View larger
PRT-1S-350/5S 2908551 PHOENIX CONTACT Type 2 surge arrester
PRT-1S-350/5S
2908551
PHOENIX CONTACT
10 Pcs.
Automation > Surge protection device for power supply systems
Trabtech (TT)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact PRT-1S-350/5S type 2 surge arrester protects electrical equipment and control systems from transient overvoltage occurrences. Surge suppression devices are installed inside switchgear enclosures to limit voltage surges to safe operating levels.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- System configuration DC (EF009926): No
- System configuration IT (EF009927): No
- System configuration TN (EF009928): No
- System configuration TN-C (EF009929): No
- System configuration TN-C-S (EF009933): No
- System configuration TN-S (EF009930): Yes
- System configuration TT (EF009931): No
- System configuration other (EF009932): No
- Nominal discharge surge current (8/20) (EF004214): 5 kA
- Max. continuous voltage AC (EF004198): 350 V
- Voltage protection level L-N (EF004236): 1.5 kV
- Short-circuit breaking capacity (Isccr) (EF012627): 1 kA
- Integrated backup fuse (EF008797): Yes
- Leakage-current free (EF016002): No
- Signalling at the device (EF004241): Optic
- Category type 2 (EF004230): Yes
More info
▲Key Commercial Data
| Orderkey | 2908551 |
|---|---|
| Packing unit | 10 pc |
| Minimum order quantity | 10 pc |
| Note | Made to Order (non-returnable) |
| Catalog page | Page 70 (C-4-2017) |
| GTIN | 4055626309026 |
| Weight per Piece (excluding packing) | 22.300 g |
| Custom tariff number | 85363010 |
| Country of origin | CN (China) |
Ambient conditions
| Degree of protection | IP20 |
|---|---|
| Ambient temperature (operation) | -40 °C ... 85 °C |
| Ambient temperature (storage/transport) | -40 °C ... 105 °C |
| Altitude | ≤ 5000 m (amsl (above mean sea level)) |
| Permissible humidity (operation) | 5 % ... 95 % |
General
| IEC test classification | II |
|---|---|
| T2 | |
| EN type | T2 |
| IEC power supply system | TN-S |
| TT | |
| Mode of protection | L-N |
| L-PE | |
| N-PE | |
| Mounting type | PCB mounting |
| Color | light grey RAL 7035 |
| Housing material | PA 6.6 |
| Degree of pollution | 2 |
| Flammability rating according to UL 94 | V-0 |
| Type | PCB onboard surge protector |
| Surge protection fault message | optical |
Protective circuit
| Nominal voltage UN | 230 V AC (TN) |
|---|---|
| 230 V AC (TT) | |
| Nominal frequency fN | 50 Hz (60 Hz) |
| Maximum continuous voltage UC | 350 V AC |
| Nominal discharge current In(8/20) µs | 5 kA |
| Short-circuit current rating ISCCR | 1 kA |
| Voltage protection level Up | ≤ 1.5 kV |
| TOV behavior at UT(L-N) | 336 V AC (5 s / withstand mode) |
| 440 V AC (120 min / withstand mode) | |
| TOV behavior at UT(N-PE) | 1200 V AC (200 ms / withstand mode) |
| Response time tA(L-N) | ≤ 25 ns |
| Response time tA(L-PE) | ≤ 100 ns |
| Response time tA(N-PE) | ≤ 100 ns |
| Max. backup fuse with branch wiring | 16 A AC (MCB B/general purpose) |
UL specifications
| SPD Type | 4CA |
|---|---|
| Maximum continuous operating voltage MCOV | 350 V AC |
| Maximum continuous operating voltage MCOV (L-N) | 350 V AC |
| Maximum continuous operating voltage MCOV (L-G) | 350 V AC |
| Maximum continuous operating voltage MCOV (N-G) | 350 V AC |
| Nom. voltage | 230 V AC |
| Mode of protection | L-N |
| N-G | |
| L-G | |
| Power distribution system | Single phase |
| Nominal frequency | 50/60 Hz |
| Measured limiting voltage MLV (L-N) | 1400 V |
| Measured limiting voltage MLV (L-G) | 1400 V |
| Measured limiting voltage MLV (N-G) | 1400 V |
| Nominal discharge current In(L-N) | 5 kA |