Designed to provide robust protection in automated environments, the Phoenix Contact PSR-MM30-2NO-2DO-24DC-SP 2702358 two-channel zero-speed and over-speed safety relays up to S.. safeguards personnel and equipment through dependable safety monitoring. Safety relays are deployed in industrial systems to evaluate inputs from emergency stops and safety gates, guaranteeing that machinery powers down safely upon command. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated control supply voltage DC (EF003980): 24 V
- Voltage type for actuating (EF008242): DC
- With detachable clamps (EF003340): Yes
- Function rotational speed monitoring (EF003430): No
- Function standstill monitoring (EF003431): Yes
- Rated operating frequency (EF007370): 2000 Hz
- With feedback circuit (EF003343): No
- Suitable for safety functions (EF001597): Yes
- With approval for BG BIA (EF004145): No
- With approval according to UL (EF001783): Yes
- Width (EF000008): 22.5 mm
- Height (EF000040): 117.5 mm
- Depth (EF000049): 114.5 mm
More info
▲Key Commercial Data
| Orderkey | 2702358 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 243 (C-6-2019) |
| GTIN | 4055626133232 |
| Weight per Piece (excluding packing) | 0.000 g |
| Custom tariff number | 90328900 |
| Country of origin | DE (Germany) |
Note
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
Ambient conditions
| Ambient temperature (operation) | -40 °C ... 55 °C (observe derating) |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 70 °C |
| Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
| Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
| Maximum altitude | ≤ 2000 m (Above sea level) |
Power supply
| Designation | A1/A2 |
|---|---|
| Rated control circuit supply voltage US | 24 V DC -15 % / +10 % |
| Rated control supply current IS | typ. 74 mA |
| Power consumption at US | typ. 1.78 W |
| Inrush current | < 18 A (Δt = 500 µs at Us) |
| Filter time | 2 ms (at A1 in the event of voltage dips at Us) |
| Protective circuit | Serial protection against polarity reversal 33 V suppressor diode |
Digital inputs
| Input name | Operating mode and monitoring inputs |
|---|---|
| Description of the input | NPN, IEC 61131-2, type 1 |
| Number of inputs | 1 (Non-safety-related start input: S34) |
| 3 (Safety-related operating mode inputs: I1, I2, I3) | |
| 2 (Safety-related monitoring inputs: MI1, MI2) | |
| Input voltage range "0" signal | 0 V DC ... 5 V DC |
| Input voltage range "1" signal | 15 V DC ... 30 V DC |
| Input current range "0" signal | 0 mA ... 1.5 mA |
| Inrush current | < 5 mA |
| Current consumption | typ. 4 mA (at US) |
| Filter time | max. 2 ms (Test pulse width; low test pulses for operating mode and monitoring inputs) |
| Test pulse rate = 5 x Test pulse width | |
| Max. permissible overall conductor resistance | 150 Ω |
| Discrepancy time | 2 s (I1, I2, I3) |
| 2.5 s (MI1, MI2) | |
| Protective circuit/component | 33 V suppressor diode |
Measuring inputs
| Input name | Proximity switch inputs |
|---|---|
| Description of the input | NPN, IEC 61131-2, type 1 |
| Number of inputs | 2 (Safety-related proximity switch inputs: IN1 IN2) |
| Precision | ± 2 % (in reference to the parameterized limit value) |
| Inrush current | < 12 mA |
| Current consumption | typ. 10 mA (at US) |
| Input voltage range "0" signal | 0 V DC ... 5 V DC |
| Input voltage range "1" signal | 15 V DC ... 30 V DC |
| Input current range "0" signal | 0 mA ... 1.5 mA |
| Max. permissible overall conductor resistance | 150 Ω |
| Limit frequency | max. 2 kHz (Minimum pulse duration: 2 µs) |
| Protective circuit | 33 V suppressor diode |
| Input name | Encoder input |
| Description of the input | TTL, HTL, Sin/Cos |
| Number of inputs | 1 (Safety-related encoder input, RJ45) |
| Precision | ± 2 % (in reference to the parameterized limit value) |
| Current consumption | < 3 mA (Per track for US) |
| Max. permissible overall conductor resistance | 150 Ω |
| Limit frequency | max. 400 kHz |
| max. 250 kHz For active diagnostic safety encoder | |
| HTL signal form | 0 V DC ... 3 V DC (Low) |
| 12 V DC ... 30 V DC (High) | |
| TTL signal form | 0 V DC ... 0.9 V DC (Low) |
| 2.5 V DC ... 5 V DC (High) | |
| Sine/cosine signal form | 2 V DC ... 3 V DC (1 Vppdifferential signal) |
Relay outputs: enabling current path
| Output name | Enabling current path |
|---|---|
| Output description | 2 NO contacts each in series, without delay, floating |
| Number of outputs | 2 (safety-related N/O contacts: 13/14, 23/24) |
| Contact type | 2 enabling current paths |
| Contact material | AgSnO2 |
| Switching voltage | min. 12 V AC/DC |
| max. 250 V AC/DC (Observe the load curve) | |
| Limiting continuous current | 6 A |
| Inrush current | min. 3 mA |
| max. 6 A | |
| Sq. Total current | 72 A2(observe derating) |
| Switching capacity | min. 60 mW |
| Switching frequency | max. 0.5 Hz |
| Mechanical service life | 10x 106cycles |
| Switching capacity according to IEC 60947-5-1 | 4 A (24 V (DC13)) |
| 5 A (250 V (AC15)) | |
| Output fuse | 6 A gL/gG |
Alarm outputs
| Output description | PNP |
|---|---|
| Number of outputs | 2 (Non-safety-related signal outputs: MO1, MO2) |
| Voltage | approx. 22 V DC (Us- 2 V) |
| Current | max. 100 mA |
| Maximum inrush current | 500 mA (Δt = 1 ms at Us) |
| Protective circuit/component | 33 V suppressor diode |
| Short-circuit protection | no |
Times
| Typical response time at US | < 200 ms (For Usautostart) |
|---|---|
| < 150 ms (For Usmanual, monitored start) | |
| Delay time range | 0 s ... 10 s ±10 % (Adjustable switch-on delay for downtime contacts 23/24) |
| Restart time | < 1 s (Boot time) |
| Recovery time | < 1 s |
General
| Relay type | Electromechanical relay with forcibly guided contacts in accordance with IEC/EN 61810-3 (EN 50205) |
|---|---|
| Nominal operating mode | 100% operating factor |
| Net weight | 190.9 g |
| Mounting position | vertical or horizontal |
| Mounting type | DIN rail mounting |
| Assembly instructions | See derating curve |
| Degree of protection | IP20 |
| Min. degree of protection of inst. location | IP54 |
| Housing material | PBT |
| Housing color | yellow |
| Operating voltage display | 1 x green LED (PWR) |
| Status display | 2x LED green (OUT1, OUT2) |
Connection data
| Connection method | Push-in connection |
|---|---|
| pluggable | Yes |
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 1.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 1.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 16 |
| Stripping length | 8 mm |
Safety-related characteristic data
| Stop category | 0 |
|---|---|
| Designation | IEC 61508 - High demand |
| Safety Integrity Level (SIL) | 3 |
| Designation | EN ISO 13849 |
| Performance level (PL) | e (6 A DC1, 17520 switching cycles/year) |
| Category | 4 |
| Designation | EN 62061 |
| Safety Integrity Level Claim Limit (SIL CL) | 3 |
Standards and Regulations
| Designation | Air clearances and creepage distances between the power circuits |
|---|---|
| Standards/regulations | DIN EN 50178, EN 60947-5-1 |
| Rated insulation voltage | 250 V AC |
| Rated surge voltage/insulation | Basic insulation 4 kV between all current paths and housing |
| Safe isolation, reinforced insulation 6 kV between input circuit (A1/A2, I1, I2, I3, MI1, MI2, IN1, IN2, S34, MO1, MO2, RJ45, USB) and the enabling current paths (13/14, 23/24) | |
| Degree of pollution | 2 |
| Overvoltage category | III |
| Shock | 15g |
| Vibration (operation) | 10 Hz ... 150 Hz, 2g |
Environmental Product Compliance
| China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
|---|---|
| No hazardous substances above threshold values |
Classifications
eCl@ss
| eCl@ss 4.0 | 27371102 |
|---|---|
| eCl@ss 4.1 | 27371102 |
| eCl@ss 5.0 | 27371901 |
| eCl@ss 5.1 | 27371901 |
| eCl@ss 6.0 | 27371800 |
| eCl@ss 7.0 | 27371811 |
| eCl@ss 8.0 | 27371811 |
| eCl@ss 9.0 | 27371811 |
UNSPSC
| UNSPSC 6.01 | 30211901 |
|---|---|
| UNSPSC 7.0901 | 39121501 |
| UNSPSC 11 | 39121501 |
| UNSPSC 12.01 | 39121501 |
| UNSPSC 13.2 | 39122331 |
| UNSPSC 18.0 | 39122331 |
| UNSPSC 19.0 | 39122331 |
| UNSPSC 20.0 | 39122331 |
| UNSPSC 21.0 | 39122331 |