View larger
PT 4-HESI (5X20) GY/GY 1058940 PHOENIX CONTACT Fuse modular terminal block
PT 4-HESI (5X20) GY/GY
1058940
PHOENIX CONTACT
50 Pcs.
Automation > Fuse terminal block
Modular TBs
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
PT 4-HESI (5X20) GY/GY 1058940 PHOENIX CONTACT Fuse modular terminal block functions as a critical disconnect and protection point within complex control panel layouts. Panel builders rely on this hardware to distribute power efficiently while isolating sensitive instrumentation branches from unexpected surges or overloads. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Connectable conductor cross section solid-core (EF007337): 0.2 mm²
- Rated current In (EF008250): 6.3 A
- Rated voltage (EF000228): 500 V
- Number of levels (EF002659): 1
- Mounting method (EF000003): DIN rail (top hat rail) 35 mm
- Width (EF000008): 6.15 mm
- Height (EF000040): 55.9 mm
- Depth (EF000049): 63.393128 mm
- Closing plate required (EF002525): Yes
- Colour (EF000007): Grey
More info
▲Key Commercial Data
| Orderkey | 1058940 |
|---|---|
| Packing unit | 50 pc |
| Minimum order quantity | 50 pc |
| GTIN | 4055626702353 |
| Weight per Piece (excluding packing) | 13.520 g |
| Custom tariff number | 85369095 |
| Country of origin | PL (Poland) |
General
| Note | The current is determined by the fuse used, the voltage by the light indicator. |
|---|---|
| Number of levels | 1 |
| Number of connections | 2 |
| Nominal cross section | 4 mm² |
| Color | gray |
| Insulating material | PA |
| Flammability rating according to UL 94 | V0 |
| Area of application | Railway industry |
| Machine building | |
| Plant engineering | |
| Maximum power dissipation for nominal condition | 1.02 W |
| Fuse | G / 5 x 20 |
| Fuse type | Glass / ceramics / ... |
| Rated surge voltage | 6 kV |
| Degree of pollution | 3 |
| Overvoltage category | III |
| Insulating material group | I |
| Maximum power dissipation | max. 1.6 W (With single arrangement of the fuse terminal block in the event of overload) |
| max. 1.6 W (With interconnected arrangement of several fuse terminal blocks in the event of overload) | |
| max. 4 W (With single arrangement of the fuse terminal block in the event of a short-circuit) | |
| max. 2.5 W (With interconnected arrangement of several fuse terminal blocks in the event of a short-circuit) | |
| Connection in acc. with standard | IEC 60947-7-3 |
| Maximum load current | 6.3 A (the current is determined by the fuse used) |
| Nominal current IN | 6.3 A (the current is determined by the fuse used) |
| Nominal voltage UN | 500 V |
| Open side panel | Yes |
Connection data
| Conductor cross section solid min. | 0.2 mm² |
|---|---|
| Conductor cross section solid max. | 6 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 4 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 10 |
| Conductor cross section flexible, with ferrule without plastic sleeve min. | 0.25 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve max. | 4 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve min. | 0.25 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve max. | 4 mm² |
| 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, min. | 0.5 mm² |
| 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max. | 1 mm² |
| Connection method | Push-in connection |
| Stripping length | 10 mm ... 12 mm |
| Internal cylindrical gage | A4 |
Standards and Regulations
| Connection in acc. with standard | IEC 60947-7-3 |
|---|---|
| Flammability rating according to UL 94 | V0 |
Environmental Product Compliance
| China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
|---|---|
| No hazardous substances above threshold values |