View larger
PSR-MC82-5NO-1NC-1DO-24DC-SP 2702383 PHOENIX CONTACT Extension module
PSR-MC82-5NO-1NC-1DO-24DC-SP
2702383
PHOENIX CONTACT
1 Pcs.
Automation > Device for monitoring of safety-related circuits
Safety
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
This Phoenix Contact PSR-MC82-5NO-1NC-1DO-24DC-SP 2702383 PHOENIX CONTACT Extension module functions as an expansion unit to multiply safe output contacts in industrial safety chains. Devices of this category integrate seamlessly with primary safety controllers to supervise hazardous machine movements. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Model (EF000010): Expansion device
- Suitable for rail mounting (EF003972): Yes
- With detachable clamps (EF003340): Yes
- Type of electric connection (EF003961): Spring clamp connection
- Suitable for monitoring of valves (EF007272): No
- Suitable for monitoring of tactile sensors (EF007271): No
- Suitable for monitoring of magnetic switches (EF007266): No
- Suitable for monitoring of proximity switches (EF007267): No
- With start input (EF003342): No
- With muting function (EF004057): No
- With feedback circuit (EF003343): No
- Release-delay (EF001129): 0.05 s
- With approval for BG BIA (EF004145): No
- With approval according to UL (EF001783): No
- Width (EF000008): 17.5 mm
- Height (EF000040): 116.6 mm
More info
▲Key Commercial Data
| Orderkey | 2702383 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 259 (C-6-2017) |
| GTIN | 4055626145488 |
| Weight per Piece (excluding packing) | 210.300 g |
| Custom tariff number | 85371098 |
| Country of origin | DE (Germany) |
Note
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
Ambient conditions
| Ambient temperature (operation) | -20 °C ... 60 °C (observe derating) |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
| Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
| Maximum altitude | max. 2000 m (Above sea level) |
Power supply
| Rated control circuit supply voltage US | 24 V DC -20 % / +25 % |
|---|---|
| 19.2 V DC ... 30 V DC | |
| Rated control supply current IS | typ. 80 mA |
| Power consumption at US | typ. 1.92 W |
| Inrush current | 30 mA (Δt = 7 ms at Us) |
| Filter time | 4 ms (at A1 in the event of voltage dips at Us) |
| max. 1 ms (at A1/A2, test pulse width, blanking pulses/dark test) | |
| 5 ms (at A1/A2, test pulse rate, blanking pulses/dark test) | |
| Where test pulse width | |
| max. 1 ms (at A1/A2, test pulse width, switch-on pulses/light test) | |
| 10 ms (at A1/A2; test pulse rate; switch-on pulses/light test) | |
| Deactivate switch-on pulses/light tests for safety applications. | |
| Protective circuit | Surge protection Suppressor diode |
| Reverse polarity protection Universal diode |
Relay outputs: enabling current path
| Output name | Enabling current path |
|---|---|
| Output description | safety-related N/O contacts |
| Number of outputs | 5 (undelayed) |
| Contact type | 5 enabling current paths |
| Contact material | AgSnO2 |
| Switching voltage | min. 5 V AC/DC |
| max. 24 V DC (Enabling current path 23/24) | |
| max. 250 V AC/DC (all other enabling current paths, observe load curve) | |
| Limiting continuous current | 6 A (observe derating) |
| Inrush current | min. 10 mA |
| max. 6 A | |
| Sq. Total current | 64 A2(observe derating) |
| Switching capacity | min. 50 mW |
| Switching frequency | 0.5 Hz |
| Mechanical service life | 10x 106cycles |
| Output fuse | 10 A gL/gG |
| 6 A gL/gG (for low-demand applications) |
Relay outputs: return current/signaling current path
| Output name | Confirmation current path |
|---|---|
| Output description | Safety-related N/C contacts |
| Number of outputs | 1 (undelayed) |
| Contact type | 1 confirmation current path |
| Contact material | AgSnO |
| Switching voltage | min. 5 V AC/DC |
| max. 24 V DC | |
| Limiting continuous current | 100 mA |
| Inrush current | max. 100 mA |
| min. 10 mA | |
| Switching capacity | min. 50 mW |
| Switching frequency | max. 0.5 Hz |
| Mechanical service life | 10x 106cycles |
Alarm outputs
| Output description | non-safety-related |
|---|---|
| Number of outputs | 1 (digital, PNP) |
| Voltage | typ. 23 V DC (US- 1 V) |
| Current | max. 100 mA |
| Maximum inrush current | 500 mA (Δt = 1 ms at Us) |
| Short-circuit protection | Yes |
Times
| Typical pickup time at US | < 50 ms (when controlled via A1/A2) |
|---|---|
| Typical response time at US | < 50 ms |
| Typical release time at US | < 25 ms (when controlled via A1/A2) |
| Recovery time | < 100 ms |
General
| Relay type | Electromechanical relay with forcibly guided contacts in accordance with EN 50205 |
|---|---|
| Nominal operating mode | 100% operating factor |
| Net weight | 210.3 g |
| Mounting position | vertical or horizontal |
| Mounting type | DIN rail mounting |
| Assembly instructions | See derating curve |
| Degree of protection | IP20 |
| Min. degree of protection of inst. location | IP54 |
| Housing color | yellow |
| Status display | 2 x green LEDs |
Connection data
| Connection method | Spring-cage connection |
|---|---|
| pluggable | Yes |
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 1.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 1.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 16 |
| Stripping length | 8 mm |
Safety-related characteristic data
| Stop category | 0 |
|---|---|
| Designation | IEC 61508 - High demand |
| Safety Integrity Level (SIL) | 3 (In conjunction with suitable evaluating device) |
| Designation | IEC 61508 - Low demand |
| Safety Integrity Level (SIL) | 3 (In conjunction with suitable evaluating device) |
| Designation | EN ISO 13849 |
| Performance level (PL) | e (In conjunction with suitable evaluating device) |
| Category | 4 (In conjunction with suitable evaluating device) |
| Designation | EN 62061 |
| Safety Integrity Level Claim Limit (SIL CL) | 3 (In conjunction with suitable evaluating device) |
Standards and Regulations
| Designation | Air clearances and creepage distances between the power circuits |
|---|---|
| Standards/regulations | DIN EN 50178 |
| Rated insulation voltage | 250 V AC |
| 250 V AC | |
| Rated surge voltage/insulation | Basic insulation 4 kV between all current paths |
| Basic insulation 4 kV between all current paths and housing | |
| Safe isolation, reinforced insulation 6 kV between input circuits and enabling current paths 33/34, 43/44, and 63/64 | |
| Degree of pollution | 2 |
| Overvoltage category | III |
| Shock | 15g (In the event of stress caused by shock, contact reactions are possible for up to 6 ms.) |
| Vibration (operation) | 10 Hz ...150 Hz, 2g (In the event of stress caused by vibration, contact reactions are possible for up to 1 ms.) |
| Conformance | CE-compliant |
Environmental Product Compliance
| China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
|---|---|
| No hazardous substances above threshold values |