View larger
PSR-PC52-1NO-1NC-24DC-SP 1017064 PHOENIX CONTACT Coupling relay
PSR-PC52-1NO-1NC-24DC-SP
1017064
PHOENIX CONTACT
1 Pcs.
Automation > Device for monitoring of safety-related circuits
Safety
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A coupling relay such as the Phoenix Contact PSR-PC52-1NO-1NC-24DC-SP is utilized in control panels to electrically isolate low-voltage control signals from higher-power industrial loads or to safely multiply contact outputs. These devices ensure reliable signal transmission between automation controllers and field actuators while protecting sensitive electronics from power surges. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Model (EF000010): Basic device
- Suitable for rail mounting (EF003972): Yes
- With detachable clamps (EF003340): Yes
- Type of electric connection (EF003961): Spring clamp connection
- Suitable for monitoring of valves (EF007272): No
- Suitable for monitoring of tactile sensors (EF007271): No
- Suitable for monitoring of magnetic switches (EF007266): No
- Suitable for monitoring of proximity switches (EF007267): No
- With start input (EF003342): No
- With muting function (EF004057): No
- With feedback circuit (EF003343): No
- Release-delay (EF001129): 0.1 s
- With approval for BG BIA (EF004145): No
- With approval according to UL (EF001783): No
- Width (EF000008): 17.5 mm
- Height (EF000040): 117.4 mm
More info
▲Key Commercial Data
| Orderkey | 1017064 |
|---|---|
| Packing unit | 1 pc |
| GTIN | 4055626674032 |
| Weight per Piece (excluding packing) | 147.160 g |
| Custom tariff number | 85364190 |
| Country of origin | DE (Germany) |
Note
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 60 °C (observe derating) |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 65 °C |
| Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
| Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
| Air pressure (operation) | 79 kPa ... 106 kPa |
| Air pressure (storage/transport) | 79 kPa ... 106 kPa |
| Maximum altitude | ≤ 2000 m (Above sea level) |
Power supply
| Rated control circuit supply voltage US | 24 V DC -15 % / +10 % |
|---|---|
| 20.4 V DC ... 26.4 V DC | |
| Rated control supply current IS | typ. 75 mA |
| Power consumption at US | typ. 2 W (at US/UD; On state) |
| Inrush current | max. 100 mA |
| Filter time | 2 ms (at A1-A2 in the event of voltage dips at Us) |
| max. 2 ms (at A1-A2; low test pulse width) | |
| ≥ 100 ms (at A1-A2; low test pulse rate) | |
| max. 17 ms (at A1-A2; high test pulse width) | |
| ≥ 800 ms (at A1-A2; high test pulse rate) | |
| Diagnostic supply voltage UD | 24 V DC -20 % / +25 % |
| Input current at UD | 35 mA (at UD= 24 V) |
| 45 mA (at UD= 19 V) | |
| 25 mA (at UD= 30 V) | |
| Inrush current at UD | 1.5 A (Δt |
| Power consumption at UD | typ. 0.9 W (at UD; Off state) |
| Protective circuit | Surge protection 36 V suppressor diode (A1-A2)33 V suppressor diode (24V-GND) |
| Polarity reversal protection for rated control circuit supply voltage and diagnostic supply voltage |
Digital inputs
| Description of the input | Test point for proof test |
|---|---|
| Number of inputs | 3 |
| Inrush current | typ. 200 mA |
| Current consumption | typ. 20 mA (Input TP1) |
| typ. 20 mA (Input TP2) | |
| typ. 30 mA (Input TP3) | |
| Type of protection | Surge protection |
| Protective circuit/component | 36 V suppressor diode |
Relay outputs: enabling current path
| Output name | Enabling current path |
|---|---|
| Output description | safety-related N/O contacts |
| Number of outputs | 1 (undelayed) |
| Contact type | 1 enabling current path |
| Contact material | AgNi, gold-flashed, Ag alloy |
| Switching voltage | min. 16 V AC/DC |
| max. 250 V AC | |
| max. 125 V DC | |
| Limiting continuous current | 3 A (Observe derating, load type, and on-load voltage) |
| Inrush current | min. 50 mA |
| max. 5 A (Δt 1 s) | |
| Sq. Total current | 9 A2(observe derating) |
| Switching capacity | min. 1 W |
| Switching frequency | max. 0.5 Hz |
| Diagnostic threshold | 7 Ω ... 20 kΩ (configurable) |
| Mechanical service life | approx. 5x 107cycles |
Relay outputs: return current/signaling current path
| Output name | Signaling current path |
|---|---|
| Output description | non-safety-related N/C contact |
| Number of outputs | 1 (without delay, floating) |
| Contact type | 1 signaling current path |
| Inrush current | max. 800 mA (Δt 100 ms) |
| Short-circuit protection | no |
Times
| Typical pickup time at US | typ. 100 ms (when controlled via A1-A2) |
|---|---|
| Typical release time at US | typ. 30 ms (when controlled via A1-A2) |
| Recovery time | 1 s (when controlled via A1-A2) |
General
| Relay type | Electromechanical relay |
|---|---|
| Nominal operating mode | 100% operating factor |
| Net weight | 147.16 g |
| Mounting position | vertical or horizontal |
| Mounting type | DIN rail mounting |
| Assembly instructions | See derating curve |
| Degree of protection | IP20 |
| Min. degree of protection of inst. location | IP54 |
| Housing material | Frianyl A 63 R V0 |
| Housing color | yellow |
| Status display | 1 x yellow LED, 1 x green LED, 1 x red LED |
Connection data
| Connection method | Spring-cage connection |
|---|---|
| pluggable | Yes |
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 1.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 1.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 16 |
| Stripping length | 8 mm |
Safety-related characteristic data
| Designation | IEC 61508 - Low demand |
|---|---|
| Safety Integrity Level (SIL) | 3 |
| Designation | EN 50156-2 |
| Safety Integrity Level (SIL) | 3 (Reference IEC 61508) |
Standards and Regulations
| Designation | Air clearances and creepage distances between the power circuits |
|---|---|
| Standards/regulations | DIN EN 50178 |
| Rated insulation voltage | 250 V AC |
| Rated surge voltage/insulation | Basic insulation 4 kV between all current paths and housing |
| Safe isolation, 6 kV reinforced insulation from (A1/A2, 24V/0V, 21/22, and TP1/TP2/TP3) to the enabling current path (L, L', LO, LO', NI, NI', N,N') | |
| Degree of pollution | 2 |
| Overvoltage category | III |
| Shock | 15g, 11 ms |
| Vibration (operation) | 10 Hz ...150 Hz, 2g |
| Conformance | CE-compliant |
| Environmental simulation test | ISA-S71.04 (G3) |
Environmental Product Compliance
| China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
|---|---|
| No hazardous substances above threshold values |