PHOENIX CONTACT PSR-M-GW-CAN-XC-PI PSR-M-GW-CAN-XC-PI 1337853 PHOENIX CONTACT Link gateway for connection of a basic PSR-M module to a higher c.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

PSR-M-GW-CAN-XC-PI 1337853 PHOENIX CONTACT Link gateway for connection of a basic PSR-M module to a higher c..

PSR-M-GW-CAN-XC-PI

1337853

PHOENIX CONTACT

1 Pcs.

Link gateway for connection of a basic PSR-M module to a higher control system, CANopen, TBUS interface, plug-in push-in terminal, TBUS connector included Gateway for connecting a PSR-M base module to a higher-level controller, CANopen®, TBUS interface, plug-in push-in terminal block, including TBUS connector

Automation > Fieldbus, decentr. periphery - communication module
Safety

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Enabling communication between safety modules and higher-level networks, this PSR-M-GW-CAN-XC-PI 1337853 PHOENIX CONTACT Link gateway for connection of a basic PSR-M module to a higher c.. acts as a protocol bridge in machine safety architectures. Gateways of this type coordinate diagnostic and operational data across diverse industrial fieldbuses. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Product Type: Gateway/proxy
  • Maximum power dissipation under nominal conditions: 1 W
  • Duty cycle report: 100 % ED
  • Interfaces: TBUS support rails for connection to the master module, included in the scope of delivery
  • Impulse voltage sizing/isolation: Basic insulation 4 kV
  • Feeding Denomination: A1/A2
  • Supply voltage of the nominal control circuit U S: 19.2 V DC ... 28.8 V DC
  • Supply voltage of the U sizing control circuit S: 24 V DC -20 % / +20 % (external protection, typical 4 A)
  • Supply, control, dimensioning current I S: tip. 35 mA (without mains connection)
  • U-shaped power draw S: tip. 1 W (with mains connection)
  • Instantaneous current: 11.194 A (Δt = 2 ms with U s )
  • Filter Time: tip. 5 ms (in the presence of voltage drops with U s )
  • Protection Circuit: Serial reverse polarity protection
  • Link: Push-in connection
  • Stripping length: 10 mm
  • Conductor cross-section AWG: (converted according to IEC)

More info

Technical data

Article features
Product TypeGateway/proxy

Electrical characteristics
Maximum power dissipation under nominal conditions1 W
Duty cycle report100 % ED
InterfacesTBUS support rails for connection to the master module, included in the scope of delivery
Air and surface distances between circuits
Rated insulation voltage250 V AC
Impulse voltage sizing/isolationBasic insulation 4 kV
Feeding
DenominationA1/A2
Supply voltage of the nominal control circuit US19.2 V DC ... 28.8 V DC
Supply voltage of the U sizing control circuitS24 V DC -20 % / +20 % (external protection, typical 4 A)
Supply, control, dimensioning current IStip. 35 mA (without mains connection)
tip. 40 mA (with mains connection)
U-shaped power drawStip. 1 W (with mains connection)
Instantaneous current11.194 A (Δt = 2 ms with Us)
Filter Timetip. 5 ms (in the presence of voltage drops with Us)
Protection CircuitSerial reverse polarity protection

Connection data
LinkPush-in connection
Stripping length10 mm
Conductor cross-section AWG(converted according to IEC)

Interfaces
Data: Network Interface
Communication protocolCANopen®
Link9-pin D-SUB socket
Number of connections1
Transmission speedmax. 1 MBit/s
Data: Service Interface
LinkUSB 2.0 Hi-Speed
Number of connections1
Data: Local bus
notevia the PSR TBUS rail bus connector

Signalling
Status Reporting1 x LED (Green), 1 x LED (Green, Red) 1 x LED (Red)
Operating voltage indication1 x Green LEDs
Error reporting2 x LED (Red)

dimensions
width22.61 mm
height107.74 mm
Depth115.95 mm

Material information
Housing MaterialUnreinforced PA polyamide

Environmental and electrical life conditions
Environmental conditions
Degree of protectionIp20
Degree of protection Installation location min.IP54
Ambient temperature (operating)-10 °C ... 70 °C (take into account derating)
Ambient temperature (storage/transport)-20 °C ... 85 °C
height≤ 2000 m (on NN)
Max. humidity. Permitted (storage/transport)95 % (non-condensing)
Maximum permissible humidity (operation)95 % (non-condensing)
Shock10g for Δt = 16 ms (shock resistance, 1000 shocks in each direction)
Vibration (operation)10 Hz ... 150 Hz, 2g

Approvals
Ec
MarkingCE Compliance
Testing environment simulations
MarkingISA-S71.04
noteG3

Montage
Mounting typeRail Mounting
Installation instructionsTaking derating into account
Installation LocationVertical or horizontal
LinkPush-in connection

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.