A Phoenix Contact PSR-MC42-2NO-1DO-24DC-SC safety relay with IO-Link integration monitors emergency stops and safety doors while providing diagnostic data to higher-level control systems. This basic safety device ensures safe interruption of machine power circuits while feeding operational status parameters directly through modern communication networks. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Model (EF000010): Basic device
- Suitable for rail mounting (EF003972): Yes
- With detachable clamps (EF003340): Yes
- Type of electric connection (EF003961): Screw connection
- Suitable for monitoring of position switches (EF007270): Yes
- Suitable for monitoring of valves (EF007272): No
- Suitable for monitoring of tactile sensors (EF007271): No
- Suitable for monitoring of magnetic switches (EF007266): Yes
- Suitable for monitoring of proximity switches (EF007267): No
- With start input (EF003342): No
- With muting function (EF004057): No
- With feedback circuit (EF003343): Yes
- Release-delay (EF001129): 0.22 s
- With approval for BG BIA (EF004145): No
- With approval according to UL (EF001783): No
- Width (EF000008): 17.5 mm
More info
▲Key Commercial Data
| Orderkey | 2702901 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 224 (C-6-2019) |
| GTIN | 4055626458540 |
| Weight per Piece (excluding packing) | 180.000 g |
| Custom tariff number | 85371098 |
| Country of origin | DE (Germany) |
Note
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 60 °C (observe derating) |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
| Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
| Maximum altitude | ≤ 2000 m (Above sea level) |
Power supply
| Designation | A1/A2 |
|---|---|
| Rated control circuit supply voltage US | 24 V DC -20 % / +25 % (provide external protection) |
| Rated control supply current IS | typ. 60 mA |
| Power consumption at US | typ. 1.44 W |
| Inrush current | typ. 2.5 A (Δt = 500 µs at Us) |
| Filter time | 1 ms (at A1 in the event of voltage dips at Us) |
| Protective circuit | Serial protection against polarity reversal Suppressor diode |
Supply of the IO-Link ports
| Designation | L+/L- |
|---|---|
| Nominal voltage for I/O supply | 24 V DC -20 % / +25 % (is provided via the IO-Link interface of the IO-Link master.) |
| Current consumption | typ. 16 mA |
| Type of protection | Serial protection against polarity reversal |
| Protective circuit/component | Suppressor diode |
Digital inputs
| Input name | Sensor circuit S0 |
|---|---|
| S12, S22 | |
| Description of the input | safety-related sensor inputs |
| NPN (S12), NPN/PNP (S22) | |
| Number of inputs | 2 |
| Input voltage range "0" signal | 0 V DC ... 5 V DC (S12) |
| For S22, see note in “Signal generator connection versions” section. | |
| Input voltage range "1" signal | 11 V DC ... 30 V DC |
| Input current range "0" signal | 0 mA ... 2 mA (S12, S22) |
| Inrush current | < 5 mA (typ. with USat S12, Δt = 150 ms) |
| < 5 mA (typically with USat S22/24 V, Δt = 500 µs) | |
| > -5 mA (typically with USat S22/0 V, Δt = 500 µs) | |
| Current consumption | < 5 mA (Typically with USat S12) |
| < 5 mA (typically with USat S22/24 V) | |
| > -5 mA (typically with USat S22/0 V) | |
| Filter time | 1.5 ms (Test pulse width of low test pulses) |
| Test pulse rate = 5 x Test pulse width | |
| Deactivate switch-on pulses/light tests for safety applications. | |
| Max. permissible overall conductor resistance | 150 Ω |
| Concurrence input 1/2 | ∞ |
| Protective circuit/component | Suppressor diode |
| Input name | Sensor circuit S1 |
| S32, S42 | |
| Description of the input | safety-related sensor inputs |
| NPN | |
| Number of inputs | 2 |
| Input voltage range "0" signal | 0 V DC ... 5 V DC |
| Input voltage range "1" signal | 11 V DC ... 30 V DC |
| Input current range "0" signal | 0 mA ... 2 mA |
| Inrush current | < 20 mA (typically with US) |
| Current consumption | < 5 mA (typically with US) |
| Filter time | max. 1.5 ms (Test pulse width of low test pulses) |
| Test pulse rate = 5 x Test pulse width | |
| Deactivate switch-on pulses/light tests for safety applications. | |
| Max. permissible overall conductor resistance | 150 Ω |
| Concurrence input 1/2 | ∞ |
| Protective circuit/component | Suppressor diode |
| Input name | Diagnostic input |
| DGN | |
| Description of the input | non-safety-related |
| Number of inputs | 1 |
| Input voltage range | 0 V DC ... 30 V DC |
| Current consumption | typ. 30 mA |
| Protective circuit/component | Suppressor diode |
| Input name | Start circuit |
| S34 | |
| Description of the input | NPN (manual start), PNP (autostart) |
| Number of inputs | 1 |
| Input voltage range "1" signal | 19.2 V DC ... 30 V DC (manual start, autostart: 0 V) |
| Inrush current | < 10 mA (typically with US, Δt = 100 ms) |
| Current consumption | < 5 mA (typically with USat S34/24 V) |
| > -5 mA (typically with USat S34/0 V) | |
| Max. permissible overall conductor resistance | 150 Ω |
| Protective circuit/component | Suppressor diode |
IO-Link inputs
| Designation | IO-Link |
|---|---|
| Specification | Version 1.1 |
| Transmission speed | 230 kbps (COM3) |
| Cycle Time | 5 ms |
| Process data update | 5 ms |
| Amount of process data | max. 31 Byte (Input data) |
| max. 16 Byte (Output data) | |
| Number of ports | 1 |
| Connection method | Screw connection |
| Connection technology | 3-wire |
| Port type | Class A |
| Input name | C/Q |
| Description of the input | IO-Link switching and communication cable |
| Number of inputs | 1 |
Relay outputs: enabling current path
| Output name | Enabling current path |
|---|---|
| 13/14, 23/24 | |
| Output description | safety-related N/O contacts |
| 2 NO contacts each in series, without delay, floating | |
| Number of outputs | 2 (undelayed) |
| Contact type | 2 enabling current paths |
| Contact material | AgSnO2 |
| Switching voltage | min. 12 V AC/DC |
| max. 250 V AC/DC (Observe the load curve) | |
| Limiting continuous current | 6 A |
| Inrush current | min. 3 mA |
| max. 6 A | |
| Sq. Total current | 72 A2(observe derating) |
| Switching capacity | min. 60 mW |
| Switching frequency | 0.5 Hz |
| Mechanical service life | 10x 106cycles |
| Switching capacity according to IEC 60947-5-1 | 4 A (24 V (DC13)) |
| 5 A (250 V (AC15)) | |
| Output fuse | 6 A gL/gG |
| 4 A gL/gG (for low-demand applications) |
Alarm outputs
| Designation | M1 |
|---|---|
| Output description | PNP |
| non-safety-related | |
| Number of outputs | 1 |
| Voltage | approx. 22 V DC (Us- 2 V) |
| Current | max. 100 mA |
| Maximum inrush current | 500 mA (Δt = 1 ms at Us) |
| Protective circuit/component | Suppressor diode |
Times
| Typical pickup time at US | < 250 ms (when controlled via A1) |
|---|---|
| Typical response time at US | < 220 ms (automatic start) |
| < 175 ms (manual, monitored start) | |
| Typical release time at US | < 20 ms (on demand via the sensor circuit) |
| < 20 ms (on demand via A1) | |
| Restart time | < 1 s (Boot time) |
| Recovery time | < 500 ms |
General
| Relay type | Electromechanical relay with forcibly guided contacts in accordance with IEC/EN 61810-3 (EN 50205) |
|---|---|
| Nominal operating mode | 100% operating factor |
| Net weight | 157.28 g |
| Mounting position | vertical or horizontal |
| Mounting type | DIN rail mounting |
| Assembly instructions | See derating curve |
| Degree of protection | IP20 |
| Min. degree of protection of inst. location | IP54 |
| Housing material | PBT |
| Housing color | yellow |
| Operating voltage display | 1 x green, yellow, red LED |
| Status display | 5x LED green |
Connection data
| Connection method | Screw connection |
|---|---|
| pluggable | Yes |
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 2.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 12 |
| Stripping length | 7 mm |
| Screw thread | M3 |
| Torque | 0.5 Nm ... 0.6 Nm |
Safety-related characteristic data
| Stop category | 0 |
|---|---|
| Designation | IEC 61508 - High demand |
| Safety Integrity Level (SIL) | 3 |
| Designation | IEC 61508 - Low demand |
| Safety Integrity Level (SIL) | 3 |
| Designation | EN ISO 13849 |
| Performance level (PL) | e (4 A DC13; 5 A AC15; 8760 switching cycles/year) |
| Category | 4 |
| Designation | EN 62061 |
| Safety Integrity Level Claim Limit (SIL CL) | 3 |
Standards and Regulations
| Designation | Air clearances and creepage distances between the power circuits |
|---|---|
| Standards/regulations | DIN EN 60947-1 |
| Rated insulation voltage | 320 V |
| 320 V | |
| Rated surge voltage/insulation | Basic insulation 4 kV between all current paths and housing |
| Safe isolation, reinforced insulation 4 kV between input circuit and enabling current path (13/14) and enabling current path (23/24) | |
| Degree of pollution | 2 |
| Overvoltage category | II |
| Shock | 15g |
| Vibration (operation) | 10 Hz ... 150 Hz, 2g |
| Conformance | CE-compliant |
Environmental Product Compliance
| REACh SVHC | Lead 7439-92-1 |
|---|---|
| China RoHS | Environmentally Friendly Use Period = 50 |
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |