PSR-ME40-4NO-2NC-24DC-SC-SET35 1397653 PHOENIX CONTACT Set of 35 safety relays as contact extension, adjusta..
PSR-ME40-4NO-2NC-24DC-SC-SET35
1397653
PHOENIX CONTACT
1 Pcs.
Automation > Device for monitoring of safety-related circuits
Safety
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
As part of an extensive safety architecture, the Phoenix Contact PSR-ME40-4NO-2NC-24DC-SC-SET35 safety relays serve as contact extensions for complex machine control networks. Extension modules multiply the available enabling paths of a primary safety controller, allowing a single emergency stop signal to safely switch multiple heavy-duty loads across an automated system.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: Safety relays
- Product family: PSRclassic
- Application: Extension module
- Mechanical service life: approx. 10 7 cycles
- Relay type: Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
- Times Typical response time: typ. 40 ms (For U s autostart)
- Typical release time: 50 ms (on demand via A1)
- Delay time range: 0.5 s ... 30 s ±40 %
- Restart time: < 1 s (Boot time)
- Recovery time: Delay time +500 ms
- Maximum power dissipation for nominal condition: 17 W (U S = 26.4 V, I L ² = 72 A², P Total max = 2.6 W + 14.4 W)
- Nominal operating mode: 100% operating factor
- Rated surge voltage/insulation: See section “Insulation coordination”
- Supply Designation: A1/A2
- Rated control circuit supply voltage U S: 24 V DC -15 % / +10 %
- Rated control supply current I S: typ. 77 mA (at U S )
More info
▲| Product type | Safety relays |
| Product family | PSRclassic |
| Application | Extension module |
| Mechanical service life | approx. 107cycles |
| Relay type | Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3 |
| Times | |
| Typical response time | typ. 40 ms (For Usautostart) |
| Typical release time | 50 ms (on demand via A1) |
| Delay time range | 0.5 s ... 30 s ±40 % |
| Restart time | < 1 s (Boot time) |
| Recovery time | Delay time +500 ms |
| Maximum power dissipation for nominal condition | 17 W (US= 26.4 V, IL² = 72 A², PTotal max= 2.6 W + 14.4 W) |
| Nominal operating mode | 100% operating factor |
| Air clearances and creepage distances between the power circuits | |
| Rated insulation voltage | 250 V |
| Rated surge voltage/insulation | See section “Insulation coordination” |
| Supply | |
| Designation | A1/A2 |
| Rated control circuit supply voltage US | 24 V DC -15 % / +10 % |
| Rated control supply current IS | typ. 77 mA (at US) |
| Power consumption at US | typ. 1.85 W |
| Inrush current | < 2.5 A (typically with US, Δt = 1 ms) |
| Filter time | 5 ms (in the event of voltage dips at Us) |
| Protective circuit | Reverse polarity protection; Suppressor diode |
| Digital: K1/K2 | |
| Description of the input | safety-related |
| Number of inputs | 1 |
| Input voltage range "0" signal | 0 V DC ... 5 V DC |
| Input voltage range "1" signal | 20.4 V ... 26.4 V |
| Input current range "0" signal | 0 mA ... 2 mA |
| Filter time | 1 ms (Test pulse width of low test pulses) |
| 1 s (Test pulse rate for low test pulse) | |
| No brightness test pulses / high test pulses permitted. | |
| Max. permissible overall conductor resistance | 50 Ω |
| Protective circuit | Suppressor diode |
| Current consumption | typ. 14 mA |
| Relay: Enabling current paths (27/28, 37/38, 47/48, 57/58) | |
| Output description | 2 N/O contacts each in series, safety-related, floating |
| Number of outputs | 4 |
| Contact switching type | 4 enabling current paths |
| Contact material | AgSnO2 |
| Switching voltage | min. 10 V AC/DC |
| max. 250 V AC | |
| Switching capacity | min. 100 mW |
| Inrush current | min. 10 mA |
| max. 6 A | |
| Switching capacity in accordance with IEC 60947-5-1 | 5 A (AC15) |
| 6 A (DC13) | |
| Limiting continuous current | 6 A (Observe derating and load limit curve) |
| Sq. Total current | 72 A2(observe derating) |
| Switching frequency | max. 0.5 Hz |
| Mechanical service life | 10x 106cycles |
| Output fuse | 10 A gL/gG |
| 4 A gL/gG (for low-demand applications) | |
| Relay: Confirmation current path (15/16) | |
| Output description | Diagnostic contact, 2 NC in series, floating |
| Number of outputs | 1 |
| Contact switching type | 2 N/C contacts in series |
| Contact material | AgSnO2 |
| Switching voltage | min. 10 V AC/DC |
| max. 250 V AC | |
| Switching capacity | min. 100 mW |
| Inrush current | min. 10 mA |
| max. 1 A | |
| Switching capacity in accordance with IEC 60947-5-1 | 1 A (AC15) |
| 1 A (DC13) | |
| Limiting continuous current | 1 A |
| Sq. Total current | 1 A2 |
| Switching frequency | max. 0.5 Hz |
| Mechanical service life | 10x 106cycles |
| Output fuse | 1 A gL/gG |
| Relay: Signaling current path (65/66) | |
| Output description | 2 N/C contacts parallel, non-safety-related, floating |
| Number of outputs | 1 |
| Contact material | AgSnO2 |
| Switching voltage | min. 10 V AC/DC |
| 250 V AC | |
| Switching capacity | min. 100 mW |
| Inrush current | max. 1 A |
| Switching capacity in accordance with IEC 60947-5-1 | 1 A (AC15) |
| 1 A (DC13) | |
| Limiting continuous current | 1 A |
| Sq. Total current | 1 A2 |
| Mechanical service life | 10x 106cycles |
| Output fuse | 1 A (gL/gG) |
| Connection technology | |
| pluggable | yes |
| Conductor connection | |
| Connection method | Screw connection |
| Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross-section AWG | 24 ... 12 |
| Stripping length | 7 mm |
| Screw thread | M3 |
| Tightening torque | 0.5 Nm ... 0.6 Nm |
| Status display | 2 x green LEDs |
| Operating voltage display | 1 x green LED |
| Width | 22.5 mm |
| Height | 112.2 mm |
| Depth | 114.5 mm |
| Housing material | Polyamide |
| Safety data | |
| Stop category | 1 |
| Safety data: EN ISO 13849 | |
| Category | 3 |
| Performance level (PL) | d |
| Safety data: IEC 61508 - High demand | |
| Safety Integrity Level (SIL) | 2 |
| Safety data: IEC 61508 - Low demand | |
| Safety Integrity Level (SIL) | 2 |
| Safety data: EN IEC 62061 | |
| Safety Integrity Level (SIL) | 2 |
| Ambient conditions | |
| Degree of protection | IP20 |
| Min. degree of protection of inst. location | IP54 |
| Ambient temperature (operation) | -20 °C ... 55 °C (observe derating) |
| Ambient temperature (storage/transport) | -40 °C ... 70 °C |
| Maximum altitude | ≤ 2000 m (Above sea level) |
| Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
| Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
| Shock | 15g |
| Vibration (operation) | 10 Hz ... 150 Hz, amplitude 0.15 mm, 2g |
| CE | |
| Identification | CE-compliant |
| Air clearances and creepage distances between the power circuits | |
| Standards/regulations | DIN EN 60947-1 |
| Mounting type | DIN rail mounting |
| Assembly instructions | See derating curve |
| Mounting position | vertical or horizontal |
| Connection method | Screw connection |