View larger
PSR-SPP-42-230UC/URM4/4NO/2NC 2702925 PHOENIX CONTACT Extension module
PSR-SPP-42-230UC/URM4/4NO/2NC
2702925
PHOENIX CONTACT
1 Pcs.
Automation > Device for monitoring of safety-related circuits
Safety
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Phoenix Contact PSR-SPP-42-230UC/URM4/4NO/2NC is an expansion module designed to extend the output contact capacity of primary safety relays in industrial automation networks. Expansion units allow a safety system to safely switch multiple auxiliary circuits simultaneously when a protective shutdown occurs.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Model (EF000010): Expansion device: Expansion device
- Suitable for rail mounting (EF003972): Yes: Yes
- With detachable clamps (EF003340): Yes: Yes
- Type of electric connection (EF003961): Spring clamp connection: Spring clamp connection
- Suitable for monitoring of valves (EF007272): No: No
- Suitable for monitoring of tactile sensors (EF007271): No: No
- Suitable for monitoring of magnetic switches (EF007266): No: No
- Suitable for monitoring of proximity switches (EF007267): No: No
- With muting function (EF004057): No: No
- With feedback circuit (EF003343): No: No
- Release-delay (EF001129): 0.1 s: 0.1 s
- With approval for BG BIA (EF004145): No: No
- With approval according to UL (EF001783): No: No
- Width (EF000008): 22.5 mm: 22.5 mm
- Height (EF000040): 112 mm: 112 mm
- Depth (EF000049): 114.5 mm: 114.5 mm
More info
▲Key Commercial Data
| Orderkey | 2702925 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 263 (C-6-2017) |
| GTIN | 4055626428895 |
| Weight per Piece (excluding packing) | 195.000 g |
| Custom tariff number | 85371098 |
| Country of origin | DE (Germany) |
Ambient conditions
| Ambient temperature (operation) | -20 °C ... 55 °C (observe derating) |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
| Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
| Maximum altitude | ≤ 2000 m (Above sea level) |
Input data
| Rated control circuit supply voltage US | 42 V AC/DC ... 230 V AC/DC -15 % ... +10 % (Rated control circuit supply voltage US) |
|---|---|
| Rated control supply current IS | typ. 35 mA (42 V DC) |
| typ. 15 mA (230 V AC) | |
| Power consumption at US | max. 1.5 W (with DC) |
| max. 1.7 W (with AC) | |
| Inrush current | < 38 A (Δt = 50 µs at Us) |
| Typ. starting time with Us | < 100 ms (when controlled via A1) |
| Typical release time | < 20 ms (Control via A1 at 42 V DC) |
| < 200 ms (Control via A1 at 230 V AC) | |
| Recovery time | < 1 s |
| Operating voltage display | 1 x green LED |
| Protective circuit | Surge protection Suppressor diode and varistors |
| Maximum switching frequency | 0.5 Hz |
Output data
| Contact type | 4 enabling current paths |
|---|---|
| 1 confirmation current path | |
| 1 signaling current path | |
| Contact material | AgSnO2 |
| Maximum switching voltage | 250 V AC/DC (Observe the load curve) |
| Minimum switching voltage | 5 V AC/DC |
| Limiting continuous current | 6 A (N/O contact, pay attention to the derating) |
| 1 A (N/C contact 51/52) | |
| 6 A (N/C contact 61/62) | |
| Maximum inrush current | 8 A |
| Inrush current, minimum | 10 mA |
| Sq. Total current | 72 A2(observe derating) |
| Interrupting rating (ohmic load) max. | 1500 VA (N/O contact, 250 V AC, τ = 0 ms) |
| For additional values, see load curve | |
| Maximum interrupting rating (inductive load) | 48 W (N/O contact, 24 V DC, τ = 40 ms) |
| 40 W (N/O contact, 48 V DC, τ = 40 ms) | |
| 36 W (N/O contact, 60 V DC, τ = 40 ms) | |
| 35 W (N/O contact, 110 V DC, τ = 40 ms) | |
| 33 W (N/O contact, 220 V DC, τ = 40 ms) | |
| 1500 VA (N/O contact, 250 V AC, τ = 40 ms) | |
| Switching capacity | min. 50 mW |
| Mechanical service life | 10x 106cycles |
| Switching capacity according to IEC 60947-5-1 | 5 A (24 V (DC13)) |
| 5 A (250 V (AC15)) | |
| Output fuse | 6 A gL/gG (N/O contact and N/C contact 61/62) |
| 4 A gL/gG (N/O contact and N/C contact 61/62 for low-demand applications) | |
| 1 A gL/gG (N/C contact 51/52) |
General
| Relay type | Electromechanical relay with forcibly guided contacts in accordance with EN 50205 |
|---|---|
| Nominal operating mode | 100% operating factor |
| Net weight | 195 g |
| Mounting position | vertical or horizontal |
| Mounting type | DIN rail mounting |
| Assembly instructions | See derating curve |
| Degree of protection | IP20 |
| Min. degree of protection of inst. location | IP54 |
| Housing material | PBT |
| Housing color | yellow |
Connection data
| Connection method | Spring-cage connection |
|---|---|
| pluggable | Yes |
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 1.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 1.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 16 |
| Stripping length | 8 mm |
Safety-related characteristic data
| Stop category | 0 |
|---|---|
| Designation | IEC 61508 - High demand |
| Safety Integrity Level (SIL) | 3 (In conjunction with suitable evaluating device) |
| Designation | IEC 61508 - Low demand |
| Safety Integrity Level (SIL) | 3 (In conjunction with suitable evaluating device) |
| Designation | EN ISO 13849 |
| Performance level (PL) | e (In conjunction with suitable evaluating device) |
| Category | 4 (In conjunction with suitable evaluating device) |
| Designation | EN 62061 |
| Safety Integrity Level Claim Limit (SIL CL) | 3 (In conjunction with suitable evaluating device) |
| Designation | EN 50156 |
| Safety Integrity Level (SIL) | 3 |
Standards and Regulations
| Designation | Air clearances and creepage distances between the power circuits |
|---|---|
| Standards/regulations | DIN EN 50178/VDE 0160 |
| Rated insulation voltage | 250 V AC |
| Rated surge voltage/insulation | Safe isolation, reinforced insulation 6 kV: between (A1/A2) and the remaining current paths between (51/52) and the remaining current paths between (61/62) and the remaining current paths between (13/14, 23/24, 33/34, 43/44) and the remaining current paths |
| 4 kV basic insulation between enabling current paths | |
| Basic insulation 4 kV between all current paths and housing | |
| Degree of pollution | 2 |
| Overvoltage category | III |
| Shock | 15g |
| Vibration (operation) | 10 Hz ... 150 Hz, 2g |
| Conformance | CE-compliant |
Environmental Product Compliance
| REACh SVHC | Lead 7439-92-1 |
|---|---|
| China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
| No hazardous substances above threshold values |