View larger
PTCB E1 24DC/0.63A SI-R 1464485 PHOENIX CONTACT Protection of single-channel electronic equipment for consum..
PTCB E1 24DC/0.63A SI-R
1464485
PHOENIX CONTACT
1 Pcs.
Automation > Device circuit breaker
Over Current Protection
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
PTCB E1 24DC/0.63A SI-R 1464485 PHOENIX CONTACT Protection of single-channel electronic equipment for consum.. functions as a single-channel electronic circuit protector designed to safeguard 24 V DC load circuits from overloads and short circuits. Electronic protection modules provide selective load protection to maintain uptime across complex industrial automation networks.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- type: Monolithic Rail Module
- Product Type: Electronic protection switch
- Product Family: PTCB
- No. of poles: 1
- Number of channels: 1
- Insulation characteristics Security class: Iii
- Degree of pollution: 2
- Number of channels: 1
- General notes Operating voltage: 10 V DC ... 30 V DC
- Nominal voltage: 24 V DC
- Dimension. I N: 15 A DC (Total Input Current)
- Rated Current I N: 0.63 A DC
- Rated current (preset): 0.63 A
- Sizing Impulse Voltage: 0.5 kV
- Release type: E (electronic)
- Return Feed Resistor: max. 35 V DC
More info
▲| General notes | |
| note | Connection for the controlled signal line according to EN 61000-4-4 with 1 kV; possibly provide for safety measures to be taken by the customer |
| Any repeated strong short circuits can reduce the melt integral of the integrated prefuse. | |
| type | Monolithic Rail Module |
| Product Type | Electronic protection switch |
| Product Family | PTCB |
| No. of poles | 1 |
| Number of channels | 1 |
| Insulation characteristics | |
| Security class | Iii |
| Degree of pollution | 2 |
| Number of channels | 1 |
| General notes | |
| Operating voltage | 10 V DC ... 30 V DC |
| Nominal voltage | 24 V DC |
| Dimension. IN | 15 A DC (Total Input Current) |
| 0.63 A DC (Rated Output Current) | |
| Rated Current IN | 0.63 A DC |
| Rated current (preset) | 0.63 A |
| Sizing Impulse Voltage | 0.5 kV |
| Release type | E (electronic) |
| Return Feed Resistor | max. 35 V DC |
| Prefuse required | Needed only if IMaxof the power supply > short-circuit breaking capacity. Integrated Fail-Safe element. |
| Short circuit breaking capacity | 300 A |
| Voltage resistance | max. 35 V DC (Load circuit) |
| Active current limitation | typ. 1.08 x IN |
| Fuse | electronic |
| Efficiency | > 98.5 % |
| Quiescent current I0 | tip. 3.8 mA |
| Power dissipation | tip. 0.1 W (No-load) |
| < 0.7 W (Rated Operation) | |
| Module initialization time | 40 ms |
| Wait time after a channel is deactivated | 5 s (overload / short circuit) |
| Measurement Tolerance I | ± 7 % |
| Temperature derating | 15 A (Total current at 60 °C) |
| 20 A (Total current at 50 °C) | |
| MTBF (IEC 61709, SN 29500) | 27034333 h (at 25 °C with 21 % load) |
| 11609008 h (at 40 °C at 34,25 % load) | |
| 1631800 h (at 60 °C at 100 % load) | |
| Dissipated voltage | 0.35 V (AT 0.63 A) |
| Fail-Safe Element | 4 A DC |
| Load circuit | |
| Cut-off time | ≤ 600 ms |
| ≥ 12 ms (Depending on available load) | |
| Disable tip. 1.08 x IN | |
| Undervoltage deactivation | ≤ 9.2 V DC (active) |
| ≥ 10.2 V DC (Idle) | |
| Overvoltage deactivation | ≥ 30.5 V DC (active) |
| ≤ 29.5 V DC (Idle) | |
| Max. capacitive load | 4.7 mF (Depending on current setting and available short-circuit current) |
| Reset | |
| Input voltage range | 7 V DC ... 30 V DC (Reset with falling edge) |
| Current consumption | tip. 0.4 mA (at 24 V DC) |
| Pulse length | ≥ 50 ms (High) |
| ≥ 50 ms (Low) | |
| tension | < 5 V DC (Low State) |
| > 8 V DC (High State) | |
| Stripping length | 8 mm |
| Rigid conductor cross-section | 0.2 mm² ... 2.5 mm² |
| Conductor cross-section AWG | 24 ... 12 |
| Flexible conductor cross-section with mounted lug and plastic collar | 0.25 mm² ... 2.5 mm² |
| Flexible conductor cross-section with cable lug without plastic collar | 0.25 mm² ... 2.5 mm² |
| Status Output | |
| Output voltage | 24 V DC (Error) |
| 0 V DC (No Error) | |
| Output current | max. 0.015 A (Short-circuit resistant) |
| Stripping length | 8 mm |
| Rigid conductor cross-section | 0.2 mm² ... 4 mm² |
| Conductor cross-section AWG | 24 ... 12 |
| Flexible conductor cross-section with mounted lug and plastic collar | 0.25 mm² ... 2.5 mm² |
| Flexible conductor cross-section with cable lug without plastic collar | 0.25 mm² ... 2.5 mm² |
| Conductor cross-section AWG | (converted according to IEC) |
| IN+ Main Circuit | |
| Link | Push-in connection |
| Stripping length | 8 mm |
| Flexible conductor cross-section | 0.2 mm² ... 2.5 mm² |
| Rigid conductor cross-section | 0.2 mm² ... 4 mm² |
| Conductor cross-section AWG | 24 ... 12 |
| Flexible conductor cross-section with mounted lug and plastic collar | 0.2 mm² ... 2.5 mm² |
| Flexible conductor cross-section with cable lug without plastic collar | 0.2 mm² ... 2.5 mm² |
| Main circuit IN- | |
| Link | Push-in connection |
| Stripping length | 8 mm |
| Flexible conductor cross-section | 0.2 mm² ... 2.5 mm² |
| Rigid conductor cross-section | 0.2 mm² ... 4 mm² |
| Conductor cross-section AWG | 24 ... 12 |
| Flexible conductor cross-section with mounted lug and plastic collar | 0.2 mm² ... 2.5 mm² |
| Flexible conductor cross-section with cable lug without plastic collar | 0.2 mm² ... 2.5 mm² |
| Main circuit OUT | |
| Link | Push-in connection |
| Stripping length | 8 mm |
| Flexible conductor cross-section | 0.2 mm² ... 2.5 mm² |
| Rigid conductor cross-section | 0.2 mm² ... 4 mm² |
| Conductor cross-section AWG | 24 ... 12 |
| Flexible conductor cross-section with mounted lug and plastic collar | 0.2 mm² ... 2.5 mm² |
| Flexible conductor cross-section with cable lug without plastic collar | 0.2 mm² ... 2.5 mm² |
| LED Channel Off | Off (Channel Off) |
| Yellow LED Channel | flashes (Active Programming Mode) |
| Green LED Channel | lights up (Channel On) |
| Red LED Channel | lights up (Channel off, overvoltage or undervoltage active) |
| Temporary light (Channel off, 5 s cooling phase, trip in case of overload or short circuit) | |
| flashes (Channel off, ready to rearm, trip in case of overload or short circuit) | |
| fast flashing (Channel off, external output voltage, possible installation error) |
| Dimensioned Drawing | |
| width | 6.2 mm |
| height | 105.8 mm |
| Depth | 55.6 mm (With 7.5 mm DIN rail) |
| Material | PBT |
| PBT | |
| Combustibility class according to UL 94 | V-0 |
| Environmental conditions | |
| Degree of protection | Ip20 |
| Ambient temperature (operating) | -30 °C ... 60 °C |
| Ambient temperature (storage/transport) | -40 °C ... 70 °C |
| Elevated position | ≤ 3000 m up to 52 °C (amsl) |
| ≤ 4000 m up to 46 °C (amsl) | |
| Moisture Proof | 96 h, 95 % RH, 40 °C |
| Shocks (exercise) | 30g (IEC 60068-2-27, Test Ea) |
| Vibration (exercise) | 10 Hz ... 59.6 Hz (Amplitude ± 0.35 mm; acc. to IEC 60068-2-6; Fc Test) |
| 59.6 Hz ... 150 Hz (5g acceleration; according to IEC 60068-2-6, Fc Test) | |
| 5 Hz ... 100 Hz (4g resonance search; 4g resonant frequency; 90 min according to DNV GL class B) | |
| UL Listed | |
| Marking | UL/C-UL Listed UL 508 |
| UL Recognized UL 2367 | |
| NEC Class 2 according to UL 1310 | |
| UL/C-UL Listed ANSI/UL 121201 Class I, Division 2, Groups A, B, C, D (Hazardous Location) | |
| DNV GL | |
| Marking | Approval for the naval sector |
| DNV GL data | |
| Temperatures | at |
| Humidity | b |
| Vibration | b |
| EMC | at |
| Enclosure | at |
| Standards/Regulations | EN 61000-6-2 |
| note | EMC - Noise Immunity for Industrial Environments |
| Standards/Regulations | EN 61000-6-3 |
| note | EMC - Noise Emission for Residential, Commercial and Light Industrial Environments |
| Standards/Regulations | EN 60068-2-78 |
| note | Environmental influences - Humidity and heat, constant |
| Standards/Regulations | EN 50178 |
| note | Electronic equipment for use in power installations |
| Standards/Regulations | EN 60068-2-6 |
| note | Environmental influences - Vibrations (sinusoidal) |
| Standards/Regulations | EN 60068-2-27 |
| note | Environmental influences - Shocks |
| Standards/Regulations | EN 60068-2-30 |
| note | Environmental influences - Part 2-30: Test methods - test Db: moist heat, cyclically |
| Mounting type | Support rail: 35 mm |