View larger
PSR-SPP- 24DC/URM4/5X1/2X2/B 1442342 PHOENIX CONTACT Extension of 1 or 2 channel contacts, 5 normally open c..
PSR-SPP-24DC/URM4/5X1/2X2/B
1442342
PHOENIX CONTACT
1 Pcs.
Automation > Device for monitoring of safety-related circuits
Safety
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Expand safety circuit capabilities using the Phoenix Contact PSR-SPP-24DC/URM4/5X1/2X2/B safety relay, designed to multiply contact paths for emergency stops and protective doors. These expansion modules ensure reliable signal transmission and fault monitoring in automated machine safety architectures. Pricing, stock availability, and lead times are verified per enquiry.
- Product Type: Safety Relay
- Product Family: PSRclassic
- application: Expansion module
- Mechanical service life: 10x 10 6 operations
- Relay Type: Electromechanical relay with forced conduction contacts according to IEC/EN 61810-3
- Times Typical Excitation Time with U s: < 25 ms (with Us/with excitation via A1)
- Typical Opening Time: < 20 ms (with Us/with excitation via A1)
- Recovery Time: < 1 sec
- Nominal Operating Type: Working time 100%
- Sizing/Insulation Transient Voltage: See the chapter Coordination of insulations
- Digital: A1 Ticket Description: Safety-oriented
- Number of Entries: 1
- Input Voltage Range Signal "1": 19.2 V ... 26.4 V
- Total permissible line resistance max.: 25 Ω
- Protection Circuit: Suppressor diode
- Current absorption: Typ. 75 mA
More info
▲| Product Type | Safety Relay |
| Product Family | PSRclassic |
| application | Expansion module |
| Mechanical service life | 10x 106operations |
| Relay Type | Electromechanical relay with forced conduction contacts according to IEC/EN 61810-3 |
| Times | |
| Typical Excitation Time with Us | < 25 ms (with Us/with excitation via A1) |
| Typical Opening Time | < 20 ms (with Us/with excitation via A1) |
| Recovery Time | < 1 sec |
| Nominal Operating Type | Working time 100% |
| Creepage lines and air gaps between circuits | |
| Sizing Insulation Voltage | 250 V |
| Sizing/Insulation Transient Voltage | See the chapter Coordination of insulations |
| Digital: A1 | |
| Ticket Description | Safety-oriented |
| Number of Entries | 1 |
| Input Voltage Range Signal "1" | 19.2 V ... 26.4 V |
| Total permissible line resistance max. | 25 Ω |
| Protection Circuit | Suppressor diode |
| Current absorption | Typ. 75 mA |
| Relay: Trip circuits (23/24 ... 63/64) | |
| Description of the output | each 2 NO in series, safety-oriented, potential-free |
| Number of outputs | 5 |
| Contact Switching Type | 5 Release Intensity Circuits |
| Contact Material | AgSnO2 |
| Switching voltage | min. 10 V |
| max. 250 V AC/DC | |
| Min. switching power | min. 100 mW |
| Input current | min. 10 mA |
| max. 20 A (≤ 100 ms) | |
| Breaking capacity according to IEC 60947-5-1 | 3 A (AC15) |
| 5 A (DC13) | |
| Constant Current Limit | 6 A (observe derating) |
| Square. Current Sum | 72 A2(observe derating) |
| Switching frequency | max. 1 Hz |
| Mechanical service life | 10x 106operations |
| Output fuse | 10 A gL/gG |
| 4 A gL/gG (for low-demand applications) | |
| Relay: Signalling circuit (71/72) | |
| Description of the output | 2 NC in parallel, without safety orientation, floating |
| Number of outputs | 1 |
| Contact Switching Type | 1 x Signal Circuit |
| Contact Material | AgSnO2 |
| Switching voltage | min. 5 V AC/DC |
| max. 250 V AC/DC | |
| Min. switching power | min. 50 mW |
| Input current | min. 10 mA |
| max. 6 A | |
| Breaking capacity according to IEC 60947-5-1 | 1.5 A (AC15) |
| 5 A (DC13) | |
| Constant Current Limit | 6 A |
| Square. Current Sum | 36 A2 |
| Switching frequency | max. 1 Hz |
| Mechanical service life | 10x 106operations |
| Output fuse | 6 A (gL/gG) |
| Relay: Acknowledgment Circuit (11/12) | |
| Description of the output | Diagnostic contact, 2 NC in series, floating |
| Number of outputs | 1 |
| Contact Switching Type | 1 acknowledgment circuit |
| Contact Material | AgSnO2 |
| Switching voltage | max. 250 V AC/DC |
| min. 10 V | |
| Min. switching power | min. 100 mW |
| Input current | max. 6 A |
| Breaking capacity according to IEC 60947-5-1 | 1.5 A (AC15) |
| 3 A (DC13) | |
| Constant Current Limit | 6 A |
| Square. Current Sum | 36 A2 |
| Switching frequency | max. 0.5 Hz |
| Output fuse | 10 A (gL/gG) |
| Connection technology | |
| Plug | Yes |
| Connecting Conductors | |
| Connection type | Push-in connection |
| Rigid conductor section | 0.2 mm² ... 1.5 mm² |
| Flexible conductor section | 0.2 mm² ... 1.5 mm² |
| AWG Wire Section | 24 ... 16 |
| Length to be de-insulated | 8 mm |
| Operating voltage display | 1 x Green LED |
| Width | 22.5 mm |
| Height | 112 mm |
| Depth | 114.5 mm |
| Shell material | Polyamide |
| Technical Safety Data | |
| Stop Category | 0 |
| Technical safety data: EN ISO 13849 | |
| category | 4 (in combination with suitable evaluation device) |
| Performance Level (PL) | e (in combination with appropriate evaluation device) |
| Technical safety data: IEC 61508 - high demand | |
| Safety Integrity Level (SIL) | 3 (in combination with suitable evaluation device) |
| Technical safety data: IEC 61508 - low demand | |
| Safety Integrity Level (SIL) | 3 (in combination with suitable evaluation device) |
| Technical safety data: EN IEC 62061 | |
| Safety Integrity Level (SIL) | 3 (in combination with suitable evaluation device) |
| Environmental conditions | |
| Protection Index | IP20 |
| Minimum degree of protection of the installation site | IP54 |
| Ambient Temperature (Service) | -20 °C ... 55 °C (observe derating) |
| Ambient Temperature (Storage/Transport) | -40 °C ... 70 °C |
| Fixing height | max. 2000 m (via NN) |
| Max. permissible air humidity (storage/transport) | 75 % |
| Max. permissible air humidity (service) | 75 % |
| Crash | 35% |
| Vibration (service) | 10 Hz ... 150 Hz, amplitude 0.15 mm, 2g |
| Ce | |
| Marked | CE Compliance |
| Type of mounting | Rail mounting |
| Installation instructions | see Derating curve |
| Position for mounting | Vertical or horizontal |
| Connection type | Push-in connection |