View larger
SPC 16/ 8-STF-10,16 1711433 PHOENIX CONTACT Printed-circuit board connector
SPC 16/ 8-STF-10,16
1711433
PHOENIX CONTACT
50 Pcs.
Cables > Cable connector
PCB Connectors (PCC)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Built to handle heavy-duty electrical loads, the Phoenix Contact SPC 16/ 8-STF-10,16 printed-circuit board connector delivers high-current transmission capacity for demanding industrial power applications. These robust pluggable terminals guarantee secure connections in high-power drives and renewable energy systems. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Contact type (EF001587): Bus
- Number of poles (EF001391): 8
- Number of plug-in contact rows (EF006935): 1
- Modular spacing contacts (EF007326): 10.16 mm
- Modular spacing connections (EF006827): 10.16 mm
- Rated current In (EF008250): 76 A
- Rated voltage (EF000228): 1000 V
- Rated surge voltage (EF002993): 6 kV
- Over voltage category (EF006785): III
- Pollution degree (EF006786): 2
- Connectable conductor cross section solid-core (EF007337): 0.75 mm²
- Type of electric connection (EF003961): Spring clamp connection
- Connectable cable type (EF006816): Tubular cable
- Material of contact surface (EF004020): Silver
- Material contact (EF007544): Copper
- Material insulation body (EF007543): Polyamide (PA)
More info
▲Key Commercial Data
| Orderkey | 1711433 |
|---|---|
| Packing unit | 50 pc |
| Note | Made to Order (non-returnable) |
| Catalog page | Page 563 (C-1-2013) |
| GTIN | 4046356081184 |
| Weight per Piece (excluding packing) | 67.900 g |
| Custom tariff number | 85366990 |
| Country of origin | IN (India) |
General
| Range of articles | SPC 16/..-STF |
|---|---|
| Number of positions | 8 |
| Connection method | Push-in spring connection |
| Insulating material group | I |
| Rated surge voltage (III/3) | 8 kV |
| Rated surge voltage (III/2) | 8 kV |
| Rated surge voltage (II/2) | 6 kV |
| Rated voltage (III/3) | 1000 V |
| Rated voltage (III/2) | 1000 V |
| Rated voltage (II/2) | 1000 V |
| Connection in acc. with standard | EN-VDE |
| Nominal current IN | 76 A |
| Nominal cross section | 16 mm² |
| Maximum load current | 76 A |
| Insulating material | PA |
| Flammability rating according to UL 94 | V0 |
| Stripping length | 18 mm |
Connection data
| Conductor cross section solid min. | 0.75 mm² |
|---|---|
| Conductor cross section solid max. | 16 mm² |
| Conductor cross section flexible min. | 0.75 mm² |
| Conductor cross section flexible max. | 16 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve min. | 0.75 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve max. | 16 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve min. | 0.75 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve max. | 10 mm² |
| Conductor cross section AWG min. | 18 |
| Conductor cross section AWG max. | 4 |
| 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, min. | 0.75 mm² |
| 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max. | 4 mm² |
| Minimum AWG according to UL/CUL | 20 |
| Maximum AWG according to UL/CUL | 4 |
Standards and Regulations
| Connection in acc. with standard | EN-VDE |
|---|---|
| CUL | |
| Flammability rating according to UL 94 | V0 |
Environmental Product Compliance
| China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
|---|---|
| No hazardous substances above threshold values |