Providing reliable machine safeguarding, the Phoenix Contact PSR-MM25-1NO-2DO-24DC-SP 2702356 safety device acts as a critical intermediary in modern industrial safety loops. These hardware units continuously evaluate sensor inputs from guards, light curtains, or motion sensors to halt hazardous motion instantly when an interlock is broken. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Rated control supply voltage DC (EF003980): 24 V
- Voltage type for actuating (EF008242): DC
- With detachable clamps (EF003340): Yes
- Function rotational speed monitoring (EF003430): No
- Function standstill monitoring (EF003431): Yes
- Rated operating frequency (EF007370): 3000 Hz
- With feedback circuit (EF003343): No
- Suitable for safety functions (EF001597): Yes
- With approval for BG BIA (EF004145): No
- With approval according to UL (EF001783): Yes
- Width (EF000008): 12.5 mm
- Height (EF000040): 116.6 mm
- Depth (EF000049): 114.5 mm
More info
▲Key Commercial Data
| Orderkey | 2702356 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 276 (C-6-2017) |
| GTIN | 4055626133218 |
| Weight per Piece (excluding packing) | 146.700 g |
| Custom tariff number | 85389091 |
| Country of origin | DE (Germany) |
Note
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
Ambient conditions
| Ambient temperature (operation) | -20 °C ... 55 °C (observe derating) |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
| Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
| Maximum altitude | max. 2000 m (Above sea level) |
Power supply
| Rated control circuit supply voltage US | 24 V DC -15 % / +10 % |
|---|---|
| Rated control supply current IS | typ. 50 mA |
| Power consumption at US | typ. 1.2 W |
| Inrush current | 5.6 A (Δt = 400 µs at Us) |
| Filter time | 1 ms (at A1 in the event of voltage dips at Us) |
| Protective circuit | Surge protection Suppressor diode |
| Protection against polarity reversal for rated control circuit supply voltage |
Measuring inputs
| Current consumption | max. 0.35 mA (at L1/L2/L3) |
|---|---|
| Voltage input signal | max. 690 V AC/DC (at L1/L2/L3) |
| Limit frequency | max. 3 kHz (At voltages > 2 VRMS) |
Relay outputs: enabling current path
| Output name | Enabling current path |
|---|---|
| Output description | safety-related N/O contacts |
| Number of outputs | 1 (undelayed) |
| Contact type | 1 enabling current path |
| Contact material | AgSnO2 |
| Switching voltage | min. 24 V AC/DC |
| max. 250 V AC/DC (Observe the load curve) | |
| Limiting continuous current | 5 A (observe derating) |
| Inrush current | min. 3 mA |
| max. 5 A | |
| Sq. Total current | 25 A2(observe derating) |
| Switching capacity | min. 72 mW |
| Switching frequency | max. 0.5 Hz |
| Mechanical service life | 10x 106cycles |
| Output fuse | 5 A gL/gG |
Alarm outputs
| Number of outputs | 2 (digital, PNP) |
|---|---|
| Voltage | 23 V DC (US- 1 V) |
| Current | max. 100 mA |
| Maximum inrush current | 500 mA |
| Short-circuit protection | Yes |
Times
| Typical pickup time at US | < 1 s |
|---|---|
| Response time | typ. 20 ms (at 50 Hz input frequency) |
| Delay time range | 0.5 s ... 20 s ±1 % (K1, K2 can be parameterized) |
General
| Nominal operating mode | 100% operating factor |
|---|---|
| Net weight | 146.7 g |
| Mounting position | vertical or horizontal |
| Mounting type | DIN rail mounting |
| Assembly instructions | See derating curve |
| Degree of protection | IP20 |
| Min. degree of protection of inst. location | IP54 |
| Housing material | PBT |
| Housing color | yellow |
| Status display | 4 x LED Bi-Colour |
Connection data
| Connection method | Spring-cage connection |
|---|---|
| pluggable | Yes |
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 1.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 1.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 16 |
| Stripping length | 8 mm |
Safety-related characteristic data
| Stop category | 0 |
|---|---|
| Designation | IEC 61508 - High demand |
| Safety Integrity Level (SIL) | 3 (4 A DC13; 5 A AC15; 17520 switching cycles/year) |
| Designation | EN ISO 13849 |
| Performance level (PL) | e (4 A DC13; 5 A AC15; 17520 switching cycles/year) |
| Category | 3 |
| Designation | EN 62061 |
| Safety Integrity Level Claim Limit (SIL CL) | 3 (4 A DC13; 5 A AC15; 17520 switching cycles/year) |
Standards and Regulations
| Designation | Air clearances and creepage distances between the power circuits |
|---|---|
| Standards/regulations | DIN EN 50178 |
| Rated insulation voltage | 250 V AC |
| 250 V AC | |
| 400 V AC with isolation paths between (L1/L2/L3) and the remaining current paths | |
| 690 V AC (with isolation paths within L1/L2/L3) | |
| Rated surge voltage/insulation | Basic insulation 4 kV: between all current paths and housing Basic insulation 8 kV: between L1 and L2 between L1 and L3 between L2 and L3 |
| Safe isolation, reinforced insulation 6 kV: between A1/A2 and 13/14 between MO/FO and 13/14 Safe isolation, reinforced insulation 8 kV: between L1/L2/L3 and A1/A2 between L1/L2/L3 and MO/FO between L1/L2/L3 and 13/14 | |
| Degree of pollution | 2 |
| Overvoltage category | III |
| Shock | 15g |
| Vibration (operation) | 10 Hz ...150 Hz, 2g |
| Conformance | CE-compliant |
Environmental Product Compliance
| China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
|---|---|
| No hazardous substances above threshold values |