PT 2,5-FE 1077080 PHOENIX CONTACT Terminal step, nominal voltage: 800 V, nominal current: 24 A, type of Conn..
PT 2,5-FE
1077080
PHOENIX CONTACT
50 Pcs.
Automation > Feed-through terminal block
Modular TBs
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A Phoenix Contact PT 2,5-FE terminal step acts as a fundamental feed-through connection point for routing conductors within control cabinets. Standard feed-through blocks are universally employed in automation engineering to connect, extend, or transition wire paths securely. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product Type: Feed-through clamp
- Scope of application: Railway industry
- Number of poles: 1
- Number of ports: 2
- Number of rows: 1
- Potentials: 1
- Data maintenance status Article revision: 04
- Insulation properties Surge Category: III
- Degree of contamination: 3
- Rated Surge Voltage: 8 kV
- Maximum power dissipation at nominal condition: 0.77 W
- Number of connections per floor: 2
- Nominal cross-section: 2.5 mm²
- Stripping length: 8 mm ... 10 mm
- Gauge Mandrel: A3
- Connection according to standard: IEC 60947-7-1
More info
▲| Product Type | Feed-through clamp |
| Scope of application | Railway industry |
| Mechanical Engineering | |
| Plant construction | |
| Process industry | |
| Number of poles | 1 |
| Number of ports | 2 |
| Number of rows | 1 |
| Potentials | 1 |
| Data maintenance status | |
| Article revision | 04 |
| Insulation properties | |
| Surge Category | III |
| Degree of contamination | 3 |
| Rated Surge Voltage | 8 kV |
| Maximum power dissipation at nominal condition | 0.77 W |
| Number of connections per floor | 2 |
| Nominal cross-section | 2.5 mm² |
| Stripping length | 8 mm ... 10 mm |
| Gauge Mandrel | A3 |
| Connection according to standard | IEC 60947-7-1 |
| Conductor cross-section rigid | 0.14 mm² ... 4 mm² |
| Conductor cross-section AWG | 26 ... 12 (converted to IEC) |
| Flexible conductor cross-section | 0.14 mm² ... 4 mm² |
| Conductor cross-section flexible [AWG] | 26 ... 12 (converted to IEC) |
| Flexible conductor cross-section (ferrule without plastic sleeve) | 0.14 mm² ... 2.5 mm² |
| Flexible conductor cross-section (ferrule with plastic sleeve) | 0.14 mm² ... 2.5 mm² |
| 2 conductors of the same cross-section flexible with TWIN ferrule with plastic sleeve | 0.5 mm² |
| Rated current | 24 A (at 2.5 mm²) |
| Load current maximum | 28 A (rigid with a conductor cross-section of 4 mm²) |
| Nominal voltage | 800 V |
| Nominal cross-section | 2.5 mm² |
| Connection cross-sections can be plugged in directly | |
| Conductor cross-section rigid | 0.34 mm² ... 4 mm² |
| Flexible conductor cross-section (ferrule without plastic sleeve) | 0.5 mm² ... 2.5 mm² |
| Flexible conductor cross-section (ferrule with plastic sleeve) | 0.34 mm² ... 2.5 mm² |
| Design data (ATEX/IECEx) | |
| Marking | II 2 G Ex eb IIC Gb |
| Operational temperature range | -60 °C ... 110 °C |
| Ex-certified accessories | 3030417 D-ST 2.5 |
| 3030721 ATP-ST 4 | |
| 1204517 SZF 1-0.6X3.5 | |
| 3022276 CLIPFIX 35-5 | |
| 3022218 CLIPFIX 35 | |
| Listing Bridges | Jumper / FBS 2-5 / 3030161 |
| Jumper / FBS 3-5 / 3030174 | |
| Jumper / FBS 4-5 / 3030187 | |
| Jumper / FBS 5-5 / 3030190 | |
| Jumper / FBS 10-5 / 3030213 | |
| Jumper / FBS 20-5 / 3030226 | |
| Jumper / FBS 50-5 / 3038930 | |
| Bridging data | 19 A / 2.5 mm² |
| Temperature increase Ex | 40 K (19 A / 2.5 mm²) |
| Rated voltage | 550 V |
| in the case of a bridge with a bridge | 550 V |
| - in case of skipping bridging | 352 V |
| - for cut-to-length bridging | 220 V |
| - with cut-to-length bridge with lid | 275 V |
| - With cut-to-length bridge with compartment divider plate | 550 V |
| Rated insulation voltage | 500 V |
| Output | (permanent) |
| Floor Ex General | |
| Rated current | 19 A |
| Load current maximum | 23 A |
| Contact resistance | 0.93 mΩ |
| Connection Data Ex General | |
| Nominal cross-section | 2.5 mm² |
| Design cross-section AWG | 14 |
| Connection capacity rigid | 0.14 mm² ... 4 mm² |
| Connection capacity AWG | 26 ... 12 |
| Flexible connection capacity | 0.14 mm² ... 2.5 mm² |
| Connection capacity AWG | 26 ... 14 |
| Width | 5.2 mm |
| Lid width | 2.2 mm |
| Height | 48.5 mm |
| Depth | 35.3 mm |
| Depth on NS 35/7.5 | 36.8 mm |
| Depth on NS 35/15 | 44.3 mm |
| Color | multi-coloured |
| black (RAL 9005) | |
| yellow (RAL 1018) | |
| Flammability class according to UL 94 | V0 |
| Insulating material group | I |
| Insulating material | PA |
| Static use of insulating material in cold conditions | -60 °C |
| Relative Insulating Temperature Index (Elec., UL 746 B) | 130 °C |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 |
| Surface Flammability NFPA 130 (ASTM E 162) | passed |
| Specific Optical Flue Gas Density NFPA 130 (ASTM E 662) | passed |
| Smoke gas toxicity NFPA 130 (SMP 800C) | passed |
| Mechanical data | |
| Open sidewall | Yes |
| Environmental conditions | |
| Ambient temperature (operating) | -60 °C ... 110 °C (operating temperature range incl. self-heating, max. short-term operating temperature see RTI Elec.) |
| Ambient temperature (storage/transport) | -25 °C ... 60 °C (for a short time, not more than 24 h, -60 °C to +70 °C) |
| Ambient temperature (mounting) | -5 °C ... 70 °C |
| Ambient temperature (actuation) | -5 °C ... 70 °C |
| Permissible humidity (operating) | 20 % ... 90 % |
| Permissible humidity (storage/transport) | 30 % ... 70 % |
| Connection according to standard | IEC 60947-7-1 |
| Mounting type | NS 35/7,5 |
| NS 35/15 |