View larger
PSR-PLC21-2CO-24DC-PT 1480212 PHOENIX CONTACT Safe coupling relay with forced guide contacts, with galvanic ..
PSR-PLC21-2CO-24DC-PT
1480212
PHOENIX CONTACT
10 Pcs.
Automation > Switching relay
Safety
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Providing critical functional safety management, this PSR-PLC21-2CO-24DC-PT 1480212 PHOENIX CONTACT Safe coupling relay with forced guide contacts, with galvanic acts as an electromechanical interlock device designed to monitor safety circuits, prevent contact welding hazards, and ensure reliable fault detection in emergency stop loops. It is commonly integrated into machine safety architectures and industrial automation lines to protect both operators and equipment.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: Coupling relay
- Product family: PLC-INTERFACE
- Application: Forcibly guided contacts
- Mechanical service life: approx. 10 7 cycles
- Relay type: Electromechanical relay in accordance with IEC/EN 61810
- Pollution degree: 2
- Times Typ. starting time with U s: < 70 ms (when controlled via A1)
- Typical release time: < 50 ms (on demand via A1)
- Recovery time: 500 ms (following demand of the safety function)
- Maximum power dissipation for nominal condition: 4.825 W (U B = 30 V, U S = 24 V, I S = 30 mA, I L ² = 37 A, R contact = 0.1 Ω)
- Nominal operating mode: 100% operating factor
- Rated surge voltage/insulation: Basic insulation 4 kV between all current paths and housing
- Supply Designation: A1/A2
- Rated control circuit supply voltage U S: 21.6 V DC ... 28.8 V DC
- Rated control circuit supply voltage U S: 24 V DC -10 % / +20 %
- Rated control supply current I S: 30 mA
More info
▲| Product type | Coupling relay |
| Product family | PLC-INTERFACE |
| Application | Forcibly guided contacts |
| Mechanical service life | approx. 107cycles |
| Relay type | Electromechanical relay in accordance with IEC/EN 61810 |
| Insulation characteristics: Air clearances and creepage distances between the power circuits | |
| Overvoltage category | III |
| Pollution degree | 2 |
| Times | |
| Typ. starting time with Us | < 70 ms (when controlled via A1) |
| Typical release time | < 50 ms (on demand via A1) |
| Recovery time | 500 ms (following demand of the safety function) |
| Maximum power dissipation for nominal condition | 4.825 W (UB= 30 V, US= 24 V, IS= 30 mA, IL² = 37 A, Rcontact= 0.1 Ω) |
| Nominal operating mode | 100% operating factor |
| Air clearances and creepage distances between the power circuits | |
| Rated insulation voltage | 250 V AC |
| Rated surge voltage/insulation | Basic insulation 4 kV between all current paths and housing |
| Safe isolation, reinforced insulation 6 kV between 250 V load current paths and 24 V logic paths | |
| Supply | |
| Designation | A1/A2 |
| Rated control circuit supply voltage US | 21.6 V DC ... 28.8 V DC |
| Rated control circuit supply voltage US | 24 V DC -10 % / +20 % |
| Rated control supply current IS | 30 mA |
| Inrush current | typ. 100 mA (Δt = 10 ms at Us) |
| Filter time | 1 ms (Test pulse width, high test pulse and low test pulse) |
| 1 s (Test pulse rate, high test pulse and low test pulse) | |
| Power consumption at UD | 650 mW (to US) |
| Protective circuit | Serial protection against polarity reversal; Suppressor diode, 38.6 V/600 W |
| Status display | 1 x green LED (PWR) |
| Relay: Relay outputs (11/12/14, 21/22/24) | |
| Output description | safety-related |
| Number of outputs | 2 |
| Contact switching type | 2 changeover contacts |
| Contact material | AgNi |
| Switching capacity | min. 150 mW (N/O contact / N/C contact) |
| Inrush current | max. 6 A (N/O contact) |
| max. 4 A (N/C contact) | |
| Switching capacity in accordance with IEC 60947-5-1 | 6 A (AC1, 230 V) |
| 3 A (AC15, 230 V) | |
| 6 A (DC1, 24 V, N/O contact) | |
| 4 A (DC1, 24 V, N/C contact) | |
| 3 A (DC13, 24 V, N/O contact) | |
| Limiting continuous current | 6 A (N/O contact, high demand) |
| 4 A (N/O contact, low demand) | |
| 4 A (N/C contact, high-demand) | |
| 2.4 A (N/C contact, low-demand) | |
| Sq. Total current | 37 A2(N/O contact, high-demand, observe derating) |
| 16 A2(N/C contact, high-demand, observe derating) | |
| Switching frequency | max. 1 Hz |
| Mechanical service life | 107cycles |
| Output fuse | 6 A gL/gG |
| 4 A gL/gG (for low-demand applications) | |
| Conductor connection | |
| Connection method | Push-in connection |
| Conductor cross section rigid | 0.14 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve | 0.2 mm² ... 2.5 mm² |
| Conductor cross-section AWG | 26 ... 14 |
| Stripping length | 8 mm |
| Operating voltage display | 1 x green LED (PWR) |
| Width | 14 mm |
| Height | 80 mm |
| Depth | 104 mm |
| Housing material | Polyamide |
| Safety data: EN ISO 13849 | |
| Category | 1 |
| Performance level (PL) | c |
| Safety data: IEC 61508 – High-demand for 1-channel wiring (1oo1 structure) | |
| Safety Integrity Level (SIL) | 2 |
| Safety data: IEC 61508 – Low-demand for 1-channel wiring (1oo1 structure) | |
| Safety Integrity Level (SIL) | 2 |
| Safety data: EN IEC 62061 | |
| Safety Integrity Level (SIL) | 2 |
| Ambient conditions | |
| Degree of protection | IP20 |
| Min. degree of protection of inst. location | IP54 |
| Ambient temperature (operation) | -20 °C ... 60 °C (observe derating) |
| Ambient temperature (storage/transport) | -20 °C ... 85 °C |
| Maximum altitude | ≤ 2000 m (Above sea level) |
| Max. permissible humidity (storage/transport) | 75 % (on average; 95% occasionally, non-condensing) |
| Max. permissible relative humidity (operation) | 75 % (on average; 95% occasionally, non-condensing) |
| Shock | 10g for Δt = 11 ms (continuous shock: 5g for Δt = 16 ms) |
| Vibration (operation) | 10 Hz ... 150 Hz, amplitude 0.75 mm, 1g |
| CE | |
| Identification | CE-compliant |
| Air clearances and creepage distances between the power circuits | |
| Standards/regulations | IEC 60947-1 |
| Mounting type | DIN rail mounting |
| Assembly instructions | See derating curve |
| Mounting position | vertical or horizontal |
| Connection method | Push-in connection |