View larger
PP-RJ-SC-F 2703021 PHOENIX CONTACT Patch panels
PP-RJ-SC-F
2703021
PHOENIX CONTACT
1 Pcs.
Automation > Patch panel copper (twisted pair)
Safety
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Designed for industrial automation control cabinets, the Phoenix Contact PP-RJ-SC-F patch panel (2703021) provides a secure, streamlined interface for terminating and organizing Ethernet communication pathways. It ensures dependable signal transfer in high-vibration or restricted-space environments. Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Number of buses/couplings (EF004395): 1
- Suitable for number of connectors (EF001579): 1
- Screened (EF000881): Yes
- Category (EF001619): 5
- Number of height units (EF003561): 2
- Height (EF000040): 101.3 mm
- Width (EF000008): 23.8 mm
- Depth (EF000049): 86 mm
More info
▲Key Commercial Data
| Orderkey | 2703021 |
|---|---|
| Packing unit | 1 pc |
| Note | Made to Order (non-returnable) |
| GTIN | 4055626463339 |
| Weight per Piece (excluding packing) | 124.200 g |
| Custom tariff number | 85366990 |
| Country of origin | DE (Germany) |
Ambient conditions
| Ambient temperature (operation) | -40 °C ... 75 °C |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Permissible humidity (operation) | 10 % ... 95 % (non-condensing) |
| Altitude | 5000 m (For restrictions see manufacturer's declaration) |
| 2000 m (ATEX approval) | |
| Degree of protection | IP20 (Manufacturer's declaration) |
General
| Electrical isolation | FE // Ethernet |
|---|---|
| Standards/regulations | DIN EN 61643-21 |
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
| Net weight | 124.2 g |
| Housing material | Plastic |
| Color | gray |
| MTTF | 3268 Years (SN 29500 standard, temperature 25 °C, operating cycle 21 % (5 days a week, 8 hours a day)) |
| 1238 Years (SN 29500 standard, temperature 40 °C, operating cycle 34.25 % (5 days a week, 12 hours a day)) | |
| 468 Years (SN 29500 standard, temperature 40 °C, operating cycle 100 % (7 days a week, 24 hours a day)) | |
| Degree of pollution | 2 |
| Overvoltage category | II |
| Conformance | CE-compliant |
| ATEX | II 3 G Ex nA nC IIC T4 Gc X (Please follow the special installation instructions in the documentation!) |
| UL, USA | UL 60079-0 Ed. 6 / UL 60079-15 Ed. 4 |
| UL, USA/Canada | Class I, Zone 2, AEx nA IIC T4, Ex nA IIC Gc X T4 |
| Class I, Div. 2, Groups A, B, C, D | |
| UL, Canada | CSA 22.2 No. 60079-0 Ed. 3 / CSA 22.2 No. 60079-15:16 |
Power supply
| Supply voltage range | 36 V DC ... 52 V DC 10 % (via PoE) |
|---|---|
| 42 V DC ... 57 V DC (With UL approval) |
Serial interface
| Interface 1 | Ethernet interface, 10/100/1000Base-T(X) according to IEEE 802.3u |
|---|---|
| Connection method | Screw terminal block |
| Transmission length | 100 m (including patch cables) |
| Conductor cross section solid min. | 0.14 mm² |
| Conductor cross section solid max. | 1.5 mm² |
| Conductor cross section flexible min. | 0.14 mm² |
| Conductor cross section flexible max. | 1.5 mm² |
| Conductor cross section AWG min. | 28 |
| Conductor cross section AWG max. | 16 |
| Torque | 0.22 Nm ... 0.25 Nm |
| Stripping length | 5 mm |
| Pin assignment | 1:1 |
| Serial transmission speed | 10/100/1000 Mbps |
| Maximum output current | 725 mA (PoE) |
| Current carrying capacity | ≤ 1.5 A (≤ 60 W (PoE+)) |
| Maximum output power | 60 W |
| Interface 2 | Ethernet interface, 10/100/1000Base-T(X) according to IEEE 802.3u |
| Connection method | RJ45 CAT5e |
Function
| Designation | Shield current monitoring |
|---|---|
| Switch-on threshold | ≥ 30 mA |
| Local diagnostics | Yellow LED |
| Precision | ± 5 % |
| Response time | 3 s |
| Continuous shield current | ≤ 1.5 A |
| Power consumption | 270 mW (Shield current monitoring) |
| Impedance | ≤ 1 Ω |
| Voltage | ≤ 10 V |
Standards and Regulations
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
|---|---|
| Type of test | Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 |
| Test result | 10 Hz ... 57 Hz, amplitude ±3.5 mm, 57 Hz ... 150 Hz, 5g |
| Type of test | Shock in acc. with EN 60068-2-27/IEC 60068-2-27 |
| Test result | 25g for 11 ms, three shocks in each direction |
| Standards/regulations | EN 61000-4-2 |
| Contact discharge | ± 6 kV (Test Level 3) |
| Indirect discharge | ± 6 kV |
| Standards/regulations | EN 61000-4-3 |
| Frequency range | 80 MHz ... 3 GHz (Test Level 3) |
| Standards/regulations | EN 61000-4-4 |
| Comments | Criterion B |
| Standards/regulations | EN 61000-4-5 |
| Signal | ± 1 kV (Data line, asymmetrical) |
| Standards/regulations | EN 61000-6-4 |
| EN 61000-4-6 | |
| Frequency range | 0.15 MHz ... 80 MHz |
| Standards/regulations | DIN EN 61643-21 |
| Rated insulation voltage | 85 V DC |
| IEC test classification | C2 |
| Conformance | CE-compliant |
| ATEX | II 3 G Ex nA nC IIC T4 Gc X |
| UL, USA | UL 60079-0 Ed. 6 / UL 60079-15 Ed. 4 |
| UL, USA/Canada | Class I, Zone 2, AEx nA IIC T4, Ex nA IIC Gc X T4 |
| Class I, Div. 2, Groups A, B, C, D | |
| UL, Canada | CSA 22.2 No. 60079-0 Ed. 3 / CSA 22.2 No. 60079-15:16 |
| Noxious gas test | ISA-S71.04-1985 G3 Harsh Group A |
Environmental Product Compliance
| China RoHS | Environmentally Friendly Use Period = 50 |
|---|---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |