View larger
RC-19P1N124Z00 1602527 PHOENIX CONTACT Device connector, rear mounting
RC-19P1N124Z00
1602527
PHOENIX CONTACT
1 Pcs.
Cables > Circular connector, mounting (without cable)
Field Device Connectors (FDC)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Built for secure rear mounting, this Phoenix Contact RC-19P1N124Z00 1602527 PHOENIX CONTACT Device connector, rear mounting serves as a circular connector interface for industrial automation hardware. Circular device connectors are typically implemented to transmit power, data, or signals reliably between external cabling and internal enclosure electronics.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: Circular connectors (device side)
- Insulating body Coding: N
- Insertion/withdrawal cycles: 100
- Connection method: Solder cup
- Contact switching type: Pin
- Application: Signal
- Number of positions: 19
- Direction of rotation: Standard
- Connection profile: 16+3
- Contact diameter Power contacts: 1.5 mm
- Litz wire cross-section Power contacts min.: 0.08 mm²
- Litz wire cross-section Power contacts max.: 1 mm²
- Rated current Power contacts: 10 A
- Rated voltage: 48 V AC
- Rated surge voltage: 1.5 kV
- Overvoltage category: III
More info
▲| Product type | Circular connectors (device side) |
| Insulating body | |
| Coding | N |
| Insertion/withdrawal cycles | 100 |
| Connection method | Solder cup |
| Contact switching type | Pin |
| Application | Signal |
| Number of positions | 19 |
| Direction of rotation | Standard |
| Connection profile | 16+3 |
| Contact diameterPower contacts | 1.5 mm |
| Litz wire cross-sectionPower contactsmin. | 0.08 mm² |
| Litz wire cross-sectionPower contactsmax. | 1 mm² |
| Rated currentPower contacts | 10 A |
| Rated voltage | 48 V AC |
| 74 V DC | |
| Rated surge voltage | 1.5 kV |
| Overvoltage category | III |
| Degree of pollution | 3 |
| Contact diameterSignal contacts | 1 mm |
| Litz wire cross-sectionSignal contactsmin. | 0.08 mm² |
| Litz wire cross-sectionSignal contactsmax. | 1 mm² |
| Nominal current per signal contact | 8 A |
| Housing | |
| Order information: | Order contact inserts separately |
| Housing material | GD-Zn |
| Type of locking | Screw locking mechanism |
| Pg screw connection | none |
| Degree of protection (plugged in) | IP67 |
| Thread type | M23 |