View larger
PSR-SCP-24DC/ESD/4X1/30-SET35 1217839 PHOENIX CONTACT Set of 35 pieces of safety relays for the supervision ..
PSR-SCP-24DC/ESD/4X1/30-SET35
1217839
PHOENIX CONTACT
1 Pcs.
Automation > Device for monitoring of safety-related circuits
Safety
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact PSR-SCP-24DC/ESD/4X1/30-SET35 is a set of safety relays used for emergency stop supervision and general machine protection. These devices verify the integrity of safety circuits to prevent accidental startup and ensure rapid shutdown during hazardous events. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: Safety relays
- Product family: PSRclassic
- Application: Emergency stop
- Mechanical service life: approx. 10 7 cycles
- Relay type: Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
- Maximum power dissipation for nominal condition: 1.8 W
- Nominal operating mode: 100% operating factor
- Rated surge voltage/insulation: 4 kV / basic insulation
- General Nominal input voltage U N: 24 V DC
- Input voltage range in reference to U N: 0.85 ... 1.1
- Typical input current at U N: 75 mA DC
- Voltage at input/start and feedback circuit: approx. 24 V DC
- Typical response time: 150 ms (Monitored/manual and auto-start)
- Typical release time: 20 ms (Undelayed contacts)
- Typical release time range: 0.1 s ... 30 s
- Recovery time: 330 ms (Restart)
More info
▲| Product type | Safety relays |
| Product family | PSRclassic |
| Application | Emergency stop |
| Safety door | |
| Light grid | |
| Mechanical service life | approx. 107cycles |
| Relay type | Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3 |
| Maximum power dissipation for nominal condition | 1.8 W |
| Nominal operating mode | 100% operating factor |
| Air clearances and creepage distances between the power circuits | |
| Rated insulation voltage | 250 V |
| Rated surge voltage/insulation | 4 kV / basic insulation |
| General | |
| Nominal input voltage UN | 24 V DC |
| Input voltage range in reference to UN | 0.85 ... 1.1 |
| Typical input current at UN | 75 mA DC |
| Voltage at input/start and feedback circuit | approx. 24 V DC |
| Typical response time | 150 ms (Monitored/manual and auto-start) |
| Typical release time | 20 ms (Undelayed contacts) |
| 100 ms (delayed contacts) | |
| Typical release time range | 0.1 s ... 30 s |
| Recovery time | 330 ms (Restart) |
| 1 s (Electric torque) | |
| Protective circuit | Suppressor diode, 33 V DC |
| Max. permissible overall conductor resistance | 500 Ω (Input and reset circuit at UN) |
| Operating voltage display | Green LED |
| Status display | LED K1/K2 and K3(t)/K4(t), green |
| Contact switching type | 4 enabling current paths |
| Contact material | AgSnO2 |
| Maximum switching voltage | 250 V AC/DC |
| Minimum switching voltage | 15 V AC/DC |
| Limiting continuous current | 6 A (N/O contact) |
| Maximum inrush current | 6 A |
| Inrush current, minimum | 25 mA |
| Sq. Total current | 120 A2(see to derating) |
| Interrupting rating (ohmic load) max. | 144 W (24 V DC, τ = 0 ms) |
| 288 W (48 V DC, τ = 0 ms) | |
| 90 W (110 V DC, τ = 0 ms) | |
| 88 W (220 V DC, τ = 0 ms) | |
| 1500 VA (250 V AC, τ = 0 ms) | |
| Maximum interrupting rating (inductive load) | 42 W (24 V DC, τ = 40 ms) |
| 33 W (48 V DC, τ = 40 ms) | |
| 25 W (110 V DC, τ = 40 ms) | |
| 23 W (220 V DC, τ = 40 ms) | |
| Switching capacity min. | 0.4 W |
| Switching capacity (360/h cycles) | on request |
| Switching capacity (3600/h cycles) | 3 A (24 V (DC13)) |
| 3 A (230 V (AC15)) | |
| Output fuse | 10 A gL/gG NEOZED (N/O contact) |
| Connection technology | |
| pluggable | yes |
| Conductor connection | |
| Connection method | Screw connection |
| Conductor cross section, rigid | 0.2 mm² ... 2.5 mm² |
| Conductor cross section, flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross section AWG | 24 ... 12 |
| Stripping length | 7 mm |
| Screw thread | M3 |
| Width | 22.5 mm |
| Height | 99 mm |
| Depth | 114.5 mm |
| Housing material | Polyamide |
| Safety data | |
| Stop category | 0 |
| 1 | |
| Safety data: EN ISO 13849 | |
| Category | 4 |
| Performance level (PL) | e |
| Safety data | |
| Safety Integrity Level (SIL) | 3 |
| Safety data | |
| Safety Integrity Level (SIL) | 3 |
| Ambient conditions | |
| Degree of protection | IP20 |
| Min. degree of protection of inst. location | IP54 |
| Ambient temperature (operation) | -20 °C ... 45 °C |
| Ambient temperature (storage/transport) | -40 °C ... 70 °C |
| Maximum altitude | ≤ 2000 m (Above sea level) |
| Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
| Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
| Shock | 15g |
| Vibration (operation) | 10 Hz ... 150 Hz, 2g |
| Air clearances and creepage distances between the power circuits | |
| Standards/regulations | DIN EN 60947-1 |
| Mounting type | DIN rail mounting |
| Mounting position | any |
| Connection method | Screw connection |