View larger
FKCT 2,5/15-ST-5,08 1902246 PHOENIX CONTACT Printed-circuit board connector
FKCT 2,5/15-ST-5,08
1902246
PHOENIX CONTACT
50 Pcs.
Cables > Cable connector
PCB Connectors (PCC)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Phoenix Contact FKCT 2,5/15-ST-5,08 1902246 printed-circuit board connector features an intuitive spring-clamp design for fast, secure wire attachment. This category of connector is heavily relied upon in industrial control environments to simplify maintenance and ensure continuous signal integrity. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Contact type (EF001587): Bus
- Number of poles (EF001391): 15
- Number of plug-in contact rows (EF006935): 1
- Modular spacing contacts (EF007326): 5.08 mm
- Modular spacing connections (EF006827): 5.08 mm
- Rated current In (EF008250): 12 A
- Rated voltage (EF000228): 320 V
- Rated surge voltage (EF002993): 4 kV
- Over voltage category (EF006785): III
- Pollution degree (EF006786): 2
- Connectable conductor cross section solid-core (EF007337): 0.2 mm²
- Type of electric connection (EF003961): Spring clamp connection
- Connectable cable type (EF006816): Tubular cable
- Material of contact surface (EF004020): Tin
- Material contact (EF007544): Copper
- Material insulation body (EF007543): Polyamide (PA)
More info
▲Key Commercial Data
| Orderkey | 1902246 |
|---|---|
| Packing unit | 50 pc |
| Note | Made to Order (non-returnable) |
| Catalog page | Page 277 (C-1-2013) |
| GTIN | 4017918187248 |
| Weight per Piece (excluding packing) | 24.780 g |
| Custom tariff number | 85366990 |
| Country of origin | DE (Germany) |
General
| Range of articles | FKCT 2,5/..-ST |
|---|---|
| Number of positions | 15 |
| Connection method | Push-in spring connection |
| Insulating material group | I |
| Rated surge voltage (III/3) | 4 kV |
| Rated surge voltage (III/2) | 4 kV |
| Rated surge voltage (II/2) | 4 kV |
| Rated voltage (III/3) | 320 V |
| Rated voltage (III/2) | 320 V |
| Rated voltage (II/2) | 630 V |
| Connection in acc. with standard | EN-VDE |
| Nominal current IN | 12 A |
| Nominal cross section | 2.5 mm² |
| Maximum load current | 12 A |
| Insulating material | PA |
| Flammability rating according to UL 94 | V0 |
| Internal cylindrical gage | A2 |
| Stripping length | 10 mm |
Connection data
| Conductor cross section solid min. | 0.2 mm² |
|---|---|
| Conductor cross section solid max. | 2.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve min. | 0.25 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve max. | 2.5 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve min. | 0.25 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve max. | 2.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 12 |
| 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, min. | 0.5 mm² |
| 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max. | 1.5 mm² |
| Minimum AWG according to UL/CUL | 26 |
| Maximum AWG according to UL/CUL | 12 |
Standards and Regulations
| Connection in acc. with standard | EN-VDE |
|---|---|
| CUL | |
| Flammability rating according to UL 94 | V0 |
Environmental Product Compliance
| China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
|---|---|
| No hazardous substances above threshold values |