View larger
SACC-DSI-M 8MS-6CON-M 8/0,5 1453494 PHOENIX CONTACT Flush-type connector
SACC-DSI-M 8MS-6CON-M 8/0,5
1453494
PHOENIX CONTACT
1 Pcs.
Cables > Circular connector, mounting (with cable)
Field Device Connectors (FDC)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact part SACC-DSI-M 8MS-6CON-M 8/0,5 is a flush-type connector built for compact sensor and signal connections in automated machinery. Miniature circular connectors enable high-density wiring configurations within restricted panel spaces. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Mounting type: Rear mounting M8 x 1 With flat nut
- Assembly note: With flat nut
- Product type: Circular connectors (device side)
- Number of positions: 6
- No. of cable outlets: 1
- Shielded: no
- Coding: A
- Thread type: M8
- Data management status Article revision: 02
- Insulation characteristics Overvoltage category: II
- Degree of pollution: 3
- Flammability rating according to UL 94: HB
- Seal material: FKM
- Contact material: Cu alloy
- Contact surface material: Au
- Contact carrier material: PUR/PA 6.6
More info
▲| Mounting type | Rear mounting M8 x 1 With flat nut |
| Assembly note | With flat nut |
| Product type | Circular connectors (device side) |
| Number of positions | 6 |
| No. of cable outlets | 1 |
| Shielded | no |
| Coding | A |
| Thread type | M8 |
| Data management status | |
| Article revision | 02 |
| Insulation characteristics | |
| Overvoltage category | II |
| Degree of pollution | 3 |
| Flammability rating according to UL 94 | HB |
| Seal material | FKM |
| Contact material | Cu alloy |
| Contact surface material | Au |
| Contact carrier material | PUR/PA 6.6 |
| Material for screw connection | Brass, nickel-plated |
| Conductor material | Tin-plated Cu litz wires |
| Rated surge voltage | 0.8 kV |
| Contact resistance | ≤ 3 mΩ |
| Insulation resistance | ≥ 100 MΩ |
| Nominal voltage UN | 30 V AC |
| 30 V DC | |
| Nominal current IN | 1.5 A |
| Max. conductor resistance | 80 Ω/km |
| Conductor connection | |
| Connection method | Individual wires |
| Contact connection type | Pin |
| Conductor cross section | 0.14 mm² |
| Tightening torque | 1 Nm ... 1.5 Nm (Installation-side) |
| Connection 1 | |
| Head design | Pin |
| Head cable outlet | straight |
| Head thread type | M8 |
| Cable length | 0.5 m |
| Cable type | PVC litz wire |
| Wire diameter incl. insulation | 1.3 mm ±0.1 mm |
| Single wire, color | black, brown,blue, white, gray, pink |
| Cable cross section | 0.14 mm² |
| Conductor material | Tin-plated Cu litz wires |
| Conductor structure signal line | 7x 0.16 mm |
| AWG signal line | 24 |
| Material wire insulation | PVC / UL |
| Thickness, insulation | 0.38 mm |
| Nominal voltage, cable | 300 V |
| Test voltage, cable | 2000 V AC |
| Cable resistance | ≥ 80 Ω/km |
| Cable insulation resistance | ≥ 20 MΩ*km |
| Ambient temperature (operation) | -40 °C ... 105 °C (cable, fixed installation) |
| -10 °C ... 105 °C (Cable, flexible installation) |
| Ambient conditions | |
| Degree of protection | IP67 |
| IP67 | |
| Ambient temperature (operation) | -25 °C ... 85 °C (Plug) |
| -40 °C ... 105 °C (cable, fixed installation) | |
| -10 °C ... 105 °C (Cable, flexible installation) | |
| M8 | |
| Standard designation | M8 connector |
| Standards/specifications | IEC 61076-2-104 |