View larger
SACCBP-M12MSB-5CON-M16/1,0-900 1534517 PHOENIX CONTACT Bus system flat-type plug
SACCBP-M12MSB-5CON-M16/1,0-900
1534517
PHOENIX CONTACT
1 Pcs.
Cables > Circular connector, mounting (with cable)
Field Device Connectors (FDC)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Built as an SACCBP-M12MSB-5CON-M16/1,0-900 bus system flat-type plug by Phoenix Contact, this hardware component secures reliable data links in factory floor networks. Flat-type plugs are commonly mounted onto machine housings or junction boxes to offer robust, sealed connection interfaces for fieldbus applications.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Number of data contacts (EF012232): 0
- Number of power contacts (EF012216): 0
- Number of control contacts (EF012217): 5
- Type of housing (EF006980): Straight
- Rated current In (EF008250): 4 A
- Ambient temperature (EF002386): -25 °C
- Rated voltage (EF000228): 48 V
- Over voltage category (EF006785): II
- Pollution degree (EF006786): 3
- Material of contact surface (EF004020): Nickel
- Housing material (EF001596): Plastic
- With protective conductor (EF007468): No
- Degree of protection (IP), mounted (EF007466): IP67
- Min. number of insertion cycles (EF012212): 100
- Screened (EF000881): Yes
- With status indication (EF001602): No
More info
▲Key Commercial Data
| Orderkey | 1534517 |
|---|---|
| Packing unit | 1 pc |
| Note | Made to Order (non-returnable) |
| Catalog page | Page 425 (C-2-2017) |
| GTIN | 4046356026680 |
| Weight per Piece (excluding packing) | 94.700 g |
| Custom tariff number | 85444290 |
| Country of origin | DE (Germany) |
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 85 °C |
|---|---|
| -40 °C ... 85 °C (without mechanical actuation) | |
| Degree of protection | IP67 |
General
| Note | The electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration. |
|---|---|
| Rated current at 40°C | 4 A |
| Rated voltage | 60 V |
| Rated surge voltage | 1.5 kV |
| Number of positions | 5 |
| Insulation resistance | ≥ 100 MΩ (M12 connector) |
| Coding | B - inverse |
| Standards/regulations | M12 connector IEC 61076-2-101 |
| Status display | No |
| Overvoltage category | II |
| Degree of pollution | 3 |
| Test voltage | 2500 V |
| Insertion/withdrawal cycles | > 100 |
| Torque | 2 Nm ... 3 Nm (Installation-side) |
Material
| Flammability rating according to UL 94 | V0 |
|---|---|
| Contact material | CuZn |
| Contact surface material | Ni/Au |
| Contact carrier material | PA 6.6 |
| Material, knurls | Zinc die-cast, nickel-plated |
| Sealing material | FKM |
Standards and Regulations
| Standard designation | M12 connector |
|---|---|
| Standards/regulations | IEC 61076-2-101 |
| Flammability rating according to UL 94 | V0 |
Cable
| Cable type | INTERBUS |
|---|---|
| Cable type (abbreviation) | 900 |
| Signal type/category | INTERBUS |
| Cable structure | 3 x 2 x 0.22 mm² |
| Conductor cross section | 3x 2x 0.22 mm² |
| AWG signal line | 24 |
| Conductor structure signal line | 32x 0.10 mm |
| Wire colors | Green-yellow, white-brown, gray-pink |
| Twisted pairs | 2 cores to the pair |
| Overall twist | 3 pairs to the core |
| Shielding | Braided copper wires |
| External sheath, color | may green RAL 6017 |
| External cable diameter D | 8 mm |
| Minimum bending radius, fixed installation | 7.5 x D |
| Minimum bending radius, flexible installation | 15 x D |
| Number of bending cycles | 5000000 |
| Bending radius | 120 mm |
| Traversing path | 10 m |
| Traversing rate | 1.6 m/s |
| Acceleration | 3.2 m/s² |
| Cable weight | 70 kg/km |
| Outer sheath, material | PUR |
| Material conductor insulation | PE |
| Conductor material | Bare Cu litz wires |
| Insulation resistance | ≥ 5 GΩ*km |
| Loop resistance | ≤ 159.80 Ω/km |
| Cable capacity | ≤ 60 nF/km (At 800 Hz) |
| Wave impedance | 120 Ω ±20 % (at 64 kHz) |
| 100 Ω ±15 % (with 1 MHz) | |
| Near end crosstalk attenuation (NEXT) | ≥ 61 dB (at 772 kHz) |
| ≥ 59 dB (with 1 MHz) | |
| ≥ 55 dB (at 2 МHz) | |
| ≥ 50 dB (at 4 МHz) | |
| ≥ 46 dB (at 8 МHz) | |
| ≥ 44 dB (at 10 MHz) | |
| ≥ 41 dB (at 16 MHz) | |
| ≥ 40 dB (at 20 МHz) | |
| Attenuation | ≤ 15 dB/km (at 256 kHz) |
| ≤ 24 dB/km (at 772 kHz) | |
| ≤ 27 dB/km (with 1 MHz) | |
| ≤ 52 dB/km (at 4 МHz) | |
| ≤ 84 dB/km (at 10 MHz) | |
| ≤ 112 dB/km (at 16 MHz) | |
| ≤ 119 dB/km (at 20 МHz) | |
| Signal speed | 0.66 c |
| Coupling resistance | < 250.00 mΩ/m (at 30 MHz) |
| Nominal voltage, cable | 250 V (Peak value, not for high-power applications) |
| Test voltage Core/Core | 1500 Vrms |
| Test voltage Core/Shield | 1000 Vrms |
| Flame resistance | according to VDE 0472, Part 4, test type B |
| according to IEC 60332-1 | |
| Ambient temperature (operation) | -40 °C ... 80 °C (cable, fixed installation) |
| -30 °C ... 70 °C (cable, flexible installation) |
Environmental Product Compliance
| REACh SVHC | Lead 7439-92-1 |
|---|---|
| China RoHS | Environmentally Friendly Use Period = 50 |
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |