View larger
PSR-SCP- 24DC/URM4/5X1/2X2/B 1442344 PHOENIX CONTACT Contact expansion 1 or 2 channels, 5 NO contacts, 1 NC ..
PSR-SCP-24DC/URM4/5X1/2X2/B
1442344
PHOENIX CONTACT
1 Pcs.
Automation > Device for monitoring of safety-related circuits
Safety
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Contact expansion safety relay identified as the Phoenix Contact PSR-SCP- 24DC/URM4/5X1/2X2/B, built to provide additional safe switching paths for high-current industrial actuators. Such modules operate downstream of safety control units, amplifying the switching capacity to handle heavier loads while preserving fault-tolerant monitoring integrity.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product Type: Safety Relays
- Product Family: PSRclassic
- Application: Expansion module
- Mechanical life: 10x 10 6 Manoeuvring cycles
- Relay Type: Electromagnetic relay with forcibly guided contacts according to IEC/EN 61810-3
- Times Tip. Excitation time with U s: < 25 ms (Us/command via A1)
- Typical Drop-Out Time: < 20 ms (Us/command via A1)
- Reset Time: < 1 s
- Maximum power dissipation under nominal conditions: 16.6 W (U S = 26.4 V, I L ² = 72 A², P Total max = 2.2 W + 14.4 W)
- Duty cycle report: 100 % ED
- Impulse voltage sizing/isolation: See chapter Insulation coordination
- Digital: A1 Entrance description: Security-oriented
- Number of inputs: 1
- Signal input range "1": 19.2 V ... 26.4 V
- Max. permissible cable resistance: 25 Ω
- Protection Circuit: Diode Suppressor
More info
▲| Product Type | Safety Relays |
| Product Family | PSRclassic |
| Application | Expansion module |
| Mechanical life | 10x 106Manoeuvring cycles |
| Relay Type | Electromagnetic relay with forcibly guided contacts according to IEC/EN 61810-3 |
| Times | |
| Tip. Excitation time with Us | < 25 ms (Us/command via A1) |
| Typical Drop-Out Time | < 20 ms (Us/command via A1) |
| Reset Time | < 1 s |
| Maximum power dissipation under nominal conditions | 16.6 W (US= 26.4 V, IL² = 72 A², PTotal max= 2.2 W + 14.4 W) |
| Duty cycle report | 100 % ED |
| Air and surface distances between circuits | |
| Rated insulation voltage | 250 V |
| Impulse voltage sizing/isolation | See chapter Insulation coordination |
| Digital: A1 | |
| Entrance description | Security-oriented |
| Number of inputs | 1 |
| Signal input range "1" | 19.2 V ... 26.4 V |
| Max. permissible cable resistance | 25 Ω |
| Protection Circuit | Diode Suppressor |
| Current consumption | tip. 75 mA |
| Relay: Safety Contacts (23/24 ... 63/64) | |
| Output Description | each 2 NO in series, safe, potential-free |
| Number of outputs | 5 |
| Contact Switching Type | 5 safety contacts |
| Contact material | AgSnO2 |
| Switchable voltage | Min. 10 V |
| max. 250 V AC/DC | |
| Switchable power | Min. 100 mW |
| Instantaneous current | Min. 10 mA |
| max. 20 A (≤ 100 ms) | |
| Breaking capacity IEC 60947-5-1 | 3 A (AC15) |
| 5 A (DC13) | |
| Permanent Load Current | 6 A (take into account derating) |
| arit. Total current | 72 A2(take into account derating) |
| Switching frequency | max. 1 Hz |
| Mechanical life | 10x 106Manoeuvring cycles |
| Output fuse | 10 A gL/gG |
| 4 A gL/gG (for Low Demand applications) | |
| Relay: Signal contact (71/72) | |
| Output Description | 2 parallel, non-safety-oriented, potential-free NCs |
| Number of outputs | 1 |
| Contact Switching Type | 1 signal output contact |
| Contact material | AgSnO2 |
| Switchable voltage | Min. 5 V AC/DC |
| max. 250 V AC/DC | |
| Switchable power | Min. 50 mW |
| Instantaneous current | Min. 10 mA |
| max. 6 A | |
| Breaking capacity IEC 60947-5-1 | 1.5 A (AC15) |
| 5 A (DC13) | |
| Permanent Load Current | 6 A |
| arit. Total current | 36 A2 |
| Switching frequency | max. 1 Hz |
| Mechanical life | 10x 106Manoeuvring cycles |
| Output fuse | 6 A (gL/gG) |
| Relay: Feedback Loop (11/12) | |
| Output Description | Diagnostic Contact, 2 NC in Series, Potential Free |
| Number of outputs | 1 |
| Contact Switching Type | 1 feedback loop |
| Contact material | AgSnO2 |
| Switchable voltage | max. 250 V AC/DC |
| Min. 10 V | |
| Switchable power | Min. 100 mW |
| Instantaneous current | max. 6 A |
| Breaking capacity IEC 60947-5-1 | 1.5 A (AC15) |
| 3 A (DC13) | |
| Permanent Load Current | 6 A |
| arit. Total current | 36 A2 |
| Switching frequency | max. 0.5 Hz |
| Output fuse | 10 A (gL/gG) |
| Connection technology | |
| plug-in | Yes |
| Conductor connection | |
| Link | Screw connection |
| Rigid conductor cross-section | 0.2 mm² ... 2.5 mm² |
| Flexible conductor cross-section | 0.2 mm² ... 2.5 mm² |
| AWG conductor cross-section | 24 ... 12 |
| Stripping length | 7 mm |
| Thread | M3 |
| Tightening torque | 0.5 Nm ... 0.6 Nm |
| Operating voltage indication | 1 x Green LEDs |
| width | 22.5 mm |
| height | 99 mm |
| Depth | 114.5 mm |
| Housing Material | Polyamide |
| Technical safety data | |
| Stop category | 0 |
| Technical safety data: EN ISO 13849 | |
| Category | 4 (in combination with a suitable measuring device) |
| Performance Level (PL) | and (in combination with a suitable measuring device) |
| Technical safety data: IEC 61508 - High-Demand | |
| Safety Integrity Level (SIL) | 3 (in combination with a suitable measuring device) |
| Technical safety data: IEC 61508 - Low-Demand | |
| Safety Integrity Level (SIL) | 3 (in combination with a suitable measuring device) |
| Technical safety data: EN IEC 62061 | |
| Safety Integrity Level (SIL) | 3 (in combination with a suitable measuring device) |
| Environmental conditions | |
| Degree of protection | Ip20 |
| Degree of protection Installation location min. | IP54 |
| Ambient temperature (operating) | -20 °C ... 55 °C (take into account derating) |
| Ambient temperature (storage/transport) | -40 °C ... 70 °C |
| height | max. 2000 m (on NN) |
| Max. humidity. Permitted (storage/transport) | 75 % |
| Maximum permissible humidity (operation) | 75 % |
| Shock | 15g |
| Vibration (operation) | 10 Hz ... 150 Hz, 0.15 mm amplitude, 2g |
| Ec | |
| Marking | CE Compliance |
| Air and surface distances between circuits | |
| Standards/Provisions | EN 60947-1 |
| Mounting type | Rail Mounting |
| Installation instructions | See Derating curve |
| Installation Location | Vertical or horizontal |
| Link | Screw connection |