min., winding/contact) |
| Test voltage (Changeover contact/changeover contact) | 3 kVrms(50 Hz, 1 min., changeover contact/changeover contact) |
| Test voltage () | 1 kVrms(50 Hz, 1 min., open contact) |
| Air clearances and creepage distances between the power circuits | |
| Rated insulation voltage | 250 V AC |
| Rated surge voltage | 2.5 kV |
| Coil side | |
| Nominal input voltage UN | 24 V DC |
| Input voltage range | 16.8 V DC ... 26.4 V DC |
| Drive and function | monostable |
| Drive (polarity) | non-polarized |
| Typical input current at UN | 24 mA |
| Input power dissipation for UN | 0.58 W |
| Typical response time | 9 ms |
| Typical release time | 3 ms |
| Status display | Yellow LED |
| Coil resistance | 1080 Ω ±10 % |
| Switching | |
| Contact switching type | 2 changeover contacts |
| Type of switch contact | Single contact |
| Contact material | AgSnO |
| Maximum switching voltage | 250 V AC/DC |
| Minimum switching voltage | 5 V (10 mA) |
| Limiting continuous current | 8 A |
| Maximum inrush current | 16 A (20 ms, N/O contacts) |
| Min. switching current | 10 mA (5 V) |
| Interrupting rating (ohmic load) max. | 192 W (24 V DC) |
| 240 W (30 V DC) | |
| 2000 VA (250 V AC) | |
| Cross section AWG | (converted acc. to IEC) |
| Connection method | FASTON connection |
| Width | 13 mm |
| Height | 31.1 mm |
| Depth | 29 mm |
| Ambient conditions | |
| Degree of protection (Relay) | RT II (Relay) |
| Degree of protection (Installation location) | IP54 (Installation location) |
| Ambient temperature (operation) | -40 °C ... 70 °C |
| Ambient temperature (storage/transport) | -40 °C ... 70 °C |
| Altitude | ≤ 2000 m |
| Standards/regulations | IEC 61810-1 |
| IEC 60664-1 | |
| Air clearances and creepage distances between the power circuits | |
| Standards/regulations | IEC 60664-1 |
| Mounting position | any |