View larger
PSR-PE20-1NO-24DC-SC-SET60 1272930 PHOENIX CONTACT Set of 60 coupling relays for low demand SIL 3 applicatio..
PSR-PE20-1NO-24DC-SC-SET60
1272930
PHOENIX CONTACT
1 Pcs.
Automation > Device for monitoring of safety-related circuits
Safety
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
This bulk set of coupling relays, designated as the Phoenix Contact PSR-PE20-1NO-24DC-SC-SET60 1272930 PHOENIX CONTACT Set of 60 coupling relays for low demand SIL 3 applicatio.., is designed for safe electrical signal isolation and low-demand functional safety applications. Electromechanical components of this standard ensure dependable circuit switching across industrial automation infrastructure. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: Coupling relay
- Product family: PSRclassic
- Application: Safe switch off
- Mechanical service life: 10x 10 6 cycles
- Relay type: Electromechanical relay in accordance with IEC/EN 61810
- Times Typ. starting time with U s: < 70 ms (when controlled via A3 at U S )
- Typical release time: < 50 ms (on demand via A3 at U S )
- Recovery time: 500 ms
- Maximum power dissipation for nominal condition: 2.36 W (U B = 26.4 V, U S = 24 V, I S = 40 mA, I L ² = 16 A, R contact = 0.075 Ω)
- Nominal operating mode: 100% operating factor
- Supply Designation: 3/4
- Rated control circuit supply voltage U S: 21.6 V DC ... 26.4 V DC
- Rated control circuit supply voltage U S: 24 V DC -10 % ... +10 %
- Rated control supply current I S: 40 mA
- Power consumption at U S: 960 mW
- Inrush current: typ. 100 mA (Δt = 10 ms at U s )
More info
▲| Product type | Coupling relay |
| Product family | PSRclassic |
| Application | Safe switch off |
| Low demand | |
| Mechanical service life | 10x 106cycles |
| Relay type | Electromechanical relay in accordance with IEC/EN 61810 |
| Times | |
| Typ. starting time with Us | < 70 ms (when controlled via A3 at US) |
| Typical release time | < 50 ms (on demand via A3 at Us) |
| Recovery time | 500 ms |
| Maximum power dissipation for nominal condition | 2.36 W (UB= 26.4 V, US= 24 V, IS= 40 mA, IL² = 16 A, Rcontact= 0.075 Ω) |
| Nominal operating mode | 100% operating factor |
| Air clearances and creepage distances between the power circuits | |
| Rated insulation voltage | 250 V AC |
| Rated surge voltage/insulation | Safe isolation, reinforced insulation 6.4 kV between 250 V load current paths and 24 V logic paths |
| Basic insulation 4 kV between all current paths and housing | |
| Supply | |
| Designation | 3/4 |
| Rated control circuit supply voltage US | 21.6 V DC ... 26.4 V DC |
| Rated control circuit supply voltage US | 24 V DC -10 % ... +10 % |
| Rated control supply current IS | 40 mA |
| Power consumption at US | 960 mW |
| Inrush current | typ. 100 mA (Δt = 10 ms at Us) |
| Filter time | 1 ms (in the event of voltage dips at Us) |
| Protective circuit | Serial protection against polarity reversal; Suppressor diode, 38.6 V/600 W (connections 3/4) |
| Relay: Enabling current path (5/6) | |
| Output description | 1 NO |
| Number of outputs | 1 (safety-related) |
| Contact switching type | 1 enabling current path |
| Contact material | AgSnO2, gold-plated |
| Switching voltage | min. 12 V DC |
| max. 250 V AC/DC (Observe the load curve) | |
| Switching capacity | min. 120 mW |
| Inrush current | min. 10 mA |
| max. 4 A | |
| Limiting continuous current | 4 A (Low demand) |
| Sq. Total current | 16 A2(Low-demand, observe derating) |
| Switching frequency | 1 Hz |
| Mechanical service life | 10x 106cycles |
| Output fuse | 4 A gL/gG (for low-demand applications) |
| Conductor connection | |
| Connection method | Screw connection |
| Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross-section AWG | 24 ... 12 |
| Stripping length | 7 mm |
| Screw thread | M3 |
| Tightening torque | 0.6 Nm |
| Status display | 1 x green LED |
| Width | 12.5 mm |
| Height | 99 mm |
| Depth | 114.5 mm |
| Housing material | Polyamide |
| Safety data: IEC 61508 - Low-demand for 1-channel wiring (1oo3 structure without diagnostics) | |
| Safety Integrity Level (SIL) | 3 |
| Ambient conditions | |
| Degree of protection | IP20 |
| Min. degree of protection of inst. location | IP54 |
| Ambient temperature (operation) | -40 °C ... 70 °C (observe derating) |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Maximum altitude | ≤ 2000 m (Above sea level) |
| Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
| Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
| Shock | 15g |
| Vibration (operation) | 10 Hz ... 150 Hz, 2g |
| CE | |
| Identification | CE-compliant |
| Air clearances and creepage distances between the power circuits | |
| Standards/regulations | EN 61010-1, EN 60947-1, EN 60079-15 |
| Mounting type | DIN rail mounting |
| Assembly instructions | See derating curve |
| Mounting position | vertical or horizontal |
| Connection method | Screw connection |