View larger
PSR-SPP- 24DC/URM4/5X1/2X2 1442026 PHOENIX CONTACT Extension of 1 or 2 channel contacts, 5 normally open con..
PSR-SPP-24DC/URM4/5X1/2X2
1442026
PHOENIX CONTACT
1 Pcs.
Automation > Device for monitoring of safety-related circuits
Safety
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Safety relays such as the Phoenix Contact PSR-SPP-24DC/URM4/5X1/2X2 (part number 1442026) provide reliable signal processing and contact expansion for critical machine safety systems. These electromechanical components handle force-guided switching to protect operators and equipment during emergency stops. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: Safety relays
- Product family: PSRclassic
- Application: Extension module
- Mechanical service life: approx. 10 7 cycles
- Relay type: Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
- Times Typ. starting time with U s: < 25 ms (at Us / when controlled via A11/A12)
- Typical release time: < 20 ms (at Us / when controlled via A11/A12)
- Recovery time: < 1 s
- Maximum power dissipation for nominal condition: 16.7 W (U S = 26.4 V, I L ² = 72 A², P Total max = 1.4 W + 14.4 W)
- Nominal operating mode: 100% operating factor
- Rated surge voltage/insulation: See section “Insulation coordination”
- General Maximum switching frequency: 1 Hz
- Digital: A11, A12 Description of the input: safety-related
- Number of inputs: 2
- Input voltage range "1" signal: 19.2 V ... 26.4 V DC
- Max. permissible overall conductor resistance: 50 Ω
More info
▲| Product type | Safety relays |
| Product family | PSRclassic |
| Application | Extension module |
| Mechanical service life | approx. 107cycles |
| Relay type | Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3 |
| Times | |
| Typ. starting time with Us | < 25 ms (at Us / when controlled via A11/A12) |
| Typical release time | < 20 ms (at Us / when controlled via A11/A12) |
| Recovery time | < 1 s |
| Maximum power dissipation for nominal condition | 16.7 W (US= 26.4 V, IL² = 72 A², PTotal max= 1.4 W + 14.4 W) |
| Nominal operating mode | 100% operating factor |
| Air clearances and creepage distances between the power circuits | |
| Rated insulation voltage | 250 V |
| 250 V | |
| Rated surge voltage/insulation | See section “Insulation coordination” |
| General | |
| Maximum switching frequency | 1 Hz |
| Digital: A11, A12 | |
| Description of the input | safety-related |
| Number of inputs | 2 |
| Input voltage range "1" signal | 19.2 V ... 26.4 V DC |
| Max. permissible overall conductor resistance | 50 Ω |
| Protective circuit | Suppressor diode |
| Current consumption | typ. 39 mA |
| Relay: Enabling current paths (23/24 ... 63/64) | |
| Output description | 2 N/O contacts each in series, safety-related, floating |
| Number of outputs | 5 |
| Contact switching type | 5 enabling current paths |
| Contact material | AgSnO2 |
| Switching voltage | min. 10 V |
| max. 250 V AC | |
| Switching capacity | min. 100 mW |
| Inrush current | min. 10 mA |
| max. 6 A | |
| Switching capacity in accordance with IEC 60947-5-1 | 3 A (AC15) |
| 5 A (DC13) | |
| Limiting continuous current | 6 A (observe derating) |
| Sq. Total current | 72 A2(observe derating) |
| Switching frequency | max. 1 Hz |
| Mechanical service life | 10x 106cycles |
| Output fuse | 10 A gL/gG |
| 4 A gL/gG (for low-demand applications) | |
| Relay: Signaling current path (71/72) | |
| Output description | 2 N/C contacts parallel, non-safety-related, floating |
| Number of outputs | 1 |
| Contact switching type | 1 signaling current path |
| Contact material | AgSnO2 |
| Switching voltage | min. 5 V AC/DC |
| max. 250 V AC/DC | |
| Switching capacity | min. 50 mW |
| Inrush current | min. 10 mA |
| max. 6 A | |
| Switching capacity in accordance with IEC 60947-5-1 | 1.5 A (AC15) |
| 5 A (DC13) | |
| Limiting continuous current | 6 A |
| Sq. Total current | 36 A2 |
| Switching frequency | max. 1 Hz |
| Mechanical service life | 10x 106cycles |
| Output fuse | 6 A (gL/gG) |
| Relay: Confirmation current path (11/12) | |
| Output description | 2 N/C contacts in series, floating |
| Number of outputs | 1 |
| Contact switching type | 1 confirmation current path |
| Contact material | AgSnO2 |
| Switching voltage | max. 250 V AC/DC |
| min. 10 V | |
| Switching capacity | min. 100 mW |
| Inrush current | max. 3 A |
| Switching capacity in accordance with IEC 60947-5-1 | 1.5 A (AC15) |
| 3 A (DC13) | |
| Limiting continuous current | 3 A |
| Sq. Total current | 9 A2 |
| Switching frequency | max. 1 Hz |
| Output fuse | 3 A (gL/gG) |
| Connection technology | |
| pluggable | yes |
| Conductor connection | |
| Connection method | Push-in connection |
| Conductor cross section rigid | 0.2 mm² ... 1.5 mm² |
| Conductor cross section flexible | 0.2 mm² ... 1.5 mm² |
| Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6) |
| Conductor cross section flexible, with ferrule without plastic sleeve | 0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6) |
| Conductor cross-section AWG | 24 ... 16 |
| Stripping length | 8 mm |
| Operating voltage display | 2 x green LED |
| Width | 35 mm |
| Height | 112 mm |
| Depth | 114.5 mm |
| Housing material | Polyamide |
| Safety data | |
| Stop category | 0 |
| Safety data: EN ISO 13849 | |
| Category | 4 (In conjunction with suitable evaluating device) |
| Performance level (PL) | e (In conjunction with suitable evaluating device) |
| Safety data: IEC 61508 - High demand | |
| Safety Integrity Level (SIL) | 3 (In conjunction with suitable evaluating device) |
| Safety data: IEC 61508 - Low demand | |
| Safety Integrity Level (SIL) | 3 (In conjunction with suitable evaluating device) |
| Safety data: EN IEC 62061 | |
| Safety Integrity Level (SIL) | 3 (In conjunction with suitable evaluating device) |
| Ambient conditions | |
| Degree of protection | IP20 |
| Min. degree of protection of inst. location | IP54 |
| Ambient temperature (operation) | -20 °C ... 55 °C (observe derating) |
| Ambient temperature (storage/transport) | -40 °C ... 70 °C |
| Maximum altitude | ≤ 2000 m (Above sea level) |
| Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
| Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
| Shock | 15g |
| Vibration (operation) | 10 Hz ... 150 Hz, amplitude 0.15 mm, 2g |
| CE | |
| Identification | CE-compliant |
| Air clearances and creepage distances between the power circuits | |
| Standards/regulations | EN 60947-1 |
| Mounting type | DIN rail mounting |
| Assembly instructions | Observe derating |
| Mounting position | vertical or horizontal |
| Connection method | Push-in connection |