View larger
PT 2X2-FF-ST 2800755 PHOENIX CONTACT Surge protection plug
PT 2X2-FF-ST
2800755
PHOENIX CONTACT
1 Pcs.
Automation > Surge protection device for data networks/MCR-technology
Trabtech (TT)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Prevent electrical damage to delicate IT hardware with the Phoenix Contact PT 2X2-FF-ST surge protection plug. Pluggable surge arresters are implemented in communication pathways to divert dangerous transient voltages safely to ground. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: Surge protection for information technology
- Product family: PLUGTRAB PT
- IEC test classification: C1
- VDE requirement class: C1
- Type: Male
- Number of positions: 5
- Wire pairs per module: 2
- Data management status Article revision: 09
- Insulation characteristics Overvoltage category: III
- Pollution degree: 2
- Nominal voltage U N: 32 V DC
- Connection method: Screw connection (in connection with the base element)
- Width: 17.7 mm
- Height: 45 mm
- Depth: 52 mm
- Horizontal pitch: 1 Div.
More info
▲| Product type | Surge protection for information technology |
| Product family | PLUGTRAB PT |
| IEC test classification | C1 |
| C2 | |
| C3 | |
| D1 | |
| VDE requirement class | C1 |
| C2 | |
| C3 | |
| D1 | |
| Type | Male |
| Number of positions | 5 |
| Surge protection fault message | none |
| Wire pairs per module | 2 |
| Data management status | |
| Article revision | 09 |
| Insulation characteristics | |
| Overvoltage category | III |
| Pollution degree | 2 |
| Nominal voltage UN | 32 V DC |
| Connection method | Screw connection (in connection with the base element) |
| Dimensional drawing | |
| Width | 17.7 mm |
| Height | 45 mm |
| Depth | 52 mm |
| Horizontal pitch | 1 Div. |
| Complete module width | 17.7 mm |
| Complete module height | 90 mm |
| Complete module depth | 65.5 mm |
| Color | black (RAL 9005) |
| black (RAL 9005) | |
| Flammability rating according to UL 94 | V0 |
| Housing material | PA |
| Mechanical data | |
| Open side panel | No |
| Direction of action | Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground |
| Maximum continuous voltage UC | 36 V DC |
| Rated current | 1.6 A |
| Operating effective current ICat UC | ≤ 5 µA |
| Residual current IPE | ≤ 5 µA (with PT 4-BE) |
| Nominal discharge current In(8/20) µs (line-line) | 100 A |
| Nominal discharge current In(8/20) µs (line-ground) | 10 kA |
| Pulse discharge current Iimp(10/350) µs | 1 kA |
| Max. discharge current Imax(8/20) µs maximum (line-line) | 100 A |
| Max. discharge current Imax(8/20) µs maximum (line-earth) | 10 kA |
| Nominal pulse current Ian (10/1000) µs (line-line) | 23 A |
| Output voltage limitation at 1 kV/µs (line-line) spike | ≤ 75 V |
| Output voltage limitation at 1 kV/µs (line-earth) spike | ≤ 1.3 kV (with PT 4-BE) |
| Output voltage limitation at 1 kV/µs (line-line) static | ≤ 75 V |
| Voltage protection level Up(line-line) | ≤ 75 V (C3 - 25 A) |
| Voltage protection level Up(line-earth) | ≤ 1.3 kV (C1 - 1.5 kV) |
| ≤ 1.3 kV (C2 - 9 kV) | |
| ≤ 1.3 kV (D1 - 500 A) | |
| Response time tA(line-line) | ≤ 1 ns |
| Response time tA(line-earth) | ≤ 100 ns |
| Resistance per path | ≤ 1 Ω |
| Surge protection fault message | none |
| Impulse durability (line-line) | C3 - 25 A |
| Impulse durability (line-earth) | C1 - 1 kV / 500 A |
| C2 - 10 kV / 5 kA | |
| D1 - 500 A |
| Ambient conditions | |
| Degree of protection | IP20 |
| Ambient temperature (operation) | -40 °C ... 85 °C |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Altitude | ≤ 2000 m (amsl) |
| VDE requirement class | C1 |
| C2 | |
| C3 | |
| D1 | |
| Air clearances and creepage distances | |
| Standards/regulations | DIN VDE 0110-1 / IEC 60664-1 |
| Standards/specifications | EN 61643-21/A1 |
| Note | 2009 |
| Mounting type | on base element |