View larger
FTRVB 8-PV /BK 3270209 PHOENIX CONTACT Potential distributors
FTRVB 8-PV /BK
3270209
PHOENIX CONTACT
10 Pcs.
Automation > Feed-through terminal block
Enclosures connectivity
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact FTRVB 8-PV /BK Potential distributors offer systematic voltage distribution across multi-tier setups within industrial automation environments. Such components organize complex power supply architectures, ensuring that electrical inputs are accurately shared among connected control devices.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Orderkey: 3270209
- Packing unit: 10 pc
- Minimum order quantity: 10 pc
- Note: Made to Order (non-returnable)
- Catalog page: Page 50 (C-1-2017)
- GTIN: 4055626118703
- Weight per Piece (excluding packing): 52.210 g
- Custom tariff number: 85369010
- Country of origin: PL (Poland)
- Number of positions: 2
- Number of levels: 8
- Number of connections: 32
- Potentials: 1
- Nominal cross section: 1.5 mm²
- Color: gray
- Color of connection elements: black
More info
▲Key Commercial Data
| Orderkey | 3270209 |
|---|---|
| Packing unit | 10 pc |
| Minimum order quantity | 10 pc |
| Note | Made to Order (non-returnable) |
| Catalog page | Page 50 (C-1-2017) |
| GTIN | 4055626118703 |
| Weight per Piece (excluding packing) | 52.210 g |
| Custom tariff number | 85369010 |
| Country of origin | PL (Poland) |
General
| Number of positions | 2 |
|---|---|
| Number of levels | 8 |
| Number of connections | 32 |
| Potentials | 1 |
| Nominal cross section | 1.5 mm² |
| Color | gray |
| Color of connection elements | black |
| Insulating material | PA |
| Flammability rating according to UL 94 | V0 |
| Rated surge voltage | 4 kV |
| Overvoltage category | III |
| Insulating material group | I |
| Maximum power dissipation for nominal condition | 0.56 W (the value is multiplied when connecting multiple levels) |
| Maximum load current | 24 A (per chamber with 2.5 mm² conductor cross section) |
| Maximum total current | 37 A (per potential distributor) |
| Nominal current IN | 17.5 A (with 1.5 mm² conductor cross section) |
| Nominal voltage UN | 250 V |
| Open side panel | Yes |
| Relative insulation material temperature index (Elec., UL 746 B) | 130 °C |
| Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) | 125 °C |
| Static insulating material application in cold | -60 °C |
| Behavior in fire for rail vehicles (DIN 5510-2) | Test passed |
| Flame test method (DIN EN 60695-11-10) | V0 |
| Oxygen index (DIN EN ISO 4589-2) | >32 % |
| NF F16-101, NF F10-102 Class I | 2 |
| NF F16-101, NF F10-102 Class F | 2 |
| Surface flammability NFPA 130 (ASTM E 162) | passed |
| Specific optical density of smoke NFPA 130 (ASTM E 662) | passed |
| Smoke gas toxicity NFPA 130 (SMP 800C) | passed |
| Calorimetric heat release NFPA 130 (ASTM E 1354) | 27,5 MJ/kg |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 |
Connection data
| Connection method | Push-in connection |
|---|---|
| Connection in acc. with standard | IEC 60947-7-1 |
| Conductor cross section solid min. | 0.14 mm² |
| Conductor cross section solid max. | 2.5 mm² |
| Conductor cross section AWG min. | 26 |
| Conductor cross section AWG max. | 14 |
| Conductor cross section flexible min. | 0.14 mm² |
| Conductor cross section flexible max. | 1.5 mm² |
| Min. AWG conductor cross section, flexible | 26 |
| Max. AWG conductor cross section, flexible | 14 |
| Conductor cross section flexible, with ferrule without plastic sleeve min. | 0.14 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve max. | 1.5 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve min. | 0.14 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve max. | 1.5 mm² |
| Stripping length | 8 mm ... 10 mm |
Standards and Regulations
| Connection in acc. with standard | IEC 60947-7-1 |
|---|---|
| Flammability rating according to UL 94 | V0 |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 |
Environmental Product Compliance
| China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
|---|---|
| No hazardous substances above threshold values |