View larger
PTFIX 4/18X1,5-NS35 YE 1047459 PHOENIX CONTACT Distribution block, nom. voltage: 500 V, nominal current: 17...
PTFIX 4/18X1,5-NS35 YE
1047459
PHOENIX CONTACT
20 Pcs.
Automation > Feed-through terminal block
FIX block System
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Phoenix Contact PTFIX 4/18X1,5-NS35 YE distribution block organizes power feeds by splitting a primary input into multiple managed output paths inside control cabinets. These compact modular blocks optimize space and reduce installation time across diverse automation infrastructures.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated voltage (EF000228): 500 V
- Number of clamp positions per level (EF002660): 19
- Mounting method (EF000003): DIN rail (top hat rail) 35 mm
- Width (EF000008): 21.6 mm
- Height (EF000040): 58.1 mm
- Depth (EF000049): 26.4 mm
- Closing plate required (EF002525): No
- Colour (EF000007): Yellow
- Internally connected stages (EF002661): Yes
More info
▲Key Commercial Data
| Orderkey | 1047459 |
|---|---|
| Packing unit | 1 pc |
| Minimum order quantity | 20 pc |
| Catalog page | Page 437 (C-1-2019) |
| GTIN | 4055626665641 |
| Weight per Piece (excluding packing) | 0.000 g |
| Custom tariff number | 85369010 |
| Country of origin | PL (Poland) |
General
| Number of levels | 1 |
|---|---|
| Number of connections | 19 |
| Nominal cross section | 1.5 mm² |
| Nominal cross section feed-in | 4 mm² |
| Color | yellow |
| Insulating material | PA |
| Flammability rating according to UL 94 | V0 |
| Rated surge voltage | 6 kV |
| Degree of pollution | 3 |
| Overvoltage category | III |
| Insulating material group | I |
| Maximum load current | 22 A (with a 2.5 mm² conductor cross section) |
| Maximum total current | 32 A |
| Nominal current IN | 17.5 A |
| Nominal voltage UN | 500 V |
| Maximum load current | 41 A (with 6 mm² conductor cross section) |
| Maximum total current | 41 A |
| Nominal current IN | 41 A |
| Open side panel | No |
Connection data
| Connection method | Push-in connection |
|---|---|
| Stripping length | 8 mm ... 10 mm |
| Connection in acc. with standard | IEC 60947-7-1 |
| Conductor cross section solid min. | 0.14 mm² |
| Conductor cross section solid max. | 2.5 mm² |
| Conductor cross section AWG min. | 26 |
| Conductor cross section AWG max. | 14 |
| Conductor cross section flexible min. | 0.14 mm² |
| Conductor cross section flexible max. | 1.5 mm² |
| Min. AWG conductor cross section, flexible | 26 |
| Max. AWG conductor cross section, flexible | 14 |
| Conductor cross section flexible, with ferrule without plastic sleeve min. | 0.14 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve max. | 1.5 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve min. | 0.14 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve max. | 1.5 mm² |
| Internal cylindrical gage | A3 |
| Connection | Feed-in stage |
| Connection method | Push-in connection |
| Stripping length | 10 mm ... 12 mm |
| Connection in acc. with standard | IEC 60998-2-2 |
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 6 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 10 |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 4 mm² |
| Min. AWG conductor cross section, flexible | 24 |
| Max. AWG conductor cross section, flexible | 10 |
| Conductor cross section flexible, with ferrule without plastic sleeve min. | 0.2 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve max. | 4 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve min. | 0.2 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve max. | 4 mm² |
Standards and Regulations
| Connection in acc. with standard | IEC 60947-7-1 |
|---|---|
| IEC 60998-2-2 | |
| Flammability rating according to UL 94 | V0 |