PTFIX 10/18X4 VT 3273916 PHOENIX CONTACT Block for distribution, rated voltage: 450 V, nominal current: 32 A..
PTFIX 10/18X4 VT
3273916
PHOENIX CONTACT
8 Pcs.
Automation > Feed-through terminal block
FIX block System
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Distributing incoming electrical power safely across multiple localized circuits is simplified with the Phoenix Contact PTFIX 10/18X4 VT (3273916) distribution terminal. These multi-port distribution blocks eliminate the need for traditional jumper systems by cleanly routing power feeds directly to numerous downstream devices. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- General Note: The maximum load current of the individual terminal point must not be exceeded.
- Product Type: Distribution terminal
- Number of ports: 19
- Number of rows: 1
- Potentials: 1
- Data maintenance status Article revision: 01
- Insulation properties Surge Category: III
- Degree of contamination: 3
- Rated Surge Voltage: 6 kV
- Maximum power dissipation at nominal condition: 1.02 W
- Feed-in: Yes
- Number of connections per floor: 19
- Nominal cross-section: 4 mm²
- Design cross-section AWG: 12
- Tapping Stripping length: 10 mm ... 12 mm
- Gauge Mandrel: A4
More info
▲| General | |
| Note | The maximum load current of the individual terminal point must not be exceeded. |
| For energy distribution applications, IEC 60364-4-43:2008, modified + Corrigendum Oct. 2008 (DIN VDE 0100-430:2010-10) Section 433.2 ff must be observed! | |
| Product Type | Distribution terminal |
| Number of ports | 19 |
| Number of rows | 1 |
| Potentials | 1 |
| Data maintenance status | |
| Article revision | 01 |
| Insulation properties | |
| Surge Category | III |
| Degree of contamination | 3 |
| Rated Surge Voltage | 6 kV |
| Maximum power dissipation at nominal condition | 1.02 W |
| Feed-in | Yes |
| Number of connections per floor | 19 |
| Nominal cross-section | 4 mm² |
| Design cross-section AWG | 12 |
| Tapping | |
| Stripping length | 10 mm ... 12 mm |
| Gauge Mandrel | A4 |
| Connection according to standard | IEC 60998-2-2 |
| Conductor cross-section rigid | 0.2 mm² ... 6 mm² |
| Conductor cross-section AWG | 24 ... 10 (converted to IEC) |
| Flexible conductor cross-section | 0.2 mm² ... 4 mm² |
| Conductor cross-section flexible [AWG] | 24 ... 12 (converted to IEC) |
| Flexible conductor cross-section (ferrule without plastic sleeve) | 0.2 mm² ... 4 mm² |
| Flexible conductor cross-section (ferrule with plastic sleeve) | 0.2 mm² ... 4 mm² |
| 2 conductors of the same cross-section flexible with TWIN ferrule with plastic sleeve | 0.5 mm² ... 1 mm² |
| Rated current | 32 A |
| Load current maximum | 41 A |
| Total current maximum | 63 A |
| Nominal voltage | 450 V |
| Hunt group | |
| Stripping length | 12 mm ... 14 mm |
| Connection according to standard | IEC 60998-2-2 |
| Conductor cross-section rigid | 0.5 mm² ... 10 mm² |
| Conductor cross-section AWG | 20 ... 6 (converted to IEC) |
| Flexible conductor cross-section | 0.5 mm² ... 10 mm² |
| Conductor cross-section flexible [AWG] | 20 ... 8 (converted to IEC) |
| Flexible conductor cross-section (ferrule without plastic sleeve) | 0.5 mm² ... 10 mm² |
| Flexible conductor cross-section (ferrule with plastic sleeve) | 0.5 mm² ... 10 mm² |
| Flexible conductor cross-section (2 conductors of the same cross-section with TWIN ferrule with plastic sleeve) | 0.5 mm² ... 4 mm² |
| 2 conductors of the same cross-section flexible with TWIN ferrule with plastic sleeve | 0.5 mm² ... 4 mm² |
| Rated current | 57 A |
| Load current maximum | 57 A |
| Nominal cross-section | 10 mm² |
| Tapping connection cross-sections can be plugged in directly | |
| Conductor cross-section rigid | 0.5 mm² ... 6 mm² |
| Conductor cross-section rigid [AWG] | 20 ... 10 (converted to IEC) |
| Flexible conductor cross-section (ferrule without plastic sleeve) | 0.75 mm² ... 4 mm² |
| Flexible conductor cross-section (ferrule with plastic sleeve) | 0.5 mm² ... 4 mm² |
| Connection cross-sections can be plugged in directly | |
| Conductor cross-section rigid | 0.5 mm² ... 16 mm² |
| Flexible conductor cross-section (ferrule without plastic sleeve) | 1 mm² ... 10 mm² |
| Flexible conductor cross-section (ferrule with plastic sleeve) | 1 mm² ... 10 mm² |
| Width | 64.8 mm |
| Height | 28.6 mm |
| Depth | 21.7 mm |
| Color | violet (RAL 4005) |
| Flammability class according to UL 94 | V0 |
| Insulating material group | I |
| Insulating material | PA |
| Static use of insulating material in cold conditions | -60 °C |
| Temperature Index Insulating Material (DIN EN 60216-1 (VDE 0304-21)) | 130 °C |
| Relative Insulating Temperature Index (Elec., UL 746 B) | 130 °C |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 |
| Heat Dissipation Calorimetric NFPA 130 (ASTM E 1354) | 28 MJ/kg |
| Surface Flammability NFPA 130 (ASTM E 162) | passed |
| Specific Optical Flue Gas Density NFPA 130 (ASTM E 662) | passed |
| Smoke gas toxicity NFPA 130 (SMP 800C) | passed |
| Mechanical data | |
| Open sidewall | Yes |
| Attachment to the carrier | |
| Result | Exam passed |
| Note | When stringing together several blocks, it is recommended to place a DIN rail adapter under the connection point or a flange element between the blocks. |
| For variants with 6 or 7 connections, it is sufficient to place a DIN rail adapter in the middle of each block and flange elements after every second block. | |
| When using the PTFIX-NS35 DIN rail adapter, a stacked block may only protrude a maximum of half. | |
| Needle Flame Testing | |
| Exposure time | 30 s |
| Result | Exam passed |
| Swing/Broadband Noise | |
| Test Specification | DIN EN 50155 (VDE 0115-200):2018-05 |
| Spectrum | Category 2 service life test, mounted on the bogie |
| Frequency | f1= 5 Hz to f2= 250 Hz |
| ASD Level | 6.12 (m/s²)²/Hz |
| Acceleration | 3.12g |
| Test duration per axis | 5 h |
| Test Directions | X, Y and Z axis |
| Result | Exam passed |
| Shock | |
| Test Specification | DIN EN 50155 (VDE 0115-200):2018-05 |
| Shock form | Half Sine |
| Acceleration | 30g |
| Shock duration | 18 ms |
| Number of shocks per direction | 3 |
| Test Directions | X, Y and Z axes (pos. and neg.) |
| Result | Exam passed |
| Environmental conditions | |
| Ambient temperature (operating) | -60 °C ... 110 °C (operating temperature range incl. self-heating, max. short-term operating temperature see RTI Elec.) |
| Ambient temperature (storage/transport) | -25 °C ... 60 °C (for a short time, not more than 24 h, -60 °C to +70 °C) |
| Ambient temperature (mounting) | -5 °C ... 70 °C |
| Ambient temperature (actuation) | -5 °C ... 70 °C |
| Permissible humidity (operating) | 20 % ... 90 % |
| Permissible humidity (storage/transport) | 30 % ... 70 % |
| Connection according to standard | IEC 60998-2-2 |
| IEC 60998-2-2 |
| Mounting type | Snap onto DIN rail adapter |
| Direct mounting with flange | |
| Flying |