View larger
PSR-ME30-4NO-1NC-24DC-SC 1397656 PHOENIX CONTACT Safety relay as contact extension, 4 enabling circuits, 1 f..
PSR-ME30-4NO-1NC-24DC-SC
1397656
PHOENIX CONTACT
1 Pcs.
Automation > Device for monitoring of safety-related circuits
Safety
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A PSR-ME30-4NO-1NC-24DC-SC safety relay as contact extension by Phoenix Contact is utilized in industrial machine safety systems to expand the number of enabling paths available for emergency stop and interlock chains. This electromechanical unit integrates force-guided contacts to safely monitor and interrupt power delivery to hazardous motion zones when a fault or stop condition is triggered. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: Safety relays
- Product family: PSRclassic
- Set comprises: 1397657 PSR-ME30-4NO-1NC-24DC-SC-SET35
- Application: Extension module
- Mechanical service life: approx. 10 7 cycles
- Relay type: Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
- Times Typ. starting time with U s: 20 ms (when controlled via K1/K2)
- Typical release time: 20 ms (when requested via K1/K2)
- Maximum power dissipation for nominal condition: 16.4 W (U K1/K2 = 26.4 V, I L ² = 72 A², P Total max = 2 W + 14.4 W)
- Nominal operating mode: 100% operating factor
- Rated surge voltage/insulation: See section “Insulation coordination”
- Digital: K1/K2 Description of the input: safety-related
- Number of inputs: 1
- Input voltage range "1" signal: 20.4 V ... 26.4 V
- Inrush current: typ. 130 mA (Δt = 800 ms)
- Max. permissible overall conductor resistance: 50 Ω
More info
▲| Product type | Safety relays |
| Product family | PSRclassic |
| Set comprises | 1397657 PSR-ME30-4NO-1NC-24DC-SC-SET35 |
| Application | Extension module |
| Mechanical service life | approx. 107cycles |
| Relay type | Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3 |
| Times | |
| Typ. starting time with Us | 20 ms (when controlled via K1/K2) |
| Typical release time | 20 ms (when requested via K1/K2) |
| Maximum power dissipation for nominal condition | 16.4 W (UK1/K2= 26.4 V, IL² = 72 A², PTotal max= 2 W + 14.4 W) |
| Nominal operating mode | 100% operating factor |
| Air clearances and creepage distances between the power circuits | |
| Rated insulation voltage | 250 V |
| Rated surge voltage/insulation | See section “Insulation coordination” |
| Digital: K1/K2 | |
| Description of the input | safety-related |
| Number of inputs | 1 |
| Input voltage range "1" signal | 20.4 V ... 26.4 V |
| Inrush current | typ. 130 mA (Δt = 800 ms) |
| Max. permissible overall conductor resistance | 50 Ω |
| Protective circuit | Suppressor diode |
| Current consumption | typ. 67 mA |
| Relay: Enabling current paths (13/14, 23/24, 33/34, 43/44) | |
| Output description | 2 N/O contacts each in series, safety-related, floating |
| Number of outputs | 4 |
| Contact switching type | 4 enabling current paths |
| Contact material | AgSnO2 |
| Switching voltage | min. 10 V AC/DC |
| max. 250 V AC | |
| Switching capacity | min. 100 mW |
| Inrush current | min. 10 mA |
| max. 6 A | |
| Switching capacity in accordance with IEC 60947-5-1 | 5 A (AC15) |
| 6 A (DC13) | |
| Limiting continuous current | 6 A (Observe derating and load limit curve) |
| Sq. Total current | 72 A2(observe derating) |
| Switching frequency | max. 0.5 Hz |
| Mechanical service life | 10x 106cycles |
| Output fuse | 10 A gL/gG |
| 4 A gL/gG (for low-demand applications) | |
| Relay: Confirmation current path (11/12) | |
| Output description | Diagnostic contact, 2 NC in series, floating |
| Number of outputs | 1 |
| Contact switching type | 2 N/C contacts in series |
| Contact material | AgSnO2 |
| Switching voltage | min. 10 V AC/DC |
| max. 250 V AC | |
| Switching capacity | min. 100 mW |
| Inrush current | min. 10 mA |
| max. 6 A | |
| Switching capacity in accordance with IEC 60947-5-1 | 1 A (AC15) |
| 1 A (DC13) | |
| Limiting continuous current | 1 A |
| Sq. Total current | 1 A2 |
| Switching frequency | max. 0.5 Hz |
| Mechanical service life | 10x 106cycles |
| Output fuse | 1 A gL/gG |
| Connection technology | |
| pluggable | yes |
| Conductor connection | |
| Connection method | Screw connection |
| Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross-section AWG | 24 ... 12 |
| Stripping length | 7 mm |
| Screw thread | M3 |
| Tightening torque | 0.5 Nm ... 0.6 Nm |
| Operating voltage display | 1 x green LED |
| Width | 22.5 mm |
| Height | 112.2 mm |
| Depth | 114.5 mm |
| Housing material | Polyamide |
| Safety data | |
| Stop category | 0 |
| Safety data: EN ISO 13849 | |
| Category | 3 |
| Performance level (PL) | d |
| Safety data: IEC 61508 - High demand | |
| Safety Integrity Level (SIL) | 2 |
| Safety data: IEC 61508 - Low demand | |
| Safety Integrity Level (SIL) | 2 |
| Safety data: EN IEC 62061 | |
| Safety Integrity Level (SIL) | 2 |
| Ambient conditions | |
| Degree of protection | IP20 |
| Min. degree of protection of inst. location | IP54 |
| Ambient temperature (operation) | -20 °C ... 55 °C (observe derating) |
| Ambient temperature (storage/transport) | -40 °C ... 70 °C |
| Maximum altitude | ≤ 2000 m (Above sea level) |
| Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
| Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
| Shock | 15g |
| Vibration (operation) | 10 Hz ... 150 Hz, 2g |
| CE | |
| Identification | CE-compliant |
| Air clearances and creepage distances between the power circuits | |
| Standards/regulations | DIN EN 60947-1 |
| Mounting type | DIN rail mounting |
| Assembly instructions | See derating curve |
| Mounting position | vertical or horizontal |
| Connection method | Screw connection |