PTFIX 10/18X4 BK 3273914 PHOENIX CONTACT Block for distribution, rated voltage: 450 V, nominal current: 32 A..
PTFIX 10/18X4 BK
3273914
PHOENIX CONTACT
8 Pcs.
Automation > Feed-through terminal block
FIX block System
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A Phoenix Contact PTFIX 10/18X4 BK block for distribution is utilized in control panel installations to split main power feeds into multiple auxiliary circuits safely and compactly. These distribution blocks reduce installation time and maintain clean conductor organization inside enclosures.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- General Observation: The maximum charging current of the various terminal points must not be exceeded.
- Product Type: Distribution terminal
- Number of connections: 19
- Number of rows: 1
- Potential: 1
- Data Maintenance Status Article Review: 01
- Insulation Properties Surge Category: Iii
- Degree of pollution: 3
- Dimensioning Transient Voltage: 6 kV
- Maximum Dissipated Power with Nominal Condition: 1.02 W
- Feeding: Yes
- Number of connections per floor: 19
- Nominal Section: 4 mm²
- AWG Sizing Section: 12
- Derivation Peel Length: 10 mm ... 12 mm
- Male Gauge: A4
More info
▲| General | |
| Observation | The maximum charging current of the various terminal points must not be exceeded. |
| For applications for power distribution, IEC 60364-4-43:2008 must be observed, as amended + correction Oct. 2008 (DIN VDE 0100-430:2010-10) part 433.2 et seq. | |
| Product Type | Distribution terminal |
| Number of connections | 19 |
| Number of rows | 1 |
| Potential | 1 |
| Data Maintenance Status | |
| Article Review | 01 |
| Insulation Properties | |
| Surge Category | Iii |
| Degree of pollution | 3 |
| Dimensioning Transient Voltage | 6 kV |
| Maximum Dissipated Power with Nominal Condition | 1.02 W |
| Feeding | Yes |
| Number of connections per floor | 19 |
| Nominal Section | 4 mm² |
| AWG Sizing Section | 12 |
| Derivation | |
| Peel Length | 10 mm ... 12 mm |
| Male Gauge | A4 |
| Standard-compliant connection | IEC 60998-2-2 |
| Rigid conductor section | 0.2 mm² ... 6 mm² |
| AWG Conductor Section | 24 ... 10 (Converted according to IEC) |
| Flexible conductor section | 0.2 mm² ... 4 mm² |
| Flexible Wire Section [AWG] | 24 ... 12 (Converted according to IEC) |
| Flexible cable section (toe cap without plastic sleeve) | 0.2 mm² ... 4 mm² |
| Flexible cable section (toe cap with plastic sleeve) | 0.2 mm² ... 4 mm² |
| 2 conductors with the same cross-section, flexible with TWIN toe cap with plastic sleeve | 0.5 mm² ... 1 mm² |
| Nominal current | 32 A |
| Maximum Charging Current | 41 A |
| Maximum Sum Current | 63 A |
| Nominal voltage | 450 V |
| Collective connection | |
| Peel Length | 12 mm ... 14 mm |
| Standard-compliant connection | IEC 60998-2-2 |
| Rigid conductor section | 0.5 mm² ... 10 mm² |
| AWG Conductor Section | 20 ... 6 (Converted according to IEC) |
| Flexible conductor section | 0.5 mm² ... 10 mm² |
| Flexible Wire Section [AWG] | 20 ... 8 (Converted according to IEC) |
| Flexible cable section (toe cap without plastic sleeve) | 0.5 mm² ... 10 mm² |
| Flexible cable section (toe cap with plastic sleeve) | 0.5 mm² ... 10 mm² |
| Flexible cable section (2 conductors with the same section with TWIN ferrule with plastic sleeve) | 0.5 mm² ... 4 mm² |
| 2 conductors with the same cross-section, flexible with TWIN toe cap with plastic sleeve | 0.5 mm² ... 4 mm² |
| Nominal current | 57 A |
| Maximum Charging Current | 57 A |
| Nominal Section | 10 mm² |
| Branch Directly pluggable connection section | |
| Rigid conductor section | 0.5 mm² ... 6 mm² |
| Rigid Wire Section [AWG] | 20 ... 10 (Converted according to IEC) |
| Flexible cable section (toe cap without plastic sleeve) | 0.75 mm² ... 4 mm² |
| Flexible cable section (toe cap with plastic sleeve) | 0.5 mm² ... 4 mm² |
| Collective connection Plug-in connection section | |
| Rigid conductor section | 0.5 mm² ... 16 mm² |
| Flexible cable section (toe cap without plastic sleeve) | 1 mm² ... 10 mm² |
| Flexible cable section (toe cap with plastic sleeve) | 1 mm² ... 10 mm² |
| Width | 64.8 mm |
| Height | 28.6 mm |
| Depth | 21.7 mm |
| Colour | black (RAL 9005) |
| Flammability class according to UL 94 | V0 |
| Insulating material group | I |
| Insulating material | PA |
| Static use of cold insulating material | -60 °C |
| Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) | 130 °C |
| Relative Insulating Material Temperature Index (Elec., UL 746 B) | 130 °C |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 |
| Heat Emission Calorimeter NFPA 130 (ASTM E 1354) | 28 MJ/kg |
| Flammability of NFPA 130 Surfaces (ASTM E 162) | approved |
| NFPA 130 Specific Optical Flue Gas Density (ASTM E 662) | approved |
| NFPA 130 Flue Gas Toxicity (SMP 800C) | approved |
| Mechanical data | |
| Open sidewall | No |
| Fixing on the bracket | |
| Result | Approved Test |
| Observation | If multiple blocks are arranged in a row, it is recommended to place a DIN rail adapter under the connection point or a flange element between the blocks. |
| In variants with 6 or 7 connections, it is sufficient to place a rail adapter in the centre for each block and a flange element for every two blocks. | |
| In case of use of the PTFIX-NS35 rail adapter, a maximum of half of a block can protrude in a row. | |
| Needle Flame Test | |
| Performance Time | 30 sec |
| Result | Approved Test |
| Broadband Oscillation/Noise | |
| Test Specification | DIN EN 50155 (VDE 0115-200):2018-05 |
| Spectrum | Category 2 durability test, on the bogie |
| frequency | f1= 5 Hz to f2= 250 Hz |
| ASD Level | 6.12 (m/s²)²/Hz |
| Acceleration | 3.12g |
| Test duration per axis | 5 h |
| Test Directions | X, Y, and Z axes |
| Result | Approved Test |
| Crash | |
| Test Specification | DIN EN 50155 (VDE 0115-200):2018-05 |
| Shock Type | Semi-sinusoid |
| Acceleration | 30g |
| Duration of the crash | 18 ms |
| Number of collisions per steering | 3 |
| Test Directions | X, Y, and Z axes (pos. and neg.) |
| Result | Approved Test |
| Environmental conditions | |
| Ambient Temperature (Service) | -60 °C ... 110 °C (Operating temperature range incl. self-heating, max. short-term operating temperature; see RTI Elec.) |
| Ambient Temperature (Storage/Transport) | -25°C ... 60 °C (For a short time, no more than 24 hours, from -60 °C to +70 °C) |
| Ambient Temperature (Mounting) | -5 °C ... 70 °C |
| Ambient Temperature (Drive) | -5 °C ... 70 °C |
| Permissible air humidity (service) | 20 % ... 90 % |
| Permissible air humidity (storage/transport) | 30 % ... 70 % |
| Standard-compliant connection | IEC 60998-2-2 |
| IEC 60998-2-2 |
| Type of mounting | Interlock in rail adapter |
| Direct mounting with a flange | |
| Aerial |