Enclosure pass-throughs like the Phoenix Contact Q 1,5/2A50/11-M20KU-ESA panel feed-through allow safe conductor transition through metal housing walls. These connection modules maintain environmental separation while organizing internal and external wiring runs.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Product type: Panel feed-through
- Number of positions: 2
- Position marking: 1, 2
- Number of connections: 2
- Number of connections per position: 1
- Shielded: no
- Insulation characteristics Overvoltage category: III
- Degree of pollution: 3
- Connection technology Connection method On the device side: Single wires
- Conductor connection Conductor cross section flexibel: 0.75 mm² ... 1.5 mm²
- Conductor connection Conductor cross section solid: 0.75 mm² ... 1 mm²
- Connection cross section AWG: 18 ... 16
- Tightening torque Union nut: 2.5 Nm
- Tightening torque Contact carrier: 3.75 Nm
- Tightening torque Locking nut: 3.75 Nm
- Wrench size Union nut: 22 mm
More info
▲| Product type | Panel feed-through |
| Number of positions | 2 |
| Position marking | 1, 2 |
| Number of connections | 2 |
| Number of connections per position | 1 |
| Shielded | no |
| Insulation characteristics | |
| Overvoltage category | III |
| Degree of pollution | 3 |
| Connection technology | |
| Connection method On the device side | Single wires |
| Frequency of connections between conductors of the same cross section | 10 (if the conductor is connected more than once, seal and cap may need to be replaced.) |
| Conductor connection | |
| Conductor cross section flexibel | 0.75 mm² ... 1.5 mm² |
| Conductor cross section solid | 0.75 mm² ... 1 mm² |
| Connection cross section AWG | 18 ... 16 |
| Tightening torque Union nut | 2.5 Nm |
| Tightening torque Contact carrier | 3.75 Nm |
| Tightening torque Locking nut | 3.75 Nm |
| Wrench size Union nut | 22 mm |
| Wrench size Contact carrier | 22 mm |
| Pin assignment | |
| Contact Color (signal designation) Contact (optional) | 1 BN |
| 2 WH | |
| Dimensional drawing | |
| Width | 22 mm |
| Height | 22 mm |
| Length | 43.7 mm |
| Rated surge voltage (III/3) | 6 kV |
| Contact resistance | < 3 mΩ |
| rated voltage (II/2) | 630 V (with insulating sleeve) |
| rated voltage (III/2) | 320 V (with insulating sleeve) |
| Rated voltage (III/3) | 250 V (with insulating sleeve) |
| Nominal voltage UN | 250 V AC |
| 250 V DC | |
| Nominal current IN | 17.5 A |
| Color (Housing) | green (RAL 6021) |
| Material Housing | PA |
| Flammability rating according to UL 94 | V0 |
| Material wire insulation | PVC / PE |
| Contact material | Copper alloy |
| Contact surface material | Pre-nickel plated and tin-plated |
| Contact carrier material | PA 6.6 |
| Cable length | 0.5 m |
| Structure of individual litz in acc. with VDE 0295 / smallest wire diameter | VDE 0295 Cl.2-5, min. wire diameter 0.2 mm |
| Wire diameter including insulation | >= 3 mm |
| Position marking | 1, 2 |
| Cable cross section | 1.5 mm² |
| Mounting type | Front mounting M20 |
| Assembly note | If the conductor is reconnected, it must be cut off above the last contact point. QUICKON components may only be operated when under no load. |
| Ambient conditions | |
| Degree of protection | IP65 |
| IP67 | |
| Impact strength | IK06 |
| Ambient temperature (operation) | -25 °C ... 80 °C (Specifications of the cable manufacturer must be observed.) |
| -25 °C ... 50 °C (when the conductor is connected. Specifications of the cable manufacturer must also be observed.) | |
| Temperature when conductor connected | -5 °C ... 50 °C |