View larger
PT 2,5-QUATTRO-DIO/L-R OG 3210271 PHOENIX CONTACT Component terminal block
PT 2,5-QUATTRO-DIO/L-R OG
3210271
PHOENIX CONTACT
50 Pcs.
Automation > Component terminal block
Modular TBs
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Engineered for high-density wiring configurations, the Phoenix Contact PT 2,5-QUATTRO-DIO/L-R OG component terminal block supports organized signal distribution and circuit isolation in industrial automation setups. DIN rail terminal blocks help streamline complex control panels by maintaining structured and accessible connection points. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Connectable conductor cross section solid-core (EF007337): 0.14 mm²
- Rated current In (EF008250): 0.5 A
- Rated voltage (EF000228): 800 V
- Number of levels (EF002659): 1
- Number of clamp positions per level (EF002660): 4
- Internally connected stages (EF002661): Yes
- Mounting method (EF000003): DIN rail (top hat rail) 35 mm
- Width (EF000008): 5.2 mm
- Height (EF000040): 72 mm
- Depth (EF000049): 35.3 mm
- Closing plate required (EF002525): Yes
- Colour (EF000007): Orange
More info
▲Key Commercial Data
| Orderkey | 3210271 |
|---|---|
| Packing unit | 50 pc |
| Minimum order quantity | 50 pc |
| Note | Made to Order (non-returnable) |
| GTIN | 4046356913805 |
| Weight per Piece (excluding packing) | 10.710 g |
| Custom tariff number | 85369010 |
| Country of origin | PL (Poland) |
General
| Note | The max. current is determined by the diode. Installed: Diode 1N 4007, reverse voltage: 1300 V, maximum continuous current: 0.5 A. |
|---|---|
| Number of levels | 1 |
| Number of connections | 4 |
| Potentials | 1 |
| Nominal cross section | 2.5 mm² |
| Color | orange |
| Insulating material | PA |
| Flammability rating according to UL 94 | V0 |
| Rated surge voltage | 8 kV |
| Degree of pollution | 3 |
| Overvoltage category | III |
| Insulating material group | I |
| Maximum power dissipation for nominal condition | 0.77 W |
| Maximum load current | 0.5 A |
| Nominal current IN | 0.5 A |
| Nominal voltage UN | 800 V |
| Open side panel | Yes |
Connection data
| Connection method | Push-in connection |
|---|---|
| Conductor cross section solid min. | 0.14 mm² |
| Conductor cross section solid max. | 4 mm² |
| Conductor cross section AWG min. | 26 |
| Conductor cross section AWG max. | 12 |
| Conductor cross section flexible min. | 0.14 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Min. AWG conductor cross section, flexible | 26 |
| Max. AWG conductor cross section, flexible | 14 |
| Conductor cross section flexible, with ferrule without plastic sleeve min. | 0.14 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve max. | 2.5 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve min. | 0.14 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve max. | 2.5 mm² |
| 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max. | 0.5 mm² |
| Stripping length | 8 mm ... 10 mm |
| Internal cylindrical gage | A3 |