PHOENIX CONTACT PTFIX 4X1,5-FE PTFIX 4X1,5-FE 1046620 PHOENIX CONTACT Distribution block, bridged internally, The blocks can be bridged wit.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

PTFIX 4X1,5-FE 1046620 PHOENIX CONTACT Distribution block, bridged internally, The blocks can be bridged wit..

PTFIX 4X1,5-FE

1046620

PHOENIX CONTACT

30 Pcs.

Distribution block, bridged internally, The blocks can be bridged with one another via the conductor shaft. For corresponding plug-in bridges, see accessories, nom. voltage: 450 V, nominal current: 17.5 A, connection method: Push-in connection, number of connections: 4, cross section: 0.14 mm² - 2.5 mm², AWG: 26 - 14, width: 8.3 mm, height: 17.7 mm, color: black/yellow, mounting type: for snapping onto a DIN rail adapter Distribution block, internally bridged, rated voltage: 450 V, rated current: 17.5 A, number of connections: 4, connection type: Push-in connection, cross-section: 0.14 mm² - 2.5 mm², mounting type: interlock in rail adapter, Direct mounting with a flange, Aerial, color: black/yellow Distribution block, bridged internally, nom. voltage: 450 V, nominal current: 17.5 A, number of connections: 4, connection method: Push-in connection, cross section: 0.14 mm2 - 2.5 mm2, mounting type: for snapping onto a DIN rail adapter, Direct mounting with flange, Free-hanging, color: black/yellow

Automation > Feed-through terminal block
FIX block System

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

The PTFIX 4X1,5-FE Phoenix Contact distribution block, bridged internally, provides a streamlined connection point for organizing sub-circuits and sensor lines within automation infrastructure. Modular distribution blocks eliminate messy wiring trees by offering pre-linked clamping units for fast potential distribution. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • General Note: The maximum load current of a single clamping unit must not be exceeded.
  • Product type: Distributor terminal block
  • Number of connections: 4
  • Number of rows: 1
  • Potentials: 1
  • Data management status Article revision: 03
  • Insulation characteristics Overvoltage category: III
  • Degree of pollution: 3
  • Rated surge voltage: 6 kV
  • Maximum power dissipation for nominal condition: 0.56 W
  • Number of connections per level: 4
  • Nominal cross section: 1.5 mm²
  • Rated cross section AWG: 14
  • Stripping length: 8 mm ... 10 mm
  • Internal cylindrical gage: A2 / B1
  • Connection in acc. with standard: IEC 60998-2-2

More info

▲
Technical data

Notes
Notes on operationthe blocks can be bridged with one another via the conductor shaft, for corresponding plug-in bridges, see accessories
General
NoteThe maximum load current of a single clamping unit must not be exceeded.

Product properties
Product typeDistributor terminal block
Number of connections4
Number of rows1
Potentials1
Data management status
Article revision03
Insulation characteristics
Overvoltage categoryIII
Degree of pollution3

Electrical properties
Rated surge voltage6 kV
Maximum power dissipation for nominal condition0.56 W

Connection data
Number of connections per level4
Nominal cross section1.5 mm²
Rated cross section AWG14
Stripping length8 mm ... 10 mm
Internal cylindrical gageA2 / B1
Connection in acc. with standardIEC 60998-2-2
Conductor cross section rigid0.14 mm² ... 2.5 mm²
Cross section AWG26 ... 14 (converted acc. to IEC)
Conductor cross section flexible0.14 mm² ... 1.5 mm²
Conductor cross section, flexible [AWG]26 ... 16 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve)0.14 mm² ... 1.5 mm²
Flexible conductor cross section (ferrule with plastic sleeve)0.14 mm² ... 1.5 mm²
Nominal current17.5 A
Maximum load current22 A
Maximum total current26 A
Nominal voltage450 V
Connection cross sections directly pluggable
Conductor cross section rigid0.34 mm² ... 2.5 mm²
Conductor cross section, rigid [AWG]26 ... 14 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve)0.34 mm² ... 1.5 mm²
Flexible conductor cross section (ferrule with plastic sleeve)0.34 mm² ... 1.5 mm²

Dimensions
Width8.3 mm
Height21.6 mm
Depth17.7 mm

Material specifications
Colormulticolored
black (RAL 9005)
yellow (RAL 1018)
Flammability rating according to UL 94V0
Insulating material groupI
Insulating materialPA
Static insulating material application in cold-60 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))125 °C
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3
Calorimetric heat release NFPA 130 (ASTM E 1354)27,5 MJ/kg
Surface flammability NFPA 130 (ASTM E 162)passed
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Smoke gas toxicity NFPA 130 (SMP 800C)passed

Electrical tests
Surge voltage test
ResultTest passed
Short-time withstand current 1.5 mm²0.18 kA
Short-time withstand current 2.5 mm²0.3 kA
ResultTest passed
Power-frequency withstand voltage
Test voltage setpoint1.89 kV
ResultTest passed

Mechanical properties
Mechanical data
Open side panelNo

Mechanical tests
Mechanical strength
ResultTest passed
Attachment on the carrier
DIN rail/fixing supportNS 35/NS 15
Test force setpoint1 N
ResultTest passed
NoteWhen aligning several blocks, it is recommended to either place a DIN rail adapter underneath the connection point or a flange element between the blocks.
For versions with 6 or 7 connections, it is enough to place one DIN rail adapter centrally per block and place flange elements after every other block.
When using the DIN rail adapter PTFIX-NS35, an aligned block must not protrude by more than a half.

Environmental and real-life conditions
Aging
Temperature cycles192
ResultTest passed
Needle-flame test
Time of exposure30 s
ResultTest passed
Oscillation/broadband noise
SpecificationDIN EN 50155 (VDE 0115-200):2018-05
SpectrumService life test category 2, bogie-mounted
Frequencyf1= 5 Hz to f2= 250 Hz
ASD level6.12 (m/s²)²/Hz
Acceleration3.12g
Test duration per axis5 h
Test directionsX-, Y- and Z-axis
ResultTest passed
Shocks
SpecificationDIN EN 50155 (VDE 0115-200):2018-05
Pulse shapeHalf-sine
Acceleration30g
Shock duration18 ms
Number of shocks per direction3
Test directionsX-, Y- and Z-axis (pos. and neg.)
ResultTest passed
Ambient conditions
Ambient temperature (operation)-60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.)
Ambient temperature (storage/transport)-25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C)
Ambient temperature (assembly)-5 °C ... 70 °C
Ambient temperature (actuation)-5 °C ... 70 °C
Permissible humidity (operation)20 % ... 90 %
Permissible humidity (storage/transport)30 % ... 70 %

Standards and regulations
Connection in acc. with standardIEC 60998-2-2

Mounting
Mounting typefor snapping onto a DIN rail adapter
Direct mounting with flange
Free-hanging

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.