PHOENIX CONTACT AXL F DI8/2 48/60DC 1F AXL F DI8/2 48/60DC 1F 2702654 PHOENIX CONTACT I/O module View larger
Images are for illustrative purposes only. Please refer to data sheet for details

AXL F DI8/2 48/60DC 1F 2702654 PHOENIX CONTACT I/O module

AXL F DI8/2 48/60DC 1F

2702654

PHOENIX CONTACT

1 Pcs.

I/O module AxiolineF, Digital input module, Digital inputs: 8, 48 VDC / 60 VDC, connection technology: 2 conductors, corresponds to IEC 61850-3 standard, transmission speed on the local bus:100 MBit/s, protection index: IP20, including bus socket module and AxiolineF connectors Axioline F, Digital input module, Digital inputs: 8, 48 V DC / 60 V DC, connection technology: 2-conductor, corresponds to standard IEC 61850-3, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connectors

Automation > Fieldbus, decentr. periphery - digital I/O module
I/O

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

A Phoenix Contact I/O module, designated as part number AXL F DI8/2 48/60DC 1F, serves to acquire discrete field signals and integrate them into modular automation stations via a local bus network. Such devices provide high-speed data transmission for industrial sensor monitoring and machine control applications.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Width: 53.6 mm
  • Height: 126.1 mm
  • Depth: 54 mm
  • Note on dimensions: The depth applies when a TH 35-7.5 DIN rail is used (in accordance with EN 60715).
  • Note on application Note on application: Only for industrial use
  • Axioline F local bus Number of interfaces: 2
  • Connection method: Bus base module
  • Transmission speed: 100 Mbps
  • Module Input address area: 1 Byte
  • Output address area: 0 Byte
  • Required parameter data: 3 Byte
  • Required configuration data: 6 Byte
  • Digital: Input name: Digital inputs
  • Description of the input: EN 61131-2 type 1
  • Number of inputs: 8
  • Connection method: Push-in connection

More info

▲
Technical data

Dimensions
Dimensional drawing
Width53.6 mm
Height126.1 mm
Depth54 mm
Note on dimensionsThe depth applies when a TH 35-7.5 DIN rail is used (in accordance with EN 60715).

Notes
Note on application
Note on applicationOnly for industrial use

Interfaces
Axioline F local bus
Number of interfaces2
Connection methodBus base module
Transmission speed100 Mbps

System properties
Module
Input address area1 Byte
Output address area0 Byte
Required parameter data3 Byte
Required configuration data6 Byte

Input data
Digital:
Input nameDigital inputs
Description of the inputEN 61131-2 type 1
Number of inputs8
Connection methodPush-in connection
Connection technology2-conductor
Input voltage48 V (Nominal voltage)
60 V (Nominal voltage)
max. 100 V DC
Input voltage range-100 V DC ... 100 V DC
Input voltage range "0" signal-12 V DC ... 12 V DC
Input voltage range "1" signal32 V DC ... 100 V DC
Nominal input voltage UIN48 V DC
60 V DC
Nominal input current at UIN2.5 mA
Input filter time< 1 ms
Protective circuitPolarity reversal protection of the inputs

Product properties
Product typeI/O component
Product familyAxioline F
Typeblock modular
Mounting positionany (no temperature derating)
Nominal mounting position: wall mounting on horizontal DIN rail
Scope of deliveryincluding bus base module and Axioline F connectors
Special propertiescorresponds to standard IEC 61850-3
Data management status
Article revision01
Insulation characteristics
Overvoltage categoryIII (EN 61010-2-201/IEC 61010-2-201)
Pollution degree2

Electrical properties
Maximum power dissipation for nominal condition1.8 W
Potentials: Axioline F local bus supply (UBus)
Supply voltage5 V DC (via bus base module)
Current drawmax. 120 mA
Electrical isolation/isolation of the voltage ranges
Test voltage: I/Os / logic4 kV
5 kV
Test voltage: I/O/functional ground4 kV
5 kV
Test voltage: I/O / I/O (adjacent connectors)2.5 kV
Test voltage: Logic/functional ground1 kV

Connection data
Connection technology
Connection nameAxioline F connector
Note on the connection methodPlease observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Conductor connection
Connection methodPush-in connection
Conductor cross section rigid0.2 mm² ... 1.5 mm²
Conductor cross section flexible0.2 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Stripping length8 mm
Axioline F connector
Connection methodPush-in connection
Note on the connection methodPlease observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Conductor cross section, rigid0.2 mm² ... 1.5 mm²
Conductor cross section, flexible0.2 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Stripping length8 mm

Environmental and real-life conditions
Ambient conditions
Ambient temperature (operation)-25 °C ... 60 °C
Degree of protectionIP20
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)5 % ... 95 % (non-condensing)

Standards and regulations
Standard designationAmbient conditions
Standards/specificationsIEC 61850-3

Mounting
Mounting typeDIN rail mounting
Mounting positionany (no temperature derating)
Nominal mounting position: wall mounting on horizontal DIN rail

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.