PHOENIX CONTACT REL-IR2/LDP-24DC/2X21 REL-IR2/LDP- 24DC/2X21 2903660 PHOENIX CONTACT Single relay View larger
Images are for illustrative purposes only. Please refer to data sheet for details

REL-IR2/LDP- 24DC/2X21 2903660 PHOENIX CONTACT Single relay

REL-IR2/LDP-24DC/2X21

2903660

PHOENIX CONTACT

1 Pcs.

Single relay Plug-in industrial relays with power contacts, 2 inverter contacts, test key, status LED, free-flowing diode, mechanical switching position indication, polarity A1+, A2-, input voltage: 24 V DC

Automation > Switching relay
Industrial Relays

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

The REL-IR2/LDP-24DC/2X21 Phoenix Contact single relay provides reliable electromechanical switching for industrial control systems and automation switchgear. These devices facilitate safe signal isolation and power distribution across complex manufacturing machinery.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Product type: Single relay
  • Operating mode: 100% operating factor
  • Mechanical service life: approx. 2x 10 7 cycles
  • Data management status Date of last data management: 02.05.2024
  • Article revision: 02
  • Insulation characteristics Insulation: Basic insulation
  • Overvoltage category: III
  • Pollution degree: 3 (Rated voltage of 230 V)
  • Service life electrical: see diagram
  • Maximum power dissipation for nominal condition: 1.01 W
  • Test voltage (Winding/contact): 2.5 kV rms (50 Hz, 1 min., winding/contact)
  • Test voltage (Contact/contact): 2.5 kV rms (50 Hz, 1 min., contact/contact)
  • Test voltage (Changeover contact/changeover contact): 2.5 kV rms (50 Hz, 1 min., changeover contact/changeover contact)
  • Rated insulation voltage: 250 V AC
  • Rated surge voltage: 4 kV
  • Coil side Nominal input voltage U N: 24 V DC

More info

▲
Technical data

Product properties
Product typeSingle relay
Operating mode100% operating factor
Mechanical service lifeapprox. 2x 107cycles
Data management status
Date of last data management02.05.2024
Article revision02
Insulation characteristics
InsulationBasic insulation
Overvoltage categoryIII
Pollution degree3 (Rated voltage of 230 V)
2 (Rated voltage of 400 V)

Electrical properties
Service life electricalsee diagram
Maximum power dissipation for nominal condition1.01 W
Test voltage (Winding/contact)2.5 kVrms(50 Hz, 1 min., winding/contact)
Test voltage (Contact/contact)2.5 kVrms(50 Hz, 1 min., contact/contact)
Test voltage (Changeover contact/changeover contact)2.5 kVrms(50 Hz, 1 min., changeover contact/changeover contact)
Rated insulation voltage250 V AC
Rated surge voltage4 kV

Input data
Coil side
Nominal input voltage UN24 V DC
Input voltage range18.7 V DC ... 46.8 V DC
Input voltage range in reference to UNsee diagram
Drive and functionmonostable
Drive (polarity)polarized
Typical input current at UN42 mA
Typical response time13 ms
Typical release time14 ms
Protective circuitFreewheeling diode
Status displayLED (yellow)

Output data
Switching
Contact switching type2 changeover contacts
Type of switch contactSingle contact
Contact materialAgNi
Maximum switching voltage250 V AC/DC
Minimum switching voltage5 V (At 24 mA)
Limiting continuous current12 A
Maximum inrush current30 A (20 ms, N/O contacts)
Min. switching current5 mA (at 24 V)
Interrupting rating (ohmic load) max.288 W (at 24 V DC)
124 W (at 48 V DC)
108 W (at 60 V DC)
52 W (at 110 V DC)
48 W (at 220 V DC)
3000 VA (for 250 V AC)
Switching capacity min.0.12 W
Motor load according to UL 5081/2 HP, 240 V AC

Connection data
Connection methodPlug-in connection

Dimensions
Width21.2 mm
Height27.5 mm
Depth35.6 mm

Environmental and real-life conditions
Ambient conditions
Degree of protectionRT I
Ambient temperature (operation)-40 °C ... 70 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C

Approvals
Corrosive gas test
IdentificationISA-S71.04. G3 Harsh Group
EN 60068-2-60

Standards and regulations
Standards/regulationsIEC 60664
IEC 61810

Mounting
Mounting positionany

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.