A miniature solid-state relay, the Phoenix Contact OPT-24DC/ 24DC/ 2 is designed for high-frequency switching operations in control cabinets. These compact electronic switches provide galvanic isolation between input and output circuits, ensuring reliable signal transmission in automated machinery without moving contacts.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Input voltage (EF003840): 19.2 V
- Type of voltage (input voltage) (EF003033): DC
- Output voltage (EF003933): 3 V
- Type of output voltage (EF008222): DC
- Rated operation current Ie (EF001443): 3 A
- Type of digital output (EF003601): Electronic
- With LED indication (EF005950): No
More info
▲Key Commercial Data
| Orderkey | 2966595 |
|---|---|
| Packing unit | 10 pc |
| Minimum order quantity | 10 pc |
| Catalog page | Page 300 (C-5-2017) |
| GTIN | 4017918130947 |
| Weight per Piece (excluding packing) | 5.200 g |
| Custom tariff number | 85364190 |
| Country of origin | HU (Hungary) |
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 60 °C |
|---|---|
| Ambient temperature (storage/transport) | -25 °C ... 70 °C |
Input data
| Nominal input voltage UN | 24 V DC |
|---|---|
| Input voltage range in reference to UN | 0.8 ... 1.2 |
| Input voltage range | 19.2 V DC ... 28.8 V DC |
| Switching threshold "0" signal, voltage | ≤ 10 V |
| Switching threshold "1" signal voltage | ≥ 16 V |
| Typical input current at UN | 7 mA |
| Typical response time | 20 µs (at UN) |
| Typical turn-off time | 300 µs (at UN) |
| Transmission frequency | 300 Hz |
| Power dissipation for nominal condition | 0.17 W |
Output data
| Output voltage range | 3 V DC ... 33 V DC |
|---|---|
| Limiting continuous current | 3 A (see derating curve) |
| Maximum inrush current | 15 A (10 ms) |
| Voltage drop at max. limiting continuous current | ≤ 150 mV |
| Output circuit | 2-wire, floating |
| Type of protection | Reverse polarity protection |
| Surge protection |
General
| Test voltage input/output | 2.5 kV (50 Hz, 1 min.) |
|---|---|
| Mounting position | any |
| Assembly instructions | In rows with zero spacing |
| Operating mode | 100% operating factor |
| Degree of protection | RT III (wash-proof) |
| Designation | Standards/regulations |
| Standards/regulations | IEC 60664 |
| EN 50178 | |
| Degree of pollution | 2 |
| Overvoltage category | III |
Standards and Regulations
| Connection in acc. with standard | CUL |
|---|---|
| Designation | Standards/regulations |
| Standards/regulations | IEC 60664 |
| EN 50178 | |
| Insulation | Basic insulation |
| Degree of pollution | 2 |
| Overvoltage category | III |
Environmental Product Compliance
| China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
|---|---|
| No hazardous substances above threshold values |