PHOENIX CONTACT PSM-CABLE-PROFIB/FC PSM-CABLE-PROFIB/FC 2744652 PHOENIX CONTACT Bus system cable View larger
Images are for illustrative purposes only. Please refer to data sheet for details

PSM-CABLE-PROFIB/FC 2744652 PHOENIX CONTACT Bus system cable

PSM-CABLE-PROFIB/FC

2744652

PHOENIX CONTACT

1 m.

Bus system cable By meters, Bus system cable, PROFIBUS (12 MBit/s), shielded, PVC FR VI/PVC, violet, 2-conductors (1X2XAWG22/1), color single conductors: red, green, cable length: Free input (1.0 ... 1000.0 m) By the meter, Bus system cable, PROFIBUS (12 Mbps), shielded, PVC FR VI/PVC, violet, 2-wire (1x2xAWG22/1), color single wire: red, green, cable length: Free entry (1.0 ... 1000.0 m)

Cables > Data and communication cable
Industrial Field Connectivity (IFC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Connect PROFIBUS network nodes securely with the Phoenix Contact PSM-CABLE-PROFIB/FC Bus system cable. Fieldbus data cables provide dependable high-speed communication across distributed automation hardware and industrial controllers. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Product type: Data cable by the meter
  • Sensor type: PROFIBUS
  • Number of positions: 2
  • Shielded: yes
  • Nominal voltage U N: 48 V AC
  • Transmission medium: Copper
  • Signal type/category: PROFIBUS, 12 Mbps
  • Cable length: Free entry (1.0 ... 1000.0 m)
  • Cable weight: 80 kg/km
  • UL AWM Style: 21694 (60 °C / 600 V)
  • Wiring standards/regulations: Conductor material DIN EN 13602 Cu-ETP-A...
  • Number of positions: 2
  • Shielded: yes
  • Conductor structure: 1x2xAWG22/1
  • Signal speed: 0.81 c
  • Conductor structure signal line: 1x 0.65 mm

More info

▲
Technical data

Product properties
Product typeData cable by the meter
Sensor typePROFIBUS
Number of positions2
Shieldedyes

Electrical properties
Nominal voltage UN48 V AC
60 V DC
Transmission mediumCopper

Interfaces
Signal type/categoryPROFIBUS, 12 Mbps

Cable/line
Cable lengthFree entry (1.0 ... 1000.0 m)
Cable weight80 kg/km
UL AWM Style21694 (60 °C / 600 V)
Wiring standards/regulationsConductor material DIN EN 13602 Cu-ETP-A...
Shielding material DIN EN 13602 Cu-ETP-A...-B
Number of positions2
Shieldedyes
Conductor structure1x2xAWG22/1
Signal speed0.81 c
Conductor structure signal line1x 0.65 mm
AWG signal line22
Conductor cross section2x 0.34 mm²
Wire diameter incl. insulation2.55 mm
External cable diameter8.00 mm ±0.4 mm
Outer sheath, materialPVC FR VI
External sheath, colorviolet
Conductor materialBare Cu wire
Material wire insulationPE
Single wire, colorred, green
Thickness, insulation0.95 mm
Thickness, outer sheath0.90 mm
Overall twist2 wires, twisted
Optical shield covering55 %
Insulation resistance≥ 16 GΩ*km
Loop resistance≤ 110.00 Ω/km
Cable capacityapprox. 28.5 nF/km (at 1 kHz)
≤ 1500 pF/km (asymmetrical: Conductor to ground)
Cable impedance150 Ω ±10 % (3 ... 20 MHz)
185 Ω ±10 % (31.25 ... 38.4 kHz)
270 Ω ±10 % (9.6 kHz)
Test voltage3600 V DC (3 s)
Smallest bending radius, fixed installation≥ 150 mm
Tensile strength≤ 100 N
Shield attenuation≤ 42.00 dB/km (at 16 MHz)
≤ 22.00 dB (at 4 МHz)
≤ 4.00 dB (at 38.4 kHz)
≤ 2.50 dB (at 9.6 kHz)
Flame resistanceaccording to IEC 60332-3-24 (Cat. C )
according to CMG FT4
Resistance to oilLimited resistance to mineral oils and greases
according to IEC 60811-2-1, 4 h at 70 °C
Other resistanceCold bending resistance (according to DIN VDE 0473 Part 811-1-4 (after 16 h at -40 °C))
UV resistant (CL3 SUN RES)
Ambient temperature (operation)-40 °C ... 60 °C

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.