PHOENIX CONTACT PSR-M-EF7-XC-SAI4-PI PSR-M-EF7-XC-SAI4-PI 1337851 PHOENIX CONTACT Secure expansion module with 4 secure analog inputs, 0 V ... 10.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

PSR-M-EF7-XC-SAI4-PI 1337851 PHOENIX CONTACT Secure expansion module with 4 secure analog inputs, 0 V ... 10..

PSR-M-EF7-XC-SAI4-PI

1337851

PHOENIX CONTACT

1 Pcs.

Secure expansion module with 4 secure analog inputs, 0 V ... 10 V, 0 mA or 4 mA... 20 mA, TBUS interface, up to category 4/PL e, SIL 3, plug-in push-in terminal, TBUS connector included Safe extension module with 4 safe analog inputs, 0 V ... 10 V; 0 mA or 4 mA ... 20 mA; TBUS interface, up to Cat. 4/PL e, SIL 3, plug-in Push-in terminal block, TBUS connector included

Automation > Device for monitoring of safety-related circuits
Safety

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

A Phoenix Contact secure expansion module processes analog input signals within safety-rated automation loops, monitoring variables like pressure or temperature in hazardous zones. It integrates directly with master control architectures to maintain functional safety compliance.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Product type: Safety device
  • Application: Analog IN
  • Insulation characteristics Protection class: III
  • Times Response time: see user manual
  • Restart time: min. 5 s (Boot time)
  • Maximum power dissipation for nominal condition: 2.76 W (with max. permissible load)
  • Nominal operating mode: 100% operating factor
  • Interfaces: DIN rail TBUS for connection to the master module, supplied as standard
  • Rated surge voltage/insulation: Basic insulation 4 kV between all current paths and housing
  • Supply Designation: A1/A2
  • Rated control circuit supply voltage U S: 19.2 V DC ... 28.8 V DC
  • Rated control circuit supply voltage U S: 24 V DC -20 % / +20 % (external fuse, typically 6 A)
  • Rated control supply current I S: typ. 82 mA (without sensor supply)
  • Power consumption at U S: typ. 1.96 W (without sensor supply)
  • Inrush current: max. 14 A (Δt = 1 ms at U s )
  • Filter time: typ. 5 ms (in the event of voltage dips at U s )

More info

▲
Technical data

Product properties
Product typeSafety device
ApplicationAnalog IN
Insulation characteristics
Protection classIII
Times
Response timesee user manual
Restart timemin. 5 s (Boot time)
max. 10 s (Boot time)

Electrical properties
Maximum power dissipation for nominal condition2.76 W (with max. permissible load)
Nominal operating mode100% operating factor
InterfacesDIN rail TBUS for connection to the master module, supplied as standard
Air clearances and creepage distances
Rated insulation voltage250 V AC
Rated surge voltage/insulationBasic insulation 4 kV between all current paths and housing
Electrical isolation, 0.5 kV functional insulation between logic and analog inputs and between the analog inputs
Supply
DesignationA1/A2
Rated control circuit supply voltage US19.2 V DC ... 28.8 V DC
Rated control circuit supply voltage US24 V DC -20 % / +20 % (external fuse, typically 6 A)
Rated control supply current IStyp. 82 mA (without sensor supply)
typ. 212 mA (with sensor supply)
Power consumption at UStyp. 1.96 W (without sensor supply)
typ. 5.08 W (with sensor supply)
Inrush currentmax. 14 A (Δt = 1 ms at Us)
Filter timetyp. 5 ms (in the event of voltage dips at Us)
Protective circuitSerial protection against polarity reversal

Input data
General
Protective circuitOverload protection of the current inputs; Suppressor diode
Analog
Input nameIN S1, IN S2, IN S3, IN S4
Description of the inputSafety-oriented analog inputs, configurable as current or voltage inputs, galvanically isolated
Number of inputs4
Connection technology2-conductor, 3-conductor or 4-conductor (2-conductor sensor signal + 2-conductor sensor supply)
Note regarding the connection technologyshielded
Scanning rate2.5/5/10/16.6/20/50/60/100/200/400/800/1000/2000/4000 Hz
Current input signal0 mA ... 25 mA (Measuring range)
0 mA ... 20 mA (Configurable measuring range with diagnostics range 20.1 mA ... 23 mA)
4 mA ... 20 mA (Configurable measuring range with diagnostics range 20.1 mA ... 23 mA (upper limit), 2.5 mA ... 3.8 mA (lower limit))
Voltage input signal0 V ... 12 V (Measuring range)
0 V ... 10 V (Configurable measuring range with diagnostics range 10.05 V ... 11.5 V (upper limit), 0.1 V (lower limit))
Max. permissible currentmax. 35 mA (as current input)
Permissible voltagemax. 24 V (as current input)
max. 14 V (as voltage input)
Input resistance current input290 Ω ±25 % (incl. internal protective circuit)
Input resistance of voltage input185 kΩ ±25 %
A/D converter resolution16 bit
Resolution (current)381 nA
Resolution (voltage)152 µV
Precisiontyp. ± 2 % (as current input, relative to the measuring range final value)
max. ± 2.5 % (as current input)
typ. ± 1 % (as voltage input, relative to the measuring range final value)
max. ± 1.5 % (as voltage input)
Temperature coefficientstyp. ± 0.07 %/K
max. ± 0.07 %/K
Limit frequency (3 dB)160 Hz (RC low pass, 1st order, as current input)
4 Hz (RC low pass, as voltage input)
Frequency20 Hz (max. recommended sensor signal frequency, as current input)
2 Hz (max. recommended sensor signal frequency, as voltage input)
Permissible cable lengthmax. 100 m (per input)
Protective circuitOverload protection of the current inputs
Overload protection of the voltage inputs

Output data
Sensor supply: OUT S1/0V ...OUT S4/0V
DescriptionSensor supply voltage per analog input
Supply voltage24 V DC ±3 %
Currentmax. 30 mA (Sensor current recording per channel)
Short-circuit-proofyes
Protective circuitOverload protection Overload detection at  38 mA

Connection data
Connection technology
pluggableyes
Conductor connection
Connection methodPush-in connection
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross-section AWG24 ... 16
Stripping length10 mm

Signaling
Status display4x LED (yellow, red)
Operating voltage display1 x green LED

Dimensions
Width22.61 mm
Height107.74 mm
Depth113.6 mm

Material specifications
Housing materialPolyamide PA non-reinforced

Characteristics
Safety data
Stop category0
Safety data: EN ISO 13849
Performance level (PL)e (2-channel wiring)
d (1-channel wiring)
Safety data: IEC 61508 - High-demand for 2-channel wiring
Safety Integrity Level (SIL)3
Safety data: IEC 61508 - High-demand for 1-channel wiring
Safety Integrity Level (SIL)2
Safety data
Safety Integrity Level (SIL)2
Safety data: EN IEC 62061
Safety Integrity Level (SIL)3 (2-channel wiring)
2 (1-channel wiring)

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP20
Min. degree of protection of inst. locationIP54
Ambient temperature (operation)-10 °C ... 70 °C (observe derating)
Ambient temperature (storage/transport)-20 °C ... 85 °C
Maximum altitude≤ 2000 m (Above sea level)
Max. permissible humidity (storage/transport)95 % (non-condensing)
Max. permissible relative humidity (operation)95 % (non-condensing)
Shock10g for Δt = 16 ms (continuous shock, 1000 shocks in each space direction)
Vibration (operation)10 Hz ... 150 Hz, 2g

Approvals
CE
IdentificationCE-compliant
Environmental simulation test
IdentificationISA-S71.04
NoteG3

Mounting
Mounting typeDIN rail mounting
Assembly instructionsObserve derating
Mounting positionvertical or horizontal
Connection methodPush-in connection

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.