View larger
PSR-SPP- 24DC/MMS/1X1/THY 2981693 PHOENIX CONTACT Detector of escalators from two channels up to SIL3 (accor..
PSR-SPP-24DC/MMS/1X1/THY
2981693
PHOENIX CONTACT
1 Pcs.
Automation > Device for monitoring of safety-related circuits
Safety
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact PSR-SPP- 24DC/MMS/1X1/THY 2981693 PHOENIX CONTACT Detector of escalators from two channels up to SIL3 (accor.. serves as a specialized monitoring device engineered to oversee the operational safety of personnel transportation systems and heavy machinery. These controllers evaluate dual-channel sensor inputs to detect unintended motion and trigger immediate stops when safety thresholds are breached. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Model (EF000010): Basic device
- Suitable for rail mounting (EF003972): Yes
- With detachable clamps (EF003340): Yes
- Type of electric connection (EF003961): Spring clamp connection
- Suitable for monitoring of valves (EF007272): No
- Suitable for monitoring of tactile sensors (EF007271): No
- Suitable for monitoring of magnetic switches (EF007266): No
- Suitable for monitoring of proximity switches (EF007267): No
- With start input (EF003342): No
- With muting function (EF004057): No
- With feedback circuit (EF003343): No
- With approval for BG BIA (EF004145): No
- With approval according to UL (EF001783): Yes
- Width (EF000008): 22.5 mm
- Height (EF000040): 112 mm
- Depth (EF000049): 114.5 mm
More info
▲Data commercial
| Key order | Two million nine hundred eighty one thousand six hundred ninety three |
|---|---|
| Packing unit | 1 pcs |
| Key selling | DNA24X - |
| EAN | Four trillion forty six billion three hundred fifty six million ninety one thousand seven hundred forty nine |
| Unit weight (excluding packaging) | 176,800 g |
| Tariff number tariff | Ninety million three hundred twenty eight thousand nine hundred |
| Country of origin | DE (Germany) |
Observation
| Restriction of use | EMC: class A product, see manufacturer's declaration in the download center |
|---|
Environmental conditions
| Room temperature (service) | -10 °C ... 60 °C |
|---|---|
| Ambient temperature (storage / transport) | -40 °C ... 70 °C |
| Height of fixing | max. 2000 m (via NN) |
Data entry
| Supply voltage rated control circuit OrS | |
|---|---|
| Rated voltage input OrN | 24 V DC (PELV) |
| Input voltage range referred to OrN | 0,85 ... 1,1 |
| Input current typical with UN | 70 mA DC |
| Indication of the operating voltage | Green LED |
| Circuit protection | Prot. surge suppressor Diode |
| Limitation of voltage ≥ 33 V PTC Resistance | |
| Frequency limit | 1 kHz |
Output data
| Type of contact | 1 firing circuit |
|---|---|
| Contact Material | AgNi, + 5 µm Au |
| Switching voltage maximum | 250 V AC/DC |
| Minimum voltage of activation | 0.1 V AC/DC |
| Constant current limit | 2 A (open contact) |
| Current maximum connection | 2 A (open contact) |
| Current minimum closing | 1 mA |
| Breaking capacity (resistive load) maximum | 48 W (24 V DC, t = 0 ms) |
| 75 W (48 V DC, t = 0 ms) | |
| 55 W (110 V DC, t = 0 ms) | |
| 65 W (220 V DC, t = 0 ms) | |
| 500 VA (250 V AC, τ = 0 ms) | |
| Breaking capacity minimum | 60 mW |
| Mechanical life | 1x 10Sevenoperations |
| Output fuse | 6 To gL |
Overview
| Type of relay | Electromechanical relay with contacts driving enforced according to en 50205 |
|---|---|
| Type of operation nominal | Working time 100 % |
| Net weight | 176,8 g |
| Position to the mounting | discretionary |
| Mounting type | Mounting on a rail |
| Index of protection | IP20 |
| IP54 | |
| Degree of protection minimum of the place of assembly | IP54 |
| Color housing | yellow |
Data connection
| Type of connection | Connection by spring |
|---|---|
| plug-in | yes |
| Core cross-section rigid min. | 0,2 mm2 |
| Section of conductor rigid max. | 1.5 mm2 |
| Section of flexible conductor, min. | 0,2 mm2 |
| Section of flexible conductor max. | 1.5 mm2 |
| Section of conductor AWG min. | Twenty four |
| Section of conductor AWG max. | Sixteen |
| Length desaislar | 8 mm |
Technical parameters of safety
| Stop category | Zero |
|---|---|
| Name | IEC 61508 - high demand |
| Safety Integrity Level (SIL) | Two |
| Name | EN ISO 13849 |
| Performance Level (PL) | d |
| Category | Three |
| Name | En 62061 |
| Safety Integrity Level Claim Limit (SIL CL) | Two |
Standards and specifications
| Name | Lines of flight and air spaces between the circuits |
|---|---|
| Standards/specifications | DIN EN 50178/VDE 0160 |
| Isolation voltage design | 250 V |
| Transient voltage design / insulation | 4 kV / basic insulation |
| Pollution degree | Two |
| Category surge | II |
Environmental Product Compliance
| China RoHS | Space of time for the intended use: unlimited = FEUP-e |
|---|---|
| No dangerous substances above the thresholds |