View larger
REL-IR2/L- 24AC/2X21 2903666 PHOENIX CONTACT Single relay
REL-IR2/L-24AC/2X21
2903666
PHOENIX CONTACT
10 Pcs.
Automation > Switching relay
Industrial Relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact REL-IR2/L-24AC/2X21 is a single relay unit designed for industrial signal processing and circuit isolation within electrical distribution systems. Engineers deploy these modular components to manage control logic switching and protect sensitive controllers from voltage spikes originating in field devices. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: Single relay
- Operating mode: 100% operating factor
- Mechanical service life: approx. 2x 10 7 cycles
- Data management status Date of last data management: 02.05.2024
- Article revision: 02
- Insulation characteristics Insulation: Basic insulation
- Overvoltage category: III
- Pollution degree: 3 (Rated voltage of 230 V)
- Service life electrical: see diagram
- Maximum power dissipation for nominal condition: 1.58 W
- Test voltage (Winding/contact): 2.5 kV rms (50 Hz, 1 min., winding/contact)
- Test voltage (Contact/contact): 2.5 kV rms (50 Hz, 1 min., contact/contact)
- Test voltage (Changeover contact/changeover contact): 2.5 kV rms (50 Hz, 1 min., changeover contact/changeover contact)
- Rated insulation voltage: 250 V AC
- Rated surge voltage: 4 kV
- Coil side Nominal input voltage U N: 24 V AC
More info
▲| Product type | Single relay |
| Operating mode | 100% operating factor |
| Mechanical service life | approx. 2x 107cycles |
| Data management status | |
| Date of last data management | 02.05.2024 |
| Article revision | 02 |
| Insulation characteristics | |
| Insulation | Basic insulation |
| Overvoltage category | III |
| Pollution degree | 3 (Rated voltage of 230 V) |
| 2 (Rated voltage of 400 V) | |
| Service life electrical | see diagram |
| Maximum power dissipation for nominal condition | 1.58 W |
| Test voltage (Winding/contact) | 2.5 kVrms(50 Hz, 1 min., winding/contact) |
| Test voltage (Contact/contact) | 2.5 kVrms(50 Hz, 1 min., contact/contact) |
| Test voltage (Changeover contact/changeover contact) | 2.5 kVrms(50 Hz, 1 min., changeover contact/changeover contact) |
| Rated insulation voltage | 250 V AC |
| Rated surge voltage | 4 kV |
| Coil side | |
| Nominal input voltage UN | 24 V AC |
| Input voltage range | 18.7 V AC ... 33.1 V AC |
| Input voltage range in reference to UN | see diagram |
| Mains frequency | 50/60 Hz |
| Drive and function | monostable |
| Drive (polarity) | non-polarized |
| Typical input current at UN | 66 mA |
| Typical response time | 5 ms ... 15 ms (depending on phase relation) |
| Typical release time range | 5 ms ... 20 ms (depending on phase relation) |
| Status display | LED (yellow) |
| Switching | |
| Contact switching type | 2 changeover contacts |
| Type of switch contact | Single contact |
| Contact material | AgNi |
| Maximum switching voltage | 250 V AC/DC |
| Minimum switching voltage | 5 V (At 24 mA) |
| Limiting continuous current | 12 A |
| Maximum inrush current | 30 A (20 ms, N/O contacts) |
| Min. switching current | 5 mA (at 24 V) |
| Interrupting rating (ohmic load) max. | 288 W (at 24 V DC) |
| 124 W (at 48 V DC) | |
| 108 W (at 60 V DC) | |
| 52 W (at 110 V DC) | |
| 48 W (at 220 V DC) | |
| 3000 VA (for 250 V AC) | |
| Switching capacity min. | 0.12 W |
| Motor load according to UL 508 | 1/2 HP, 240 V AC |
| Connection method | Plug-in connection |
| Width | 21.2 mm |
| Height | 27.5 mm |
| Depth | 35.6 mm |
| Ambient conditions | |
| Degree of protection | RT I |
| Ambient temperature (operation) | -40 °C ... 55 °C |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Corrosive gas test | |
| Identification | ISA-S71.04. G3 Harsh Group |
| EN 60068-2-60 | |
| Standards/regulations | IEC 60664 |
| IEC 61810 |
| Mounting position | any |