PSR-M-B3-XC-SDI8-SDO4-DO4-PI 1337855 PHOENIX CONTACT Configurable safety module (basic module), 8 SDI, 4 SDO..
PSR-M-B3-XC-SDI8-SDO4-DO4-PI
1337855
PHOENIX CONTACT
1 Pcs.
Automation > Device for monitoring of safety-related circuits
Safety
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Configurable safety modules such as the Phoenix Contact PSR-M-B3-XC-SDI8-SDO4-DO4-PI 1337855 PHOENIX CONTACT Configurable safety module (basic module), 8 SDI, 4 SDO.. provide programmable oversight for complex automated systems and industrial manufacturing machinery. These advanced units process multiple safety inputs and logical conditions to ensure compliance with stringent plant safety regulations. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: Safety device
- Application: Emergency stop
- Insulation characteristics Protection class: III
- Times Response time: see user manual
- Restart time: min. 5 s (Boot time)
- Maximum power dissipation for nominal condition: 9.85 W (with max. permissible load)
- Nominal operating mode: 100% operating factor
- Interfaces: DIN rail TBUS for connection to the master module, not supplied as standard
- Rated surge voltage/insulation: Basic insulation 4 kV between all current paths and housing
- Supply Designation: A1/A2
- Rated control circuit supply voltage U S: 19.2 V DC ... 28.8 V DC
- Rated control circuit supply voltage U S: 24 V DC -20 % / +20 % (provide external protection, typically 5 A)
- Rated control supply current I S: 120 mA (RMS typ. inactive for all outputs)
- Power consumption at U S: typ. 2.88 W (Outputs inactive)
- Inrush current: < 14.4 A (Δt = 0.5 ms at U s )
- Filter time: typ. 5 ms (at A1 in the event of voltage dips at U s )
More info
▲| Product type | Safety device |
| Application | Emergency stop |
| Light grid | |
| Safety door | |
| Safe shutdown | |
| Insulation characteristics | |
| Protection class | III |
| Times | |
| Response time | see user manual |
| Restart time | min. 5 s (Boot time) |
| max. 10 s (Boot time) | |
| Maximum power dissipation for nominal condition | 9.85 W (with max. permissible load) |
| Nominal operating mode | 100% operating factor |
| Interfaces | DIN rail TBUS for connection to the master module, not supplied as standard |
| Air clearances and creepage distances between the power circuits | |
| Rated insulation voltage | 250 V AC |
| Rated surge voltage/insulation | Basic insulation 4 kV between all current paths and housing |
| Supply | |
| Designation | A1/A2 |
| Rated control circuit supply voltage US | 19.2 V DC ... 28.8 V DC |
| Rated control circuit supply voltage US | 24 V DC -20 % / +20 % (provide external protection, typically 5 A) |
| Rated control supply current IS | 120 mA (RMS typ. inactive for all outputs) |
| 100 mA (without communication via network) | |
| 185 mA (Current peaks every 1.55 s with network communication) | |
| Power consumption at US | typ. 2.88 W (Outputs inactive) |
| Inrush current | < 14.4 A (Δt = 0.5 ms at Us) |
| Filter time | typ. 5 ms (at A1 in the event of voltage dips at Us) |
| Protective circuit | Serial protection against polarity reversal |
| Digital: IN1, IN2, IN3, IN4, IN5, IN6, IN7, IN8 | |
| Description of the input | Safety-related digital inputs |
| NPN | |
| Number of inputs | 8 |
| Input voltage range "0" signal | 0 V DC ... 5 V DC |
| Input voltage range "1" signal | 11 V DC ... 28.8 V DC |
| Input current range "0" signal | < 0.2 mA |
| Filter time | min. 3 ms ±2 ms (adjustable) |
| max. 250 ms ±2 ms (adjustable) | |
| min. test pulse rate ≥ 2 x set filter time, test pulse rate = 10 ms | |
| Cable length | max. 100 m (per input) |
| Max. permissible overall conductor resistance | max. 1.2 kΩ (Input and reset circuit at US) |
| Current consumption | typ. 3.7 mA (typically with US) |
| max. 4.6 mA (at a control voltage of 28.8 V DC) | |
| Digital: Digital inputs (FBK) | |
| Description of the input | configurable (as signal output or secure digital input) |
| NPN | |
| Number of inputs | 4 |
| Input voltage range "0" signal | 0 V DC ... 5 V DC |
| Input voltage range "1" signal | 11 V DC ... 28.8 V DC |
| Input current range "0" signal | < 0.2 mA |
| Filter time | 250 ms ±2 ms (Test pulse rate > 1 s) |
| Cable length | max. 100 m (per input) |
| Max. permissible overall conductor resistance | 1.2 kΩ (Input and reset circuit at US) |
| Current consumption | typ. 5.7 mA (typically with US) |
| max. 7 mA (at a control voltage of 28.8 V DC) | |
| Digital: O1, O2, O3, O4 | |
| Output description | Safety-related digital outputs |
| PNP, OSSD | |
| IEC 61131-2 type 0.25 (observe limiting continuous current) | |
| Number of outputs | 4 |
| Short-circuit protection | no |
| Leakage current | max. 500 µA |
| Cable length | max. 100 m (per output) |
| Ohmic load | min. 50 Ω (Observe limiting continuous current) |
| Max. capacitive load | max. 820 nF |
| Max. inductive load | max. 2.4 mH |
| Limiting continuous current | 400 mA (per channel) |
| 1.6 A (Total current of all safe digital outputs) | |
| Inrush current | max. 600 mA (Δt |
| Nominal output voltage | 24 V DC (Supply via A1) |
| Nominal output voltage range | 18.5 V DC ... 28.1 V DC (US- 0,7 V) |
| Switching frequency | max. 1/4 x tCycle[Hz] |
| Output voltage when switched off | < 0.3 V |
| Test pulses | < 120 µs (Test pulse width of low test pulses) |
| ≥ 650 ms (Test pulse rate for low test pulse) | |
| < 150 µs (Test pulse width, high test pulse) | |
| ≥ 1.5 s (Test pulse rate, high test pulse) | |
| Discharging circuit | Yes, internal |
| Signal: MO1, MO2, MO3, MO4 | |
| Output description | PNP, IEC 61131-2 Typ 0,1 |
| non-safety-related, configurable (as signal output or reset input) | |
| Number of outputs | 4 |
| Output voltage when switched off | max. 0.1 V |
| Voltage | 24 V DC (via A1) |
| Maximum inrush current | 1.1 A (Δt = 3 s at Us) |
| Limiting continuous current | 100 mA (per channel) |
| 400 mA (Total current of all digital signal outputs) | |
| Leakage current | max. 4.5 mA |
| Switching frequency | max. 1/4 x tCycle[Hz] |
| Short-circuit protection | Yes (self-limitation at 1.1 A) |
| Cable length | max. 100 m (per output) |
| Clock: T1, T2, T3, T4 | |
| Output description | PNP, IEC 61131-2 Typ 0,1 |
| Number of outputs | 4 |
| Voltage | 24 V DC (via A1) |
| Maximum inrush current | 1.1 A (Δt = 3 s at Us) |
| Limiting continuous current | 100 mA (per channel) |
| 400 mA (Total current of all outputs) | |
| Test pulses | ≤ 200 µs (Test pulse duration) |
| Test pulse rate = 8 x tCycle[ms] | |
| Short-circuit protection | Yes (self-limitation at 1.1 A) |
| Cable length | max. 100 m (per output) |
| Max. capacitive load | max. 470 nF |
| Max. inductive load | max. 2.4 mH |
| Discharging circuit | Yes, internal |
| Connection technology | |
| pluggable | yes |
| Conductor connection | |
| Connection method | Push-in connection |
| Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross-section AWG | 24 ... 16 |
| Stripping length | 10 mm |
| Data: Network interface | |
| Communication protocol | PROFINET |
| EtherCAT | |
| EtherNet/IP™ | |
| Modbus/TCP | |
| Connection method | RJ45 jack |
| Number of connections | 2 |
| Transmission speed | 100 Mbps (Full duplex) |
| Data: Service interface | |
| Connection method | USB type C |
| Number of connections | 1 |
| Status display | 1 x LED (green), 1 x LED (orange), 1 x LED (blue) |
| 4 x LED (green, yellow, red) | |
| 12 x LED (yellow) | |
| 2 x LED (green, red) | |
| Operating voltage display | 1 x green LED |
| Error indication | 2 x LED (red) |
| Width | 45.2 mm |
| Height | 107.74 mm |
| Depth | 113.6 mm |
| Housing material | Polyamide PA non-reinforced |
| Safety data | |
| Stop category | 0 |
| Safety data: EN ISO 13849 | |
| Performance level (PL) | e (2-channel wiring) |
| d (1-channel wiring) | |
| Safety data: IEC 61508 - High-demand for 2-channel wiring | |
| Safety Integrity Level (SIL) | 3 |
| Safety data: IEC 61508 - High-demand for 1-channel wiring | |
| Safety Integrity Level (SIL) | 2 |
| Safety data | |
| Safety Integrity Level (SIL) | 1 |
| Safety data: EN IEC 62061 | |
| Safety Integrity Level (SIL) | 3 (2-channel wiring) |
| 2 (1-channel wiring) | |
| Ambient conditions | |
| Degree of protection | IP20 |
| Min. degree of protection of inst. location | IP54 |
| Ambient temperature (operation) | -10 °C ... 70 °C (observe derating) |
| Ambient temperature (storage/transport) | -20 °C ... 85 °C |
| Maximum altitude | ≤ 2000 m (Above sea level) |
| Max. permissible humidity (storage/transport) | 95 % (non-condensing) |
| Max. permissible relative humidity (operation) | 95 % (non-condensing) |
| Shock | 10g for Δt = 16 ms (continuous shock, 1000 shocks in each space direction) |
| Vibration (operation) | 10 Hz ... 150 Hz, 2g |
| CE | |
| Identification | CE-compliant |
| Environmental simulation test | |
| Identification | ISA-S71.04 |
| Note | G3 |
| Mounting type | DIN rail mounting |
| Assembly instructions | Observe derating |
| Mounting position | vertical or horizontal |
| Connection method | Push-in connection |