View larger
REL-FO/L-110DC/2X21 1308307 PHOENIX CONTACT Plug-in miniature relay, FASTON connection, 2 switched contacts,..
REL-FO/L-110DC/2X21
1308307
PHOENIX CONTACT
10 Pcs.
Automation > Switching relay
Industrial Relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A Phoenix Contact REL-FO/L-110DC/2X21 single relay is an electromechanical switching device utilized in industrial automation environments to isolate control circuits and manage secondary loads. This component interfaces low-level controller outputs with higher-voltage field instrumentation to ensure reliable sequential logic execution. Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- General: The outputs are not suitable for switching different outer conductors.
- Product type: Single relay
- Product family: ESSENTIAL edition
- Operating mode: 100% operating factor
- Mechanical service life: approx. 5x 10 7 cycles
- Relay type: Electromechanical relay
- Overvoltage category: II
- Pollution degree: 3
- Maximum power dissipation for nominal condition: 0.9 W
- Test voltage (Winding/contact): 5 kV rms (50 Hz, 1 min., winding/contact)
- Test voltage (Changeover contact/changeover contact): 3 kV rms (50 Hz, 1 min., changeover contact/changeover contact)
- Test voltage (): 1 kV rms (50 Hz, 1 min., open contact)
- Rated surge voltage: 2.5 kV
- Coil side Nominal input voltage U N: 110 V DC
- Input voltage range: 77 V DC ... 121 V DC
- Drive and function: monostable
More info
▲| General | Do not use to separate SELV/PELV circuits from other circuits, because safe isolation is not guaranteed. (applies to the optocoupler variants) |
| General | The outputs are not suitable for switching different outer conductors. |
| General | The system installer must ensure the touch protection of the product (at voltages > 25 V AC/60 V DC). The product is a built-in device without protection against direct contact. |
| Product type | Single relay |
| Product family | ESSENTIAL edition |
| Operating mode | 100% operating factor |
| Mechanical service life | approx. 5x 107cycles |
| Relay type | Electromechanical relay |
| Insulation characteristics: Air clearances and creepage distances between the power circuits | |
| Insulation | Basic insulation |
| Overvoltage category | II |
| Pollution degree | 3 |
| Maximum power dissipation for nominal condition | 0.9 W |
| Test voltage (Winding/contact) | 5 kVrms(50 Hz, 1 min., winding/contact) |
| Test voltage (Changeover contact/changeover contact) | 3 kVrms(50 Hz, 1 min., changeover contact/changeover contact) |
| Test voltage () | 1 kVrms(50 Hz, 1 min., open contact) |
| Air clearances and creepage distances between the power circuits | |
| Rated insulation voltage | 250 V AC |
| Rated surge voltage | 2.5 kV |
| Coil side | |
| Nominal input voltage UN | 110 V DC |
| Input voltage range | 77 V DC ... 121 V DC |
| Drive and function | monostable |
| Drive (polarity) | non-polarized |
| Typical input current at UN | 6 mA |
| Input power dissipation for UN | 0.66 W |
| Typical response time | 9 ms |
| Typical release time | 3 ms |
| Status display | Yellow LED |
| Coil resistance | 18870 Ω ±10 % |
| Switching | |
| Contact switching type | 2 changeover contacts |
| Type of switch contact | Single contact |
| Contact material | AgSnO |
| Maximum switching voltage | 250 V AC/DC |
| Minimum switching voltage | 5 V (10 mA) |
| Limiting continuous current | 8 A |
| Maximum inrush current | 16 A (20 ms, N/O contacts) |
| Min. switching current | 10 mA (5 V) |
| Interrupting rating (ohmic load) max. | 192 W (24 V DC) |
| 240 W (30 V DC) | |
| 2000 VA (250 V AC) | |
| Cross section AWG | (converted acc. to IEC) |
| Connection method | FASTON connection |
| Width | 13 mm |
| Height | 31.1 mm |
| Depth | 29 mm |
| Ambient conditions | |
| Degree of protection (Relay) | RT II (Relay) |
| Degree of protection (Installation location) | IP54 (Installation location) |
| Ambient temperature (operation) | -40 °C ... 70 °C |
| Ambient temperature (storage/transport) | -40 °C ... 70 °C |
| Altitude | ≤ 2000 m |
| Standards/regulations | IEC 61810-1 |
| IEC 60664-1 | |
| Air clearances and creepage distances between the power circuits | |
| Standards/regulations | IEC 60664-1 |
| Mounting position | any |