PSR-MC31-2SDO-1DO-24DC-SP 1015503 PHOENIX CONTACT Safety relay module for safety shut-off mats, switching st..
PSR-MC31-2SDO-1DO-24DC-SP
1015503
PHOENIX CONTACT
1 Pcs.
Automation > Device for monitoring of safety-related circuits
Safety
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Functioning as a PSR-MC31-2SDO-1DO-24DC-SP 1015503 PHOENIX CONTACT Safety relay module for safety shut-off mats, switching st.., this unit is designed to monitor pressure mats and safety sensors to safeguard hazard zones around automated industrial machinery. It processes signals from protective devices to cut power safely when triggered. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Model (EF000010): Basic device
- Suitable for rail mounting (EF003972): Yes
- With detachable clamps (EF003340): Yes
- Type of electric connection (EF003961): Spring clamp connection
- Suitable for monitoring of position switches (EF007270): Yes
- Suitable for monitoring of valves (EF007272): No
- Suitable for monitoring of tactile sensors (EF007271): No
- Suitable for monitoring of magnetic switches (EF007266): Yes
- Suitable for monitoring of proximity switches (EF007267): No
- With start input (EF003342): No
- With muting function (EF004057): No
- With feedback circuit (EF003343): No
- Release-delay (EF001129): 0.2 s
- With approval for BG BIA (EF004145): No
- With approval according to UL (EF001783): No
- Width (EF000008): 12.5 mm
More info
▲Note
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
Ambient conditions
| Ambient temperature (operation) | -40 °C ... 70 °C (observe derating) |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 70 °C |
| Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
| Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
| Maximum altitude | ≤ 2000 m (Above sea level) |
Power supply
| Designation | A1/A2 |
|---|---|
| Rated control circuit supply voltage US | 24 V DC -20 % / +25 % (provide external protection) |
| Rated control supply current IS | typ. 54 mA (No load) |
| Power consumption at US | typ. 1.3 W |
| Inrush current | < 5 A (Δt = 200 µs at Us) |
| Filter time | 1 ms (For the logic. At A1 in the event of voltage dips at Us) |
| Protective circuit | Parallel protection against polarity reversal Suppressor diode Provide external protection, see safety notes. Fuse type: 5 A FF |
Digital inputs
| Input name | Sensor circuit |
|---|---|
| S10, S12, S22 | |
| Description of the input | safety-related sensor inputs |
| NPN, IEC 61131-2 type 3 (S10, S12) PNP (S22) | |
| Number of inputs | 3 |
| Input voltage range "0" signal | 0 V DC ... 5 V DC (S10, S12) |
| S22 open | |
| Input voltage range "1" signal | 11 V DC ... 30 V DC (S10, S12) |
| 0 V ... 0 V (S22) | |
| Input current range "0" signal | 0 mA ... 2 mA (S10, S12) |
| Inrush current | < 10 mA (Typically with USat S10/S12, Δt = 500 µs) |
| > -5 mA (typ. with USat S22, Δt = 500 µs) | |
| Current consumption | 4 mA (S10, S12) |
| -4 mA (S22) | |
| Filter time | max. 1.5 ms (Test pulse width of low test pulses) |
| Test pulse rate = 5 x Test pulse width | |
| Does not apply for S22 | |
| Deactivate switch-on pulses/light tests for safety applications. | |
| Max. permissible overall conductor resistance | 150 Ω |
| Concurrence input 1/2 | ∞ |
| Protective circuit/component | Suppressor diode |
| Input name | Start circuit |
| S34, S35 | |
| Description of the input | non-safety-related |
| NPN | |
| Number of inputs | 2 |
| Input voltage range "1" signal | 19.2 V DC ... 30 V DC |
| Inrush current | < 10 mA (Typically with US, Δt |
| Current consumption | < 7 mA (Typically with USat S34) |
| < 5 mA (Typically with USat S35) | |
| Max. permissible overall conductor resistance | 150 Ω |
| Protective circuit/component | Suppressor diode |
| Input name | External release |
| S36 | |
| Description of the input | safety-related |
| NPN, IEC 61131-2, type 3 | |
| Number of inputs | 1 |
| Input voltage range "0" signal | 0 V DC ... 5 V DC |
| Input voltage range "1" signal | 11 V DC ... 30 V DC |
| Current consumption | 7 mA |
| Protective circuit/component | Suppressor diode |
Digital outputs
| Output name | 14, 24 |
|---|---|
| Output description | Safety-related digital outputs |
| PNP, IEC 61131-2 Type 2 | |
| Number of outputs | 2 |
| Output voltage | ≥ 23 V DC (Us- 1 V) |
| Output current | max. 2.4 A |
| Inrush current | max. 4.8 A (Δt = 10 ms) |
| Output voltage when switched off | < 5 V DC (in the safe state) |
| Leakage current | max. 1 mA (in the safe state) |
| Ohmic load | min. 12 Ω |
| Max. capacitive load | max. 10 µF (2.4 A load) |
| max. 4.7 µF (1 A load) | |
| Max. inductive load | max. 1 H |
| Min. load current | 2 mA |
| Switching frequency | 1 Hz (Resistive, inductive, capacitive) |
| Type of protection | Freewheeling circuit for inductive loads |
| Limitation of the voltage induced on circuit interruption | max. 50 V |
Alarm outputs
| Designation | M1 |
|---|---|
| Output description | PNP |
| non-safety-related | |
| Number of outputs | 1 |
| Voltage | approx. 22 V DC (Us- 2 V) |
| Current | max. 100 mA |
| Maximum inrush current | 500 mA (Δt = 1 ms at Us) |
| Protective circuit/component | Suppressor diode |
| Short-circuit protection | Yes |
Times
| Typical pickup time at US | < 200 ms (with Uswhen controlled via A1) |
|---|---|
| Typical response time at US | < 200 ms (automatic start) |
| < 175 ms (manual, monitored start) | |
| Response time | < 10 ms (Take the extension of the response time into consideration if you switch several devices in sequence.) |
| Restart time | < 250 ms (Boot time) |
| Recovery time | 250 ms (following demand of the safety function) |
General
| Nominal operating mode | 100% operating factor |
|---|---|
| Net weight | 104.382 g |
| Mounting position | vertical or horizontal |
| Mounting type | DIN rail mounting |
| Assembly instructions | See derating curve |
| Degree of protection | IP20 |
| Min. degree of protection of inst. location | IP54 |
| Housing material | PBT |
| Housing color | yellow |
| Operating voltage display | 1 x green LED |
| Status display | 3 x green LED |
| Indication | 1 x red LED |
Connection capacity
| Connection method | Push-in spring connection |
|---|---|
| pluggable | Yes |
| Conductor cross section solid | 0.2 mm² ... 1.5 mm² |
| Conductor cross section flexible | 0.2 mm² ... 1.5 mm² |
| Conductor cross section AWG / kcmil | 24 ... 16 |
| Conductor cross section flexible, with ferrule without plastic sleeve | 0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6) |
| Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6) |
| Stripping length | 8 mm |
Safety-related characteristic data
| Stop category | 0 |
|---|---|
| Designation | IEC 61508 - High demand |
| Safety Integrity Level (SIL) | 3 |
| Designation | EN ISO 13849 |
| Performance level (PL) | e |
| Category | 4 |
| Designation | EN 62061 |
| Safety Integrity Level Claim Limit (SIL CL) | 3 |
Standards and Regulations
| Designation | Air clearances and creepage distances between the power circuits |
|---|---|
| Standards/regulations | DIN EN 50178, EN 60947-5-1 |
| Rated insulation voltage | 50 V |
| 50 V AC | |
| Rated surge voltage/insulation | Basic insulation 4 kV between all current paths and housing |
| Degree of pollution | 2 |
| Overvoltage category | III |
| Shock | 30g |
| Vibration (operation) | 10 Hz ... 150 Hz, 5g |
| Conformance | CE-compliant |
Environmental Product Compliance
| REACh SVHC | Lead 7439-92-1 |
|---|---|
| China RoHS | Environmentally Friendly Use Period = 50 |
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |