View larger
PTFIX 2X4 BK 1028367 PHOENIX CONTACT Block for distribution, Terminal base, rated voltage: 450 V, nominal cu..
PTFIX 2X4 BK
1028367
PHOENIX CONTACT
50 Pcs.
Automation > Feed-through terminal block
FIX block System
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The PTFIX 2X4 BK 1028367 PHOENIX CONTACT Block for distribution, Terminal base, rated voltage: 450 V, nominal cu.. acts as a centralized node for splitting incoming power supply lines to multiple secondary loads safely. Distribution terminal blocks streamline panel wiring by reducing jumper requirements and maintaining clean circuit organization. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product Type: Distribution terminal
- Number of connections: 2
- Number of rows: 1
- Data maintenance status Article review: 02
- Insulation characteristics Overvoltage Category: Iii
- Sizing Impulse Voltage: 8 kV
- Maximum power dissipation under nominal conditions: 1.02 W
- Number of connections per plan: 2
- Nominal cross-section: 4 mm²
- AWG Sizing Section: 12
- Length of the section to be stripped: 10 mm ... 12 mm
- Standard-compliant connection: IEC 60947-7-1
- Rigid conductor cross-section: 0.2 mm² ... 6 mm²
- Conductor cross-section AWG: 24 ... 10 (converted according to IEC)
- Flexible conductor cross-section: 0.2 mm² ... 4 mm²
- Flexible conductor cross-section [AWG]: 24 ... 12 (converted according to IEC)
More info
▲| Product Type | Distribution terminal |
| Number of connections | 2 |
| Number of rows | 1 |
| Data maintenance status | |
| Article review | 02 |
| Insulation characteristics | |
| Overvoltage Category | Iii |
| Sizing Impulse Voltage | 8 kV |
| Maximum power dissipation under nominal conditions | 1.02 W |
| Number of connections per plan | 2 |
| Nominal cross-section | 4 mm² |
| AWG Sizing Section | 12 |
| Length of the section to be stripped | 10 mm ... 12 mm |
| Standard-compliant connection | IEC 60947-7-1 |
| Rigid conductor cross-section | 0.2 mm² ... 6 mm² |
| Conductor cross-section AWG | 24 ... 10 (converted according to IEC) |
| Flexible conductor cross-section | 0.2 mm² ... 4 mm² |
| Flexible conductor cross-section [AWG] | 24 ... 12 (converted according to IEC) |
| Flexible conductor cross-section (cable lug without insulation collar) | 0.2 mm² ... 4 mm² |
| Flexible conductor cross-section (plastic lug and collar) | 0.2 mm² ... 4 mm² |
| 2 conductors of identical cross-section flexible with TWIN ferrule with plastic collar | 0.5 mm² ... 1 mm² |
| Rated current | 32 A |
| Maximum load current | 38 A (bei 6 mm² Leiterquerschnitt starr) |
| Maximum cumulative current | The maximum load current of the individual connection points must not be exceeded. |
| Nominal voltage | 800 V |
| note | IEC 60947-7-1 only applies to the use of fastening accessories. |
| Nominal cross-section | 4 mm² |
| Length of the section to be stripped | 10 mm ... 12 mm |
| Gauge Pad | A4 |
| Standard-compliant connection | IEC 60998-2-2 |
| Nominal voltage | 450 V (according to IEC 60998-2-2) |
| Plug-in direct connection cross-sections | |
| Rigid conductor cross-section | 0.5 mm² ... 6 mm² |
| Solid conductor cross-section [AWG] | 20 ... 10 (converted according to IEC) |
| Flexible conductor cross-section (cable lug without insulation collar) | 0.75 mm² ... 4 mm² |
| Flexible conductor cross-section (plastic lug and collar) | 0.5 mm² ... 4 mm² |
| width | 6.2 mm |
| height | 28.6 mm |
| Depth | 21.7 mm |
| Color | black (RAL 9005) |
| Combustibility class according to UL 94 | V0 |
| Insulation Material Group | The |
| Insulation material | PA |
| Cold static insulation material insert | -60 °C |
| Insulation Material Relative Temperature Index (Elec., UL 746 B) | 130 °C |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 |
| Surface Flammability NFPA 130 (ASTM E 162) | Exceeded |
| NFPA 130 (ASTM E 662) Specific Optical Density of Fumes | Exceeded |
| NFPA 130 Fume Toxicity (SMP 800C) | Exceeded |
| Impulse voltage test | |
| Test voltage rated value | 9.8 kV |
| Result | Test passed |
| Ambient Temperature Test | |
| Heating verification requirement | Temperature rise ≤ 45 K |
| Result | Test passed |
| Short-term current resistance 4 mm² | 0.48 kA |
| Short-term current resistance 6 mm² | 0.72 kA |
| Result | Test passed |
| Dielectric strength at mains frequency | |
| Test voltage rated value | 2 kV |
| Result | Test passed |
| Mechanical data | |
| Open side wall | no |
| Mechanical resistance | |
| Result | Test passed |
| Mounting on the stand | |
| Result | Test passed |
| note | For the placing of several blocks side by side, the feet must be positioned in such a way as to leave room for a maximum of 2 blocks. The flange elements should be positioned after every 6 blocks. |
| However, depending on the application case and mechanical load, other mounting accessory arrangements can also be selected. | |
| A PTFIX-NS35 DIN rail adapter is provided for up to 9 blocks. | |
| Conductor Integrity and Stability Test | |
| Rotational speed | 10 rpm |
| Turns | 135 |
| Conductor cross-section/weight | 0.2 mm2/0.2 kg |
| 4 mm2/0.9 kg | |
| 6 mm2/1.4 kg | |
| Result | Test passed |
| Aging | |
| Temperature Cycling | 192 |
| Result | Test passed |
| Needle flame test | |
| Duration of application | 30 s |
| Result | Test passed |
| Broadband vibration/noise | |
| Test Specification | DIN EN 50155 (VDE 0115-200):2008-03 |
| Spectrum | Category 2 Electrical Life Check, Trolley Mounted |
| Frequency | f1= 5 Hz up to f2= 250 Hz |
| ASD Level | 6.12 (m/s²)²/Hz |
| Acceleration | 3.12g |
| Test duration per axle | 5 h |
| Test Directions | X, Y, and Z axis |
| Result | Test passed |
| Shock | |
| Test Specification | DIN EN 50155 (VDE 0115-200):2008-03 |
| Shock Form | Semi-sinusoidal |
| Acceleration | 30g |
| Shock Duration | 18 ms |
| Number of shocks per direction | 3 |
| Test Directions | X, Y and Z axis (pos. and neg.) |
| Result | Test passed |
| Environmental conditions | |
| Ambient temperature (operating) | -60 °C ... 110 °C (Operating temperature range including self-heating, short-term maximum operating temperature cf. RTI Elec.) |
| Ambient temperature (storage/transport) | -25 °C ... 60 °C (for short duration, no longer than 24 h, -60 °C to +70 °C) |
| Ambient temperature (mounting) | -5 °C ... 70 °C |
| Ambient Temperature (Activation) | -5 °C ... 70 °C |
| Permissible humidity (operation) | 20 % ... 90 % |
| Permissible humidity (storage/transport) | 30 % ... 70 % |
| Standard-compliant connection | IEC 60947-7-1 |
| IEC 60998-2-2 |
| Mounting type | Mounting on adapters for mounting on a support rail |
| Direct flange mounting | |
| Mobile |