View larger
PSM-CABLE-PROFIB/FC 2744652 PHOENIX CONTACT Bus system cable
PSM-CABLE-PROFIB/FC
2744652
PHOENIX CONTACT
1 m.
Cables > Data and communication cable
Industrial Field Connectivity (IFC)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Connect PROFIBUS network nodes securely with the Phoenix Contact PSM-CABLE-PROFIB/FC Bus system cable. Fieldbus data cables provide dependable high-speed communication across distributed automation hardware and industrial controllers. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: Data cable by the meter
- Sensor type: PROFIBUS
- Number of positions: 2
- Shielded: yes
- Nominal voltage U N: 48 V AC
- Transmission medium: Copper
- Signal type/category: PROFIBUS, 12 Mbps
- Cable length: Free entry (1.0 ... 1000.0 m)
- Cable weight: 80 kg/km
- UL AWM Style: 21694 (60 °C / 600 V)
- Wiring standards/regulations: Conductor material DIN EN 13602 Cu-ETP-A...
- Number of positions: 2
- Shielded: yes
- Conductor structure: 1x2xAWG22/1
- Signal speed: 0.81 c
- Conductor structure signal line: 1x 0.65 mm
More info
▲| Product type | Data cable by the meter |
| Sensor type | PROFIBUS |
| Number of positions | 2 |
| Shielded | yes |
| Nominal voltage UN | 48 V AC |
| 60 V DC | |
| Transmission medium | Copper |
| Signal type/category | PROFIBUS, 12 Mbps |
| Cable length | Free entry (1.0 ... 1000.0 m) |
| Cable weight | 80 kg/km |
| UL AWM Style | 21694 (60 °C / 600 V) |
| Wiring standards/regulations | Conductor material DIN EN 13602 Cu-ETP-A... |
| Shielding material DIN EN 13602 Cu-ETP-A...-B | |
| Number of positions | 2 |
| Shielded | yes |
| Conductor structure | 1x2xAWG22/1 |
| Signal speed | 0.81 c |
| Conductor structure signal line | 1x 0.65 mm |
| AWG signal line | 22 |
| Conductor cross section | 2x 0.34 mm² |
| Wire diameter incl. insulation | 2.55 mm |
| External cable diameter | 8.00 mm ±0.4 mm |
| Outer sheath, material | PVC FR VI |
| External sheath, color | violet |
| Conductor material | Bare Cu wire |
| Material wire insulation | PE |
| Single wire, color | red, green |
| Thickness, insulation | 0.95 mm |
| Thickness, outer sheath | 0.90 mm |
| Overall twist | 2 wires, twisted |
| Optical shield covering | 55 % |
| Insulation resistance | ≥ 16 GΩ*km |
| Loop resistance | ≤ 110.00 Ω/km |
| Cable capacity | approx. 28.5 nF/km (at 1 kHz) |
| ≤ 1500 pF/km (asymmetrical: Conductor to ground) | |
| Cable impedance | 150 Ω ±10 % (3 ... 20 MHz) |
| 185 Ω ±10 % (31.25 ... 38.4 kHz) | |
| 270 Ω ±10 % (9.6 kHz) | |
| Test voltage | 3600 V DC (3 s) |
| Smallest bending radius, fixed installation | ≥ 150 mm |
| Tensile strength | ≤ 100 N |
| Shield attenuation | ≤ 42.00 dB/km (at 16 MHz) |
| ≤ 22.00 dB (at 4 МHz) | |
| ≤ 4.00 dB (at 38.4 kHz) | |
| ≤ 2.50 dB (at 9.6 kHz) | |
| Flame resistance | according to IEC 60332-3-24 (Cat. C ) |
| according to CMG FT4 | |
| Resistance to oil | Limited resistance to mineral oils and greases |
| according to IEC 60811-2-1, 4 h at 70 °C | |
| Other resistance | Cold bending resistance (according to DIN VDE 0473 Part 811-1-4 (after 16 h at -40 °C)) |
| UV resistant (CL3 SUN RES) | |
| Ambient temperature (operation) | -40 °C ... 60 °C |