RIF-0-OPT-24DC/230AC/1 2905295 PHOENIX CONTACT Solid-state relay module
RIF-0-OPT-24DC/230AC/1
2905295
PHOENIX CONTACT
10 Pcs.
Automation > Optocoupler
Industrial Relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
RIF-0-OPT-24DC/230AC/1 from Phoenix Contact is a solid-state relay module configured to bridge low-voltage DC control systems with alternating current loads. They provide reliable, noiseless switching performance in compact modular housings designed for DIN rail mounting. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Input voltage (EF003840): 19.2 V
- Type of voltage (input voltage) (EF003033): DC
- Output voltage (EF003933): 24 V
- Type of output voltage (EF008222): AC
- Rated operation current Ie (EF001443): 0.75 A
- Type of digital output (EF003601): Electronic
- With LED indication (EF005950): Yes
More info
▲Key Commercial Data
| Orderkey | 2905295 |
|---|---|
| Packing unit | 10 pc |
| Catalog page | Page 337 (C-5-2017) |
| GTIN | 4046356945431 |
| Weight per Piece (excluding packing) | 24.000 g |
| Custom tariff number | 85364110 |
| Country of origin | JP (Japan) |
Note
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 60 °C |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Degree of protection | IP20 |
Input data
| Input voltage range | 19.2 V DC ... 28.8 V DC |
|---|---|
| Rated actuating voltage UC | 24 V DC |
| "0" signal switching threshold in reference to UC | < 0.4 |
| "1" signal switching threshold in reference to UC | > 0.8 |
| Typical response time | 10 ms |
| Typical turn-off time | 10 ms |
| Status display | Yellow LED |
| Type of protection | Free-wheeling diode |
| Transmission frequency | 10 Hz |
| Power dissipation for nominal condition | 0.19 W |
Output data
| Output voltage range | 24 V AC ... 253 V AC (50/60 Hz) |
|---|---|
| Limiting continuous current | 0.75 A (see derating curve) |
| Maximum inrush current | 30 A (10 ms) |
| Min. load current | 10 mA |
| Leakage current | 1 mA (in off state) |
| Surge current | 30 A AC (tp = 20 ms, at 25°C) |
| Max. load value | 4.5 A2s (tp = 10 ms, at 25 °C) |
| Surge voltage protection | > 275 V |
| Voltage drop at max. limiting continuous current | < 1 V |
| Output circuit | 2-wire, zero voltage switch |
| Type of protection | RCV circuit |
Connection data 1
| Connection name | Input side |
|---|---|
| Connection method | Push-in connection |
| Stripping length | 8 mm |
| Conductor cross section solid | 0.14 mm² ... 1.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 1.5 mm² |
| 0.14 mm² ... 1.5 mm² (Ferrule with plastic sleeve) | |
| Conductor cross section AWG | 24 ... 16 |
Connection data 2
| Connection name | Output side |
|---|---|
| Connection method | Push-in connection |
| Stripping length | 8 mm |
| Conductor cross section solid | 0.14 mm² ... 1.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 1.5 mm² |
| 0.14 mm² ... 1.5 mm² (Ferrule with plastic sleeve) | |
| Conductor cross section AWG | 24 ... 16 |
General
| Test voltage input/output | 2.5 kVrms(50 Hz, 1 min.) |
|---|---|
| Mounting position | any |
| Assembly instructions | In rows with zero spacing |
| Operating mode | 100% operating factor |
| Flammability rating according to UL 94 | V2 |
| Designation | Air clearances and creepage distances between the power circuits |
| Standards/regulations | DIN EN 50178 |
| Degree of pollution | 2 |
| Overvoltage category | III |
Standards and Regulations
| Designation | Air clearances and creepage distances between the power circuits |
|---|---|
| Standards/regulations | DIN EN 50178 |
| Rated insulation voltage | 260 V AC |
| Rated surge voltage | 4 kV |
| Insulation | Basic insulation |
| Degree of pollution | 2 |
| Overvoltage category | III |
| Flammability rating according to UL 94 | V2 |
Environmental Product Compliance
| China RoHS | Environmentally Friendly Use Period = 50 |
|---|---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |