View larger
SACB-4/T-L-8FUSE DIAG CT AXL 1411048 PHOENIX CONTACT Power distributor
SACB-4/T-L-8FUSE DIAG CT AXL
1411048
PHOENIX CONTACT
1 Pcs.
Cables > Passive sensor-actuator interface (without cable)
QUICKON Installation System (QPD)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A Phoenix Contact power distributor, part number SACB-4/T-L-8FUSE DIAG CT AXL, functions as an essential electrical node designed to distribute supply voltage to multiple branch circuits while protecting connected loads from overcurrent faults. Power distribution modules of this type help maintain safe, structured power distribution across demanding industrial automation systems. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Cable outer diameter for cable gland (EF007302): 9 mm
- Number of sensor-/actuator-slots (EF006939): 4
- Number of channels per connector slot (EF006885): 1
- Type of branches for sensor-/actuator cables (EF006972): M12
- Number of poles sensor/actuator slots (EF007402): 4
- Operating voltage (EF003983): 24 V
- Max. current carrying capacity per I/O signal (EF004037): 70 A
- Max. total current (EF004039): 70 A
- With LED indication (EF005950): Yes
- With potential separation (EF003272): No
- Connection for NPN-sensors (EF006817): Yes
- Operating temperature (EF002393): -25 °C
- Degree of protection (IP) (EF005474): IP66
- Width (EF000008): 60 mm
- Height (EF000040): 52 mm
More info
▲Key Commercial Data
| Orderkey | 1411048 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 303 (C-2-2017) |
| GTIN | 4046356920254 |
| Weight per Piece (excluding packing) | 552.880 g |
| Custom tariff number | 85444290 |
| Country of origin | DE (Germany) |
General
| Rated voltage | 24 V DC |
|---|---|
| Max. operating voltage Umax | 30.5 V DC |
| Current carrying capacity per I/O signal | 10 A (M12 diagnostic socket for each channel max. 50 mA) |
| Current carrying capacity per slot | 2x 9.25 A (at 40 °C) |
| Total rated current | 70 A (at 40°C, observe the distribution of the current paths under load) |
| Protective circuit | Overload protection for the outputs Fuse in header |
| Number of positions | 4 |
| Number of slots | 4 |
| Flammability rating according to UL 94 | V0 |
| Sensor/actuator connection system | M12-SPEEDCON-socket |
Ambient conditions
| Degree of protection | IP66 |
|---|---|
| IP67 | |
| Ambient temperature (operation) | -25 °C ... 60 °C |
| Ambient temperature (storage/transport) | -25 °C ... 80 °C |
Local diagnostics function
| Local diagnostics | Supply voltage per module Green LED |
|---|---|
| Status display I/O Yellow LED |
Master cable data/connection data
| Connection method | Plug-in master cable connection |
|---|---|
| Conductor cross section min. (energy) | 2.5 mm² |
| Conductor cross section max. (energy) | 6 mm² |
| Conductor cross section AWG min. (energy) | 14 |
| Conductor cross section AWG max. (energy) | 10 |
| External cable diameter min. | 9 mm |
| External cable diameter max. | 15.5 mm |
| Tightening torque, cover screw | 0.6 Nm |
| Tightening torque, union nut | 5 Nm |
| Tightening torque slot sensor/actuator cable | 0.4 Nm |
Insulation material
| Housing material | PBT |
|---|---|
| Material of the moulding mass | PUR |
| Contact material | Cu alloy |
| Contact surface material | pre-nickel plated, gold-plated |
| Contact carrier material | PA |
| Material of contact, master cable side | CU alloy |
| Material of contact surface, master cable side | Silver-plated |
| Material of the contact carrier on the master cable side | PC |
| Material of threaded sleeve | Zinc die-cast |
| Material of threaded sleeve surface | Nickel-plated |
| Sealing material | Viton (M12 socket) |
| NBR (Master cable side) |
Standards and Regulations
| Standard designation | M12 connector |
|---|---|
| Standards/regulations | IEC 61076-2-111 |
| Standard designation | Shock, vibration |
| Standards/regulations | EN 60068-2-6 |
| EN 60068-2-27 | |
| EN 60068-2-64 | |
| Flammability rating according to UL 94 | V0 |
Environmental Product Compliance
| REACh SVHC | Lead 7439-92-1 |
|---|---|
| China RoHS | Environmentally Friendly Use Period = 50 |
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |