View larger
Images are for illustrative purposes only. Please refer to data sheet for details
PSR-MC38-2NO-1DO-24DC-SC 1009831 PHOENIX CONTACT Safety relay for emergency stop, safety doors and light gri..
PSR-MC38-2NO-1DO-24DC-SC
1009831
PHOENIX CONTACT
1 Pcs.
Safety relay for emergency stop, safety doors and light grids up to SILCL 3, Cat. 4, PL e, 1- or 2-channel operation, automatic or manual, monitored start, 2 enabling current paths, 1 signal output, TBUS interface, U
Safety relay for emergency stop, protection doors and light barrier up to SIL 3, cat. 4, PL e, 1 or 2 channel operation, automatic or manual, monitored start, 2 trip circuits, 1 message output, TBUS interface, US = 24 V DC, plug-in screw terminal
Automation > Device for monitoring of safety-related circuits
Safety
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact PSR-MC38-2NO-1DO-24DC-SC safety relay for emergency stop, safety doors and light grids manages protective circuit signals to safeguard machine operators from dangerous mechanical movements.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Model (EF000010): Basic device
- Suitable for rail mounting (EF003972): Yes
- With detachable clamps (EF003340): Yes
- Type of electric connection (EF003961): Screw connection
- Suitable for monitoring of position switches (EF007270): Yes
- Suitable for monitoring of valves (EF007272): No
- Suitable for monitoring of tactile sensors (EF007271): No
- Suitable for monitoring of magnetic switches (EF007266): Yes
- Suitable for monitoring of proximity switches (EF007267): No
- With start input (EF003342): No
- With muting function (EF004057): No
- With feedback circuit (EF003343): Yes
- Release-delay (EF001129): 0.2 s
- With approval for BG BIA (EF004145): No
- With approval according to UL (EF001783): No
- Width (EF000008): 22.5 mm
More info
▲Key Commercial Data
| Orderkey | 1009831 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 223 (C-6-2019) |
| GTIN | 4055626482705 |
| Weight per Piece (excluding packing) | 200.000 g |
| Custom tariff number | 85371098 |
| Country of origin | DE (Germany) |
Back to top
Back to top
Back to top
Back to top
Back to top
Back to top
Back to top
Back to top
Back to top
Back to top
Back to top
Back to top
Back to top
Note
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
Ambient conditions
| Ambient temperature (operation) | -20 °C ... 55 °C (observe derating) |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 70 °C |
| Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
| Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
| Maximum altitude | ≤ 2000 m (Above sea level) |
Power supply
| Designation | A1/A2 |
|---|---|
| Rated control circuit supply voltage US | 24 V DC -15 % / +10 % (provide external protection) |
| Rated control supply current IS | typ. 75 mA |
| Power consumption at US | typ. 1.8 W |
| Inrush current | < 4 A (Δt = 3 ms at Us) |
| Filter time | 20 ms (at A1 in the event of voltage dips at Us) |
| Protective circuit | Serial protection against polarity reversal Suppressor diode |
Digital inputs
| Input name | Sensor circuit |
|---|---|
| S10, S12, S13, S22 | |
| Description of the input | safety-related sensor inputs |
| NPN (S10, S12, S13), PNP (S22) | |
| Number of inputs | 4 |
| Input voltage range "1" signal | 20.4 V DC ... 26.4 V DC |
| Inrush current | < 40 mA (typ. with USat S10) |
| < 300 mA (typ. with USat S12, Δt = 150 ms) | |
| < 3 mA (Typically with USat S13) | |
| > -300 mA (Typically with USat S22, Δt = 150 ms) | |
| Current consumption | 40 mA (typ. with USat S10) |
| 45 mA (Typically with USat S12) | |
| 3 mA (Typically with USat S13) | |
| -35 mA (Typically with USat S22, Δt = 150 ms) | |
| Filter time | 2 ms (At S10, S12, S13; test pulse width of low test pulses) |
| 1 ms (At S10, S12, S13; test pulse rate of low test pulses) | |
| No brightness test pulses / high test pulses permitted. | |
| Max. permissible overall conductor resistance | 50 Ω |
| Concurrence input 1/2 | ∞ |
| Protective circuit/component | Suppressor diode |
| Input name | Start circuit |
| Y1, S34, S35 | |
| Description of the input | non-safety-related |
| NPN | |
| Number of inputs | 3 |
| Input voltage range "1" signal | 20.4 V DC ... 26.4 V DC |
| Inrush current | < 60 mA (Typically with USat Y1, Δt = 150 ms) |
| < 270 mA (Typically with USat S34, Δt = 15 ms) | |
| < 80 mA (Typically with USat S35, Δt = 25 ms) | |
| Current consumption | typ. 10 mA (Typically with USat Y1) |
| typ. 34 µA (Typically with USat S35) | |
| Max. permissible overall conductor resistance | 50 Ω |
| Protective circuit/component | Suppressor diode |
Relay outputs: enabling current path
| Output name | Enabling current path |
|---|---|
| 13/14, 23/24 | |
| Output description | safety-related N/O contacts |
| 2 NO contacts each in series, without delay, floating | |
| Number of outputs | 2 (undelayed) |
| Contact type | 2 enabling current paths |
| Contact material | AgSnO2 |
| Switching voltage | min. 10 V AC/DC |
| max. 250 V AC/DC (Observe the load curve) | |
| Limiting continuous current | 6 A |
| Inrush current | min. 10 mA |
| max. 6 A | |
| Sq. Total current | 72 A2(observe derating) |
| Switching capacity | min. 100 mW |
| Switching frequency | max. 0.5 Hz |
| Mechanical service life | 10x 106cycles |
| Switching capacity according to IEC 60947-5-1 | 5 A (24 V (DC13)) |
| 5 A (250 V (AC15)) | |
| Output fuse | 10 A gL/gG |
| 4 A gL/gG (for low-demand applications) |
Alarm outputs
| Designation | Y30 |
|---|---|
| Output description | PNP |
| non-safety-related | |
| Number of outputs | 1 |
| Voltage | approx. 23.9 V DC (Us- 0.1 V) |
| Current | max. 100 mA |
| Maximum inrush current | 500 mA (Δt = 1 ms at Us) |
| Protective circuit/component | Suppressor diode |
Times
| Typical pickup time at US | 200 ms (when controlled via A1) |
|---|---|
| Typical response time at US | 200 ms (automatic start) |
| 30 ms (manual, monitored start) | |
| Typical release time at US | 25 ms (when actuation is via the sensor circuit) |
| 60 ms (when controlled via A1) | |
| Restart time | < 1 s (Boot time) |
| Recovery time | < 500 ms |
General
| Relay type | Electromechanical relay with forcibly guided contacts in accordance with EN 50205 |
|---|---|
| Nominal operating mode | 100% operating factor |
| Net weight | 169.38 g |
| Mounting position | vertical or horizontal |
| Mounting type | DIN rail mounting |
| Assembly instructions | See derating curve |
| Degree of protection | IP20 |
| Min. degree of protection of inst. location | IP54 |
| Housing material | PBT |
| Housing color | yellow |
| Operating voltage display | 1 x green LED |
| Status display | 4 x green LEDs |
Connection data
| Connection method | Screw connection |
|---|---|
| pluggable | Yes |
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 2.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 12 |
| Stripping length | 7 mm |
| Screw thread | M3 |
| Torque | 0.5 Nm ... 0.6 Nm |
Safety-related characteristic data
| Stop category | 0 |
|---|---|
| Designation | IEC 61508 - High demand |
| Safety Integrity Level (SIL) | 3 |
| Designation | IEC 61508 - Low demand |
| Safety Integrity Level (SIL) | 3 |
| Designation | EN ISO 13849 |
| Performance level (PL) | e |
| Category | 4 (5 A DC13; 5 A AC15; 8760 switching cycles/year) |
| Designation | EN 62061 |
| Safety Integrity Level Claim Limit (SIL CL) | 3 |
Standards and Regulations
| Designation | Air clearances and creepage distances between the power circuits |
|---|---|
| Standards/regulations | DIN EN 50178 |
| Rated insulation voltage | 250 V |
| 250 V | |
| Rated surge voltage/insulation | Safe isolation, reinforced insulation 6 kV between input circuit and enabling current path (13/14) and enabling current path (23/24) Basic insulation 4 kV between all current paths and housing |
| Degree of pollution | 2 |
| Overvoltage category | III |
| Shock | 15g |
| Vibration (operation) | 10 Hz ... 150 Hz, 2g |
| Conformance | CE-compliant |
Environmental Product Compliance
| REACh SVHC | Lead 7439-92-1 |
|---|---|
| China RoHS | Environmentally Friendly Use Period = 50 |
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |