View larger
REL-IR2/LDP- 48DC/2X21 2903661 PHOENIX CONTACT Single relay
REL-IR2/LDP-48DC/2X21
2903661
PHOENIX CONTACT
10 Pcs.
Automation > Switching relay
Industrial Relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A single industrial relay operates as a dependable switching element that isolates sensitive electronic controllers from higher-voltage power paths within machinery. The Phoenix Contact REL-IR2/LDP-48DC/2X21 component ensures robust signal transfer and long operational life in demanding plant environments.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: Single relay
- Operating mode: 100% operating factor
- Mechanical service life: approx. 2x 10 7 cycles
- Data management status Date of last data management: 02.05.2024
- Article revision: 02
- Insulation characteristics Insulation: Basic insulation
- Overvoltage category: III
- Pollution degree: 3 (Rated voltage of 230 V)
- Service life electrical: see diagram
- Maximum power dissipation for nominal condition: 1.06 W
- Test voltage (Winding/contact): 2.5 kV rms (50 Hz, 1 min., winding/contact)
- Test voltage (Contact/contact): 2.5 kV rms (50 Hz, 1 min., contact/contact)
- Test voltage (Changeover contact/changeover contact): 2.5 kV rms (50 Hz, 1 min., changeover contact/changeover contact)
- Rated insulation voltage: 250 V AC
- Rated surge voltage: 4 kV
- Coil side Nominal input voltage U N: 48 V DC
More info
▲| Product type | Single relay |
| Operating mode | 100% operating factor |
| Mechanical service life | approx. 2x 107cycles |
| Data management status | |
| Date of last data management | 02.05.2024 |
| Article revision | 02 |
| Insulation characteristics | |
| Insulation | Basic insulation |
| Overvoltage category | III |
| Pollution degree | 3 (Rated voltage of 230 V) |
| 2 (Rated voltage of 400 V) | |
| Service life electrical | see diagram |
| Maximum power dissipation for nominal condition | 1.06 W |
| Test voltage (Winding/contact) | 2.5 kVrms(50 Hz, 1 min., winding/contact) |
| Test voltage (Contact/contact) | 2.5 kVrms(50 Hz, 1 min., contact/contact) |
| Test voltage (Changeover contact/changeover contact) | 2.5 kVrms(50 Hz, 1 min., changeover contact/changeover contact) |
| Rated insulation voltage | 250 V AC |
| Rated surge voltage | 4 kV |
| Coil side | |
| Nominal input voltage UN | 48 V DC |
| Input voltage range | 37.4 V DC ... 93.6 V DC |
| Input voltage range in reference to UN | see diagram |
| Drive and function | monostable |
| Drive (polarity) | polarized |
| Typical input current at UN | 22 mA |
| Typical response time | 13 ms |
| Typical release time | 14 ms |
| Protective circuit | Freewheeling diode |
| Status display | LED (yellow) |
| Switching | |
| Contact switching type | 2 changeover contacts |
| Type of switch contact | Single contact |
| Contact material | AgNi |
| Maximum switching voltage | 250 V AC/DC |
| Minimum switching voltage | 5 V (At 24 mA) |
| Limiting continuous current | 12 A |
| Maximum inrush current | 30 A (20 ms, N/O contacts) |
| Min. switching current | 5 mA (at 24 V) |
| Interrupting rating (ohmic load) max. | 288 W (at 24 V DC) |
| 124 W (at 48 V DC) | |
| 108 W (at 60 V DC) | |
| 52 W (at 110 V DC) | |
| 48 W (at 220 V DC) | |
| 3000 VA (for 250 V AC) | |
| Switching capacity min. | 0.12 W |
| Motor load according to UL 508 | 1/2 HP, 240 V AC |
| Connection method | Plug-in connection |
| Width | 21.2 mm |
| Height | 27.5 mm |
| Depth | 35.6 mm |
| Ambient conditions | |
| Degree of protection | RT I |
| Ambient temperature (operation) | -40 °C ... 70 °C |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Corrosive gas test | |
| Identification | ISA-S71.04. G3 Harsh Group |
| EN 60068-2-60 | |
| Standards/regulations | IEC 60664 |
| IEC 61810 |
| Mounting position | any |